D-Link DXS-3600-32S Hardware Installation Manual Download Page 12

DXS-3600-32S 10GbE Layer 2/3 Switch Hardware Installation Guide

5

For a complete list of SFP/SFP+/WDM transceivers, that are compatible with this switch, refer to the “

Product 

Specifications

” section in 

Appendix A

.

Rear Panel Description

Located on the rear panel of the switch are 

two power supply module slots

 and 

three fan module slots

One power 

supply module

 and 

three fan modules

 are included in the package for this switch. Any additional power supply 

module or fan module needs to be bought separately. This switch also supports the use of a DC power supply module.

Figure 1-3 Rear panel view of the DXS-3600-32S

Power Supply Module

Connect the one end of the AC power cord supplied to the AC power connector and the other end into a properly 
grounded electrical outlet. The switch will automatically adjust the power setting to adapt to any voltage supply in the 
range from 100~240VAC at 50~60Hz. 

In addition, an optional second power supply module can be plugged into the second power supply connector slot 
displayed above. When the primary power connection fails, the secondary power connection will take over all the 
power immediately and automatically. The primary and secondary power supply can be either AC supplied or DC 
supplied, depending on the power supply module inserted.

The power supply modules are hot-swappable, meaning, that they can be inserted and removed while the switch is 
powered on. This feature enhances the reliability of this switch. However, in the event that a power failure might occur 
in the environment and no UPS is used, as a precaution, unplug the power cord from the switch. After the return of 
power, you can plug the power cord back into the Switch’s power connector.

Fan Module

The fan modules on this switch can provide 

front-to-back

 or 

back-to-front

 airflow depending on type on fan module 

installed. Another unique smart fan feature is that fans are capable to 

automatically ajust their speed 

depending on 

the IC sensor reading of the temperature required. This feature is so sensitive that it can even 

adjust the speed of the 

fan

 to accurately control the internal temperature.

Side Panel Description

Located on the side panels of the switch are 

heat and fan vents

 that are used to dissipate heat. Do not block these 

openings. Leave at least 4 inches of space at the rear and sides of the switch for proper ventilation. Be reminded that 
without proper heat dissipation and air circulation, system components might overheat, which could lead to system 
failure or even severely damage components.

Summary of Contents for DXS-3600-32S

Page 1: ......

Page 2: ...not installed and used in accordance with this manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which...

Page 3: ...e the brackets Bold Font This font is generally used to put emphasis on a key subject in a sentence through out this manual This font is also used to represent the physical CLI command used when explaining a topic Boldface Typewriter Font This font is used to indicate CLI command examples used in this document Initial capital letter The use of initial capital letters indicates that a referral to a...

Page 4: ... AC powered option intended for your system purchase a power cable that is approved for use in your country The power cable must be rated for the product and for the voltage and current marked on the product s electrical ratings label The voltage and current rating of the cable should be greater than the ratings marked on the product To help prevent electric shock plug the system and peripheral po...

Page 5: ...harge Static electricity can harm delicate components inside the system To prevent static damage discharge static electricity from your body before touching any of the electronic components such as the microprocessor This can be done by periodically touching an unpainted metal surface on the chassis The following steps can also be taken prevent damage from electrostatic discharge ESD When unpackin...

Page 6: ...ack 8 Installing Transceivers into the Transceiver Ports 9 Installing Power Modules into the Power Module Ports 10 Installing an AC Power Module 10 Installing a DC Power Module 11 Installing Fan Modules into the Fan Module Ports 13 Switch Connections 14 Switch to an End Node 14 Switch to another Switch 14 Switch to a Server 15 Switch Stacking 15 Switch Management 16 Management Options 16 Connectin...

Page 7: ...DXS 3600 32S 10GbE Layer 2 3 Switch Hardware Installation Guide Appendix C Module Specifications and Cable Lengths 31 ...

Page 8: ...curity features designed to protect your network from malicious attacks SSH SSL encrypted management guarantee secure private configuration and monitoring when using the Graphical User Interface GUI and Command Line CLI IP MAC Port binding prevents unauthorized devices from accessing network resources and also acts as an anti spoofing tool IEEE 802 1X ports and MAC based authentication help provid...

Page 9: ...rol List ACL Time Based ACL Traffic Segmentation Port Security Broadcast Multicast DLF Storm Control BPDU Attack Protection DoS Prevention 802 1X RADIUS Access Authentication Control AAA Guest VLAN User Account Privilege for Management Access RADIUS Accounting Address Resolution Protocol ARP Link Layer Discovery Protocol LLDP Static Routing Web based Graphical User Interface Web GUI Command Line I...

Page 10: ... Routing MIB PIM MIB for IPv4 RADIUS Accounting Client MIB Ping MIB Trace out MIB L2 Specific MIB L3 Specific MIB OSPFv2 MIB VRRP MIB Private MIB Entity MIB LED Description Power1 Power2 This LED will light solid green after the Switch has been powered on successfully This LED will light solid orange if the Switch s power supply fails This LED will be off when the Switch is no longer receiving pow...

Page 11: ...o 12 can be assigned manually by the user or auto matically by the system The letter H will be displayed if this switch is the master switch in the stack The letter h will be displayed if this switch is the backup master switch in the stack The letter E will be displayed if there was an error in the system s self test The letter G will be displayed when the Safeguard engine entered the exhausted m...

Page 12: ...primary and secondary power supply can be either AC supplied or DC supplied depending on the power supply module inserted The power supply modules are hot swappable meaning that they can be inserted and removed while the switch is powered on This feature enhances the reliability of this switch However in the event that a power failure might occur in the environment and no UPS is used as a precauti...

Page 13: ...DXS 3600 32S 10GbE Layer 2 3 Switch Hardware Installation Guide 6 Figure 1 4 Side panels of the DXS 3600 32S ...

Page 14: ...rating ranges Install the switch in a site free from strong electromagnetic field generators such as motors vibration dust and direct exposure to sunlight Installing the Switch without a Rack This section is used to guide the user through installing the switch in an area other than a switch rack Attach the rubber feet included to the bottom of the switch Take note that there should be marked block...

Page 15: ...k using the provided mounting brackets Use the following diagram as a guide Figure 2 2 Fasten mounting brackets on the Switch How to install the mounting brackets onto the switch Figure above and onto the rack Figure below 1 Fasten the mounting brackets A and B to the sides of the switch using the screws provided as seen in the figure above 2 Fasten the mounting bracket C in the appropriate open s...

Page 16: ...used to connect various other networking devices to this switch that do not support the standard copper wiring connection These ports are generally used to connect this switch to networking devices that can only be accessed via an optical fiber connection and is normally used for a connection that spans greater distances The maximum distance that the copper wiring connection can reach is 100 meter...

Page 17: ...of this switch support two types of power supply modules AC Power Supply Module DXS 3600 PWR FB A 300W AC power supply tray with front to back air flow DXS 3600 PWR BF A 300W AC power supply tray with back to front air flow DC Power Supply Module DXS 3600 PWRDC FB A 300W DC power supply tray with front to back air flow DXS 3600 PWRDC BF A 300W DC power supply tray with back to front air flow Insta...

Page 18: ...odules are hot swappable meaning that they can be inserted and removed while the switch is powered on This feature enhances the reliability of this switch Installing a DC Power Module This switch supports a unique dual power input feature Connect the one end of the DC power cord supplied to a DC power source 48VDC 5 2A that will be activated when the AC power is not working Please make sure that c...

Page 19: ...e power source has been restored plug the switch s power back in Before connecting the DC power cable to the DC power input socket on the switch the DC power cable must be properly connected to DC source at your facility by a qualified licensed electrician The DC power cable s wire size must be 18AWG Connect the DC power cable to a DC main circuit breaker rated no greater than 15A If you are insta...

Page 20: ...a 1 4 inch flat blade Ground additional hardware appropriately to the earth ground connection at your site Installing Fan Modules into the Fan Module Ports Located on the rear panel of this switch there are three fan module ports Figure 2 9 Installing a Fan Module The user can easily remove and insert fan modules into these ports NOTE All fan modules installed in this switch should support the sam...

Page 21: ...Link Act light will illuminate and blink to indicate that packet activity is taking place on that port The diagram below display a typical end node connected to the Switch Figure 3 1 Connecting the Switch to an end node Switch to another Switch Another popular configuration is to connect this switch to another switch or hub This network typography is considered when one Switch does not have enough...

Page 22: ...ing This switch supports physical stacking where a set of four switches can be combined to be managed by one IP address Each switch that has the DXS 3600 EM Stack module installed has two stacking slots located at the front of the device which can be used to connect these ports together using copper or fiber stacking cables sold separately in a ring topology As shown in the figure below the stacke...

Page 23: ...ects to generate statistics and counters Web based Management Interface After successfully installing the switch the user can configure the switch monitor the LED panel and display statistics graphically using a Web browser such as Microsoft Internet Explorer version 5 5 and later Mozilla Firefox version 2 0 and later Safari version 4 0 and later and Google Chrome version 6 0 and later Connecting ...

Page 24: ...stop bit and no parity Set flow control to none Figure 4 1 COM1 Properties Port Settings Under Properties select VT100 for Emulation mode Select Terminal keys for Function Arrow and Ctrl keys Make sure to use Terminal keys not Windows keys are selected Figure 4 2 COM1 Properties General Settings NOTE When using HyperTerminal with the Microsoft Windows 2000 operating system ensure that Windows 2000...

Page 25: ...ds after the command prompt DXS 3600 appears Creating a User Account As you will have noticed by now is that this switch does not have a default username and password One of the first and most important tasks will be to create user accounts Logging in using a predefined administrator level username will give the user privileged access to the Switch s management software Also this will prevent unau...

Page 26: ...s 0 0 0 0 and should thus be configured prior to installation You can change the switch s default IP address to fit into your networking address range The Switch is also assigned a unique MAC address by the factory This MAC address cannot be changed and can be found by entering the command show system info into the command line interface in the Privileged EXEC mode as shown below Figure 4 6 The sh...

Page 27: ...IP address can also automatically be obtained by using the BOOTP or DHCP protocol Connecting using SNMP The switch can be managed with an SNMP compatible console program The Simple Network Management Protocol SNMP operates on the Application Layer of the OSI model and is designed specifically for managing and monitoring network devices The SNMP agent decodes the incoming SNMP messages and responds...

Page 28: ...stations to retrieve and modify MIB objects Figure 4 9 To view the SNMP community strings SNMPv3 uses a more sophisticated authentication process that is separated into two parts 1 The first part is to maintain a list of users and their attributes that are allowed to act as SNMP managers 2 The second part describes what each user on that list can do as an SNMP manager The switch allows groups of u...

Page 29: ...g the MIB Object Identifier MIB values can be either read only or read write Connecting using the Web User Interface All software functions of the switch can be managed configured and monitored via the embedded Web based HTML interface This can be done from any remote station on the network through a standard web browser such as Internet Explorer version 5 5 and later Mozilla Firefox version 2 0 a...

Page 30: ...name or Password click OK to proceed This will open the Web based User Interface The switch management features available in the Web based manager are explained below Areas of the User Interface After a successful connection to the Web User Interface has been made the following page should be displayed Figure 4 12 Main Web Manager window ...

Page 31: ...the hardware features run ning on this switch Some of the features that can be monitored here are the Device Information Temperature CPU Usage System Log Fan Status Memory Usage and Network Traffic Utilization In the Management window the user can also Download Upload Firmware Configuration files to and from this switch AREA 2 This area displays a graphical real time image of the front panel of th...

Page 32: ...Address Table 128K MAC Address Table with 1K Static MAC Addresses Power Consumption 115 3 Watt Without expansion module IP Routing Tables IPv4 IPv6 16K Entries IPv6 8K Entries IP Host Tables IPv4 8K Entries Jumbo Frame Size 12KBytes Transmission Method Store and forward Cut and through Forwarding Rates 14 880pps 10M 148 800pps 100M 1 488 000pps 1G 14 880 000pps 10G Physical Stacking Supports up to...

Page 33: ...DGS 712 1000BASE T Copper 100m WDM Ports 1000Mbps WDM Transceivers Supported DEM 330T R 1000BASE BX Single Mode 10km DEM 331T R 1000BASE BX Single Mode 40km SFP Ports 10Gbps Compliant to following standards IEEE 802 3ae compliance IEEE 802 3aq compliance SFP Transceivers Supported DEM 431XT 10GBASE SR w o DDM 80m OM1 OM2 MMF 300m OM3 MMF DEM 431XT DD 10GBASE SR DDM 80m OM1 OM2 MMF 300m OM3 MMF DEM...

Page 34: ...king Fan failure SD Green Light on Solid SD plugged in Light blinking Busy reading writing Light off No link Red Light on Solid Read Write failure Stacking ID 7 segment LED Green Light on 1 12 Stacking number displayed Light on H Stacking Master Light on h Stacking Backup Master Light on E System self test error Light on G Safeguard Engine in exhausted mode LED Per Port 10 100 1000Mbps Link Act Sp...

Page 35: ...device at any of the ports Light blinking When there is reception or transmission of data occur ring at 10Gbps Orange Light on Solid When there is a secure con nection or link to 1000Mbps Ethernet device at any of the ports Light blinking When there is reception or transmission of data occur ring at 1000Mbps Off Light off No link LED Indicators Location LED Color Status Description ...

Page 36: ...or matching cable pin assignment The following diagrams and tables show the standard RJ 45 receptacle connector and their pin assignments Figure 6 1 The standard RJ 45 port and connector RJ 45 Pin Assignments Contact MDI X Port MDI II Port 1 RD receive TD transmit 2 RD receive TD transmit 3 TD transmit RD receive 4 1000BASE T 1000BASE T 5 1000BASE T 1000BASE T 6 TD transmit RD receive 7 1000BASE T...

Page 37: ...The following diagrams and tables show the standard Console to DJ 45 receptacle connector and their pin assignments Figure 6 2 Console to RJ 45 Cable Console RJ 45 Pin Assignments Contact Console DB9 RS232 RJ 45 1 Not Used Not Used 2 RXD Not Used 3 TXD TXD 4 Not Used GND 5 GND shared GND 6 Not Used RXD 7 Not Used Not Used 8 Not Used Not Used ...

Page 38: ...r module 1000BASE SX Multi mode fiber module 1000BASE LH Single mode fiber module 1000BASE ZX Single mode fiber module 10km 550m 2km 50km 80km 1000BASE T Category 5e UTP Cable 100m 100BASE TX Category 5 UTP Cable 100 Mbps 100m 10BASE T Category 3 4 or 5 UTP Cable 10 Mbps 100m DEM 310GT 1000BASE LX Single mode 10km DEM 311GT 1000BASE SX Multi mode 550m DEM 312GT2 1000BASE SX Multi mode 2km DEM 314G...

Page 39: ...iquidators expressly disclaim their warranty obligation pertaining to the product and in that case the product is being sold As Is without any warranty whatsoever including without limitation the Limited Warranty as described herein notwithstanding anything stated herein to the contrary Submitting A Claim The customer shall return the product to the original purchase point based on its return poli...

Page 40: ...opyright Statement No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc as stipulated by the United States Copyright Act of 1976 and any amendments thereto Contents are subject to change without...

Page 41: ...Registration Register your D Link product online at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights ...

Page 42: ...e warranty period on this product U S and Canadian customers can contact D Link technical support through our website or by phone Tech Support for customers within the United States D Link Technical Support over the Telephone USA 877 DLINK 55 877 354 6555 D Link Technical Support over the Internet http support dlink com Tech Support for customers within Canada D Link Technical Support over the Tel...

Page 43: ...2 00pm 0 05ppm peak 0 045ppm off peak Times Internet http www dlink co uk ftp ftp dlink co uk Technische Unterstützung Deutschland Web http www dlink de Telefon 49 0 1805 2787 0 14 pro Minute Zeiten Mo Fr 09 00 17 30 Uhr Österreich Web http www dlink at Telefon 43 0 820 480084 0 116 pro Minute Zeiten Mo Fr 09 00 17 30 Uhr Schweiz Web http www dlink ch Telefon 41 0 848 331100 0 08 CHF pro Minute Ze...

Page 44: ...r minuut Tech Support for customers within Belgium www dlink be 033039971 0 175per minuut spitsuren 0 0875per minuut daluren Technische ondereuning voor klanten in Luxemburg www dlink be 32 70 66 06 40 Asistencia Técnica Asistencia Técnica Telefónica de D Link 34 902 30 45 45 0 067 min De Lunes a Viernes de 9 00 a 19 00 http www dlink es Supporto tecnico Supporto Tecnico dal lunedì al venerdì dall...

Page 45: ...9 00 do 17 00 Volání je zpoplatněno dle příslušných tarifů Vašeho operátora Technikai Támogatás Tel 06 1 461 3001 Fax 06 1 461 3004 Land Line 14 99 HUG min Mobile 49 99 HUF min email support dlink hu URL http www dlink hu Teknisk Support D Link Teknisk Support over Internett http www dlink no D Link Teknisk telefonsupport 815 69 755 Hverdager 08 00 17 00 Teknisk Support D Link teknisk support over...

Page 46: ...ter Κεφαλληνίας 64 11251 Αθήνα Τηλ 210 86 11 114 Δευτέρα Παρασκευή 09 00 17 00 Φαξ 210 8611114 http www dlink gr support Assistência Técnica Assistência Técnica da D Link na Internet http www dlink pt e mail soporte dlink es Teknisk Support D Link Teknisk Support via Internet http www dlink se D Link Teknisk Support via telefon 0770 33 00 35 Vardagar 08 00 17 00 ...

Page 47: ...k biz hr Tehnična podpora Zahvaljujemo se vam ker ste izbrali D Link proizvod Za vse nadaljnje informacije podporo ter navodila za uporabo prosimo obiščite D Link ovo spletno stran www dlink eu www dlink biz sl Suport tehnic Vă mulţumim pentru alegerea produselor D Link Pentru mai multe informaţii suport şi manuale ale produselor vă rugăm să vizitaţi site ul D Link www dlink eu www dlink ro ...

Page 48: ...day 9 30AM to 6 30PM Thursdays 9 30AM to 2 00 PM E mail Support sa dlink me com D Link Middle East Dubai U A E Plot No S31102 Jebel Ali Free Zone South P O Box 18224 Dubai U A E Tel 971 4 8809022 Fax 971 4 8809066 8809069 Technical Support 971 4 8809033 General Inquiries info me dlink me com Tech Support support me dlink me com Egypt 1 Makram Ebeid Street City Lights Building Nasrcity Cairo Egypt ...

Page 49: ...one 212 663 72 73 24 Email support na dlink me com Lebanon RMA center Dbayeh Lebanon PO Box 901589 Tel 961 4 54 49 71 Ext 14 Fax 961 4 54 49 71 Ext 12 Email taoun dlink me com Bahrain Technical Support 973 1 3332904 Kuwait Technical Support 965 22453939 965 22453949 Türkiye Merkez İrtibat Ofisi Ayazağa Maslak yolu Erdebil Cevahir İş Merkezi No 5 A Ayazağa Maslak İstanbul Tel 90 212 2895659 Ücretsi...

Page 50: ...исимости 169 БЦ XXI Век Тел 375 17 218 13 65 E mail minsk dlink ru Казахстан 050008 г Алматы ул Курмангазы дом 143 уг Муканова Тел факс 7 727 378 55 90 E mail almaty dlink ru Узбекистан 100015 г Ташкент ул Нукусская 89 Тел Факс 998 71 120 3770 150 2646 E mail tashkent dlink ru Армения 0038 г Ереван ул Абеляна 6 1 4 этаж Тел Факс 374 10 398 667 E mail erevan dlink ru Грузия 0162 г Тбилиси проспект ...

Page 51: ...s siguientes teléfonos de D Link PAIS NUMERO Argentina 0800 12235465 Chile 800 260200 Colombia 01800 9525465 Costa Rica 0800 0521478 Ecuador 1800 035465 El Salvador 800 6335 Guatemala 1800 8350255 México 01800 1233201 Panamá 011 008000525465 Perú 0800 00968 Venezuela 0800 1005767 Soporte Técnico de D Link a través de Internet Horario de atención Soporte Técnico en www dlinkla com e mail soporte dl...

Page 52: ...br Acionar Garantia para 4 ou mais equipamentos Telefones São Paulo 11 2755 6950 GO 4052 1850 Ligação local Nordeste 0800 7024104 Demais Estados 4062 1850 Ligação local Apenas Modems ADSL Garantia diferenciada vendida pela internet Agilidade e tranquilidade para suas atividades Conheça http garantiapremium dlink com br Atendimento disponível das 9h as 21h de segunda a sexta feira e aos sábados das...

Page 53: ...方式與D Link台灣 地區技術支援工程師聯絡 D Link 免付費技術諮詢專線 0800 002 615 服務時間 週一至週五 早上9 00到晚上9 00 不含周六 日及國定假日 網 站 http www dlink com tw 電子郵件 dssqa_service dlink com tw 如果您是台灣地區以外的用戶 請參考D Link網站全球各地 分公司的聯絡資訊以取得相關支援服務 產品保固期限 台灣區維修據點查詢 請參考以下網頁說明 http www dlink com tw 產品維修 使用者可直接送至全省聯強直營維修站或請洽您的原購買經銷商 ...

Page 54: ...okumentasi pengguna dapat diperoleh pada situs web D Link Dukungan Teknis untuk pelanggan Dukungan Teknis D Link melalui telepon Tel 62 21 5731610 Dukungan Teknis D Link melalui Internet Email support dlink co id Website http support dlink co id ...

Page 55: ...Technical Support この度は弊社製品をお買い上げいただき 誠にありがとうご ざいます 下記弊社 Web サイトからユーザ登録及び新製品登録を 行っていただき ダウンロードサービスにて サポート情報 ファームウェア ユーザマニュアルを ダウンロードすることができます ディーリンクジャパン Web サイト URL http www dlink jp com ...

Page 56: ...技术支持 办公地址 北京市东城区北三环东路 36 号 环球贸易中心 B 座 26F 02 05 室 邮编 100013 技术支持中心电话 8008296688 028 66052968 技术支持中心传真 028 87300889 各地维修中心地址请登陆官方网站查询 网址 http www dlink com cn 办公时间 周一到周五 早09 00到晚18 00 ...

Page 57: ... site 1 employee 2 9 10 49 50 99 100 499 500 999 1000 or more 3 What network protocol s does your organization use XNS IPX TCP IP DECnet Others_____________________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Cisco Network Banyan Vines DECnet Pathwork Windows NT Windows 98 Windows 2000 ME Windows...

Page 58: ......

Reviews: