DXS-3600-32S 10GbE Layer 2/3 Switch Hardware Installation Guide
5
For a complete list of SFP/SFP+/WDM transceivers, that are compatible with this switch, refer to the “
Product
Specifications
” section in
Appendix A
.
Rear Panel Description
Located on the rear panel of the switch are
two power supply module slots
and
three fan module slots
.
One power
supply module
and
three fan modules
are included in the package for this switch. Any additional power supply
module or fan module needs to be bought separately. This switch also supports the use of a DC power supply module.
Figure 1-3 Rear panel view of the DXS-3600-32S
Power Supply Module
Connect the one end of the AC power cord supplied to the AC power connector and the other end into a properly
grounded electrical outlet. The switch will automatically adjust the power setting to adapt to any voltage supply in the
range from 100~240VAC at 50~60Hz.
In addition, an optional second power supply module can be plugged into the second power supply connector slot
displayed above. When the primary power connection fails, the secondary power connection will take over all the
power immediately and automatically. The primary and secondary power supply can be either AC supplied or DC
supplied, depending on the power supply module inserted.
The power supply modules are hot-swappable, meaning, that they can be inserted and removed while the switch is
powered on. This feature enhances the reliability of this switch. However, in the event that a power failure might occur
in the environment and no UPS is used, as a precaution, unplug the power cord from the switch. After the return of
power, you can plug the power cord back into the Switch’s power connector.
Fan Module
The fan modules on this switch can provide
front-to-back
or
back-to-front
airflow depending on type on fan module
installed. Another unique smart fan feature is that fans are capable to
automatically ajust their speed
depending on
the IC sensor reading of the temperature required. This feature is so sensitive that it can even
adjust the speed of the
fan
to accurately control the internal temperature.
Side Panel Description
Located on the side panels of the switch are
heat and fan vents
that are used to dissipate heat. Do not block these
openings. Leave at least 4 inches of space at the rear and sides of the switch for proper ventilation. Be reminded that
without proper heat dissipation and air circulation, system components might overheat, which could lead to system
failure or even severely damage components.