As with any electric device, you should place the equipment where it
will   not   be   subjected   to   extreme   temperatures,   humidity,   or
electromagnetic interference. Specifically, the site you select should
meet the following requirements:

A. The ambient temperature should be between 32 and 104 degrees
Fahrenheit (0 to 40 degrees Celsius).
B.   The   relative   humidity   should   be   less   than   90   percent,
non-condensing.
C.   Surrounding   electrical   devices   should   not   exceed   the
electromagnetic field (RFC) standards for IEC 801-3, Level 2 (3V/M)
field strength.
D. Make sure that the equipment receives adequate ventilation. Do
not block the ventilation holes on each side of the media converter or
the fan exhaust port on the side or rear of the equipment.
E. The power outlet should be within 1.8 meters of the switch.

C

ONNECTING

 

TO

 P

OWER

1. This Converter is a plug-and-play device.

2. Connect the supplied AC to DC power adaptor with a power voltage
of 12Vdc/0.5Amp to the DC-Jack on the converter, and then attach the
plug   into   a   standard   AC   outlet   with   a   voltage   range   from   100   to
240 Vac.

3

Summary of Contents for DMC-805X

Page 1: ...DMC 805X 10G CX4 To 10G SFP Media Converter Медиаконвертер с 1 портом 10GBase CX4 и 1 портом 10GBase X SFP Quick Installation Guide Краткое руководство по установке RECYCLABLE 1 ...

Page 2: ...t the switch its components making network connections and technical specifications please refer to the User Manual PACKAGE CONTENTS These are the items included with your DMC 805X purchase DMC 805X Media Converter Power Adapter User Manual Warranty Certificate If any of the above items are damaged or missing please contact your local reseller for replacement Using a power supply with a different ...

Page 3: ...unding electrical devices should not exceed the electromagnetic field RFC standards for IEC 801 3 Level 2 3V M field strength D Make sure that the equipment receives adequate ventilation Do not block the ventilation holes on each side of the media converter or the fan exhaust port on the side or rear of the equipment E The power outlet should be within 1 8 meters of the switch CONNECTING TO POWER ...

Page 4: ...SLIDING SWITCH There is a sliding switch for duplex mode setting for fiber port Refer to the table below for more details On LLR Enable Off LLR Disable Switch 1 On LLR enable Off LLR disable default 4 ...

Page 5: ...tall the converter onto a carrier supplied with the chassis Step 1 Unscrew the carrier from the desired expansion slot on the chassis Step 2 Remove the screw on the converter as shown below Step 3 Fit the converter onto the carrier and use the screw to secure it 5 Unscrew and pull out the media converter board ...

Page 6: ... the converter LEDs State Indication Power PWR Lights on Power on Lights off Power off CX4 Lights on Linking Lights Blinking Data transmitting and receiving Lights off Not Linking SPF Lights on Linking Lights Blinking Data transmitting and receiving Lights off Not Linking 6 ...

Page 7: ...тствовать параметрам указанным в технических характеристиках устройства Устройство должно находиться на расстоянии не ближе 1 8 м от электрической розетки Не вскрывайте корпус устройства Перед очисткой устройства от загрязнений и пыли отключите питание устройства Удаляйте пыль с помощью влажной салфетки Не используйте жидкие аэрозольные очистители или магнитные статические устройства для очистки И...

Page 8: ...диаконвертере его компонентах настройке подключения к сети и технических характеристиках обращайтесь к руководству пользователя КОМПЛЕКТ ПОСТАВКИ Медиаконвертер DMC 805X Адаптер питания Эксплуатационная документация Гарантийный талон Если что либо отсутствует обратитесь к Вашему поставщику Использование источника питания с другими характеристиками и напряжением может повлечь выход из строя устройс...

Page 9: ... В 0 5 А входящий в комплект поставки к разъему питания на задней панели медиаконвертера затем вставьте вилку в стандартную электрическую розетку с диапазоном напряжений от 100 до 240 В переменного тока ПЕРЕКЛЮЧАТЕЛЬ Плата медиаконвертера DMC 805X оснащена переключателем работы оптического порта On LLR включен Off LLR отключен 9 ...

Page 10: ...медиаконвертера в слот шасси DMC 1000 выполните следующие действия Шаг 1 Снимите корпус медиаконвертера Шаг 2 Открутите винт и снимите фальш панель с нужного слота расширения Шаг 3 Установите медиаконвертер в шасси и закрепите его 10 ...

Page 11: ...икаторы Состояние Описание Питание PWR Горит Питание включено Не горит Питание выключено CX4 Горит Сетевое соединение установлено Мигает Передача и прием данных Не горит Нет соединения SPF Горит Сетевое соединение установлено Мигает Передача и прием данных Не горит Нет соединения 11 ...

Page 12: ...нкции LLR Режим коммутации Store and forward Поддержка метода обратного давления и функции управления потоком IEEE 802 3x Коммутация на скорости канала Индикаторы состояния на передней панели Работа в автономном режиме или установка в шасси DMC 1000 Питание 12 В 0 5 А внешний адаптер питания Размеры Д х Ш х В 120 x 88 x 25 мм Вес 0 29 кг Температура Рабочая От 0 до 40 C С Хранения От 10 до 70 C С ...

Page 13: ...13 ...

Reviews: