DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
207
22-3
transceiver-monitoring action shutdown
This command is used to shut down a port from an alarm or a warning of an abnormal status.
Use the
no
form of this command to disable the shutdown action.
transceiver-monitoring action shutdown {alarm | warning}
no transceiver-monitoring action shutdown
Parameters
alarm
Specifies to shut down a port when alarm events occur.
warning
Specifies to shut down a port when warning events occur.
Default
By default, this option is disabled.
Command Mode
Interface Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
This command is available for physical port interface configuration.
The configuration can select to shut down a port on an alarm event or warning event or not to shut
down on either of them. When the monitoring function is enabled, an alarm event occurs when the
parameters, being monitored, go higher than the high alarm threshold or go lower than the low alarm
threshold. A warning event occurs when the parameters being monitored go higher than the high
warning threshold or go lower than the low warning threshold.
The port shutdown feature is controlled by the Error Disable module without a recover timer. Users
can manually recover the port by using the
shutdown
command and then the
no shutdown
command.
Example
This example shows how to configure the shutdown interface eth3/0/1 when an alarm event is
detected.
Switch# configure terminal
Switch(config)# interface eth3/0/1
Switch(config-if)# transceiver-monitoring action shutdown alarm
Switch(config-if)#
22-4
transceiver-monitoring bias-current
This command is used to configure the thresholds of the bias current for a specified port.
Use the
no
form of this command to remove the configuration.
transceiver-monitoring bias-current INTERFACE-ID {high | low} {alarm | warning} VALUE
no transceiver-monitoring bias-current INTERFACE-ID {high | low} {alarm | warning}
Parameters
INTERFACE-ID
Specifies the interface to modify.
high
Specifies the high threshold, when the operating parameter rises
above this value. It indicates an abnormal status.
Summary of Contents for DGS-510
Page 1: ...1 ...
Page 287: ...DGS 1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide 284 ...