![D-Link DGS-510 Reference Manual Download Page 131](http://html.mh-extra.com/html/d-link/dgs-510/dgs-510_reference-manual_78049131.webp)
DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
128
Switch# show ipv6 interface vlan2
vlan2 is up, Link status is down
IPv6 is enabled,
link-local address:
FE80::201:1FF:FE02:305
Global unicast address:
200::2/64 (DHCPv6 PD)
IP MTU is 1500 bytes
RA advertised retransmit interval is 0 milliseconds
Switch#
This example shows how to display brief IPv6 interface information.
Switch# show ipv6 interface brief
vlan1 is up, Link status is up
FE80::201:1FF:FE02:304
vlan2 is up, Link status is down
FE80::201:1FF:FE02:305
200::2
vlan3 is up, Link status is down
FE80::201:1FF:FE02:306
Total Entries: 3
Switch#
10-17
show ipv6 neighbors
This command is used to display IPv6 neighbor information.
show ipv6 neighbors [INTERFACE-ID] [IPV6-ADDRESS]
Parameters
IPV6-ADDRESS
Specifies the IPv6 address to display its IPv6 neighbor cache entry.
INTERFACE-ID
Specifies the interface to display IPv6 neighbor cache entry.
Default
None.
Command Mode
EXEC Mode or Any Configuration Mode.
Command Default Level
Level: 1.
Usage Guideline
Use this command to display the IPv6 neighbor cache entry.
Summary of Contents for DGS-510
Page 1: ...1 ...
Page 287: ...DGS 1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide 284 ...
Page 321: ...DGS 1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide 318 ...
Page 493: ...DGS 1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide 490 ...
Page 733: ...DGS 1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide 730 ...