DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide
28
Performance
DGS-1210-52MPP/ME: 77.4 Mpps
MAC Address Learning
Automatic update. Supports 16K MAC address.
DRAM
256 MB – DDR3
Flash Memory
32 MB – SPI flash
Priority Queues
8 Priority Queues per port.
Forwarding Table Age Time
Max age: 10–600 seconds.
Default = 300.
Physical and Environmental
AC Inputs
DGS-1210-10/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 0.3A
DGS-1210-10P/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 1.3A
DGS-1210-12TS/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 0.4A
DGS-1210-20/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 0.33A
DGS-1210-28/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 0.43A
DGS-1210-28P/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 3.05A
DGS-1210-28MP/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 5.48A
DGS-1210-28X/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 0.58A
DGS-1210-28XS/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 0.98A
DGS-1210-52/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 0.7A
DGS-1210-52P/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 3.36A
DGS-1210-52MP/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 5.78A
DGS-1210-52MPP/ME:
AC Input: 100 – 240 VAC, 50-60 Hz, Max. 10A
Summary of Contents for DGS-1210/ME series