- Linear drive for locking and unlocking of
standard lock-sliding fittings
- It is integrable in the fassade profile or on
the profile
- Suitable for a complete remote control of
windows and flaps, in conjunction with D+H
window drives
- Integrated electronics will control the connected
window drive
Intended use
The VLD 51/038 can be integrated in almost all
common profiles. Please consult your D+H service
and sales partner about precise mounting
specifications and CAD-data.
Attention:
Screw either tappet driver (PI-VLD) on
the VLD
51/038
before mounting of the drive.
Mounting information
Drive unit with 2,5 m (98.4") silicone cable.
Dependent on the type of window, different bracket
sets are available separately.
Scope of supply
PI-VLD
S1
S2
Factory-set
S1
S2
S1
S2
Locking direction is the direction in which
both the switches point!
Adjustment of locking/ unlocking direction
Plug connection
Clamping range :
28 -18 AWG
(solid or flexible)
< optional >
Ø max. 7 mm
(0.27")
1 2 3 4 5 6
7 8 9 10 11 12
Mot. a IN (WH)
Mot. b IN (BN)
HS IN (OG)
SG OUT
SG OUT
Signal OUT
(PK)
(YE) Mot. a OUT
(GN) Mot. b OUT
HS OUT
SG IN
SG IN
(GY) Signal / BR
V IN
(WH) white
(BN) brown
(OG) orange
(YE) yellow
(GN) green
(PK) pink
(GY) grey
Loop through terminals:
For looping through of e.g. alarm
contacts or drive- position
indicators, the floating connecting
terminals (position indicator IN,
position indicator OUT) can be
maximally loaded with
60 V / 1 A
.
Please note:
When delivered, the drive is prepared with a “BRV” status signal via
junction-box for the connection of a window drive (page 8). For other
connection variants some strands need to be cut. (page 9-10)
VLD 51/038
VLD 51/038
! IMPORTANT ! Safety Notes
1. Mounting of the drive should be carried out by a D+H distributor, whose qualification and
experience is ensured by regular in-house training.
2. All wiring must be installed by a qualified electrican according to National Electrical Codes, NFPA 70.
3. For indoor use only. Use always rain detector with danger of rain (e.g. at domelights or roof windows).
4. Observe enclosed red safety slip!
5. Danger of violent pressure in handaccessible area.
6. The window operators have been evaluated for Residential or Light Duty Commercial Use only.
7. A suitable field wiring means should be provided in the end use application.
8. The mounting and routing of external wiring should be determined in the end product.
9. The mounting of each unit shall be evaluated in the end use.
10. The suitability of the leads for field wiring should be determined in the end-use application.
11. Suitability of strain relief means in conjunction with the flexible cord shall be evaluated in the end-use,
if applicable.
12. The drive must be mounted a min of 8 feet above the floor or any access level.
13. The drives were not evaluated for entrapment protection since they are to be installed at
least 8 feet above the floor. Where entrapment is a consideration, the need for additional tests and
evaluation should be determined during the end product investigation.
14. The drive shall be connected to a Class 2 power supply.
For North America:
15. The Uniform Building Code Standard Vols. 1, 2 & 3 have to be observed.
Type
VLD 51/038
Rated voltage
24 V DC ± 20 %
Nominal current
1 A
Stroke
38 mm (1.5")
Runtime
approx. 9 s
Service life
> 10.000 double strokes
Duty cycle
30% (cycle time 10 min.)
Housing
stainless steel (V2A)
Ingress protection
IP 50
Temp. range
-5 °C...+50 °C
(23 °F... 122 °F)
Connection
2.5 m (97.5") silicone cable
Switching current drive
max. 2.5 A
Loop through contacts
60 V/ 1 A
Forces
- Locking direction
max. 500 N (112.4 lbf)
- Unlocking direction
max. 500 N (112.4 lbf)
- Breakaway force in
unlocking direction
max. 1000 N (224.8lbf)
Technical data