-  Linear drive for locking and unlocking of         
  standard lock-sliding fittings
-  It is integrable in the fassade profile or on 
  the profile
-  Suitable for a complete remote control of
  windows and flaps, in conjunction with D+H 
  window drives
-  Integrated electronics will control the connected
  window drive

Intended use

The  VLD  51/038  can  be  integrated  in  almost  all 
common profiles. Please consult your D+H service 
and  sales  partner  about  precise  mounting 
specifications and CAD-data.

Attention:

  Screw  either  tappet  driver  (PI-VLD)  on 

the VLD 

51/038 

before mounting of the drive.

Mounting information

Drive unit with 2,5 m (98.4") silicone cable. 
Dependent on the type of window, different bracket 
sets are available separately.

Scope of supply

PI-VLD

S1
S2

Factory-set

S1
S2

S1
S2

Locking direction is the direction in which
both the switches point!

Adjustment of locking/ unlocking direction

Plug connection

Clamping range :
28 -18 AWG
(solid or flexible)  

< optional >

Ø max. 7 mm

(0.27")

1 2 3 4 5 6

7 8 9 10 11 12

Mot. a IN (WH)

Mot. b IN (BN)

HS IN (OG)

SG OUT

SG OUT

Signal OUT

 (PK)

(YE) Mot. a OUT

(GN) Mot. b OUT

HS OUT

SG IN

SG IN

(GY) Signal / BR

V IN

(WH)  white
(BN)  brown
(OG)  orange
(YE)  yellow
(GN)  green
(PK)  pink
(GY)  grey

Loop through terminals:

For looping through of e.g. alarm 
contacts or drive- position 
indicators, the floating connecting 
terminals (position indicator IN, 
position indicator OUT) can be 
maximally loaded with 

60 V / 1 A

.

Please note:

When delivered, the drive is prepared with a “BRV” status signal via 
junction-box for the connection of a window drive (page 8). For other 
connection variants some strands need to be cut. (page 9-10)

VLD 51/038

VLD 51/038

! IMPORTANT ! Safety Notes

1.  Mounting  of  the  drive  should  be  carried  out  by  a  D+H  distributor,  whose  qualification  and    
experience is ensured by regular in-house training. 
2.  All wiring must be installed by a qualified electrican according to National Electrical Codes, NFPA 70.
3.  For indoor use only. Use always rain detector with danger of rain (e.g. at domelights or roof windows).
4.  Observe enclosed red safety slip!
5.   Danger of violent pressure in handaccessible area.
6.  The window operators have been evaluated for Residential or Light Duty Commercial Use only.
7.  A suitable field wiring means should be provided in the end use application.
8.  The mounting and routing of external wiring should be determined in the end product.
9.  The mounting of each unit shall be evaluated in the end use.
10.  The suitability of the leads for field wiring should be determined in the end-use application.
11.  Suitability of strain relief means in conjunction with the flexible cord shall be evaluated in the end-use,  
if applicable.
12.  The drive must be mounted a min of 8 feet above the floor or any access level.
13.  The  drives  were  not  evaluated  for  entrapment  protection  since  they  are  to  be  installed  at    
least  8  feet  above  the  floor.  Where  entrapment  is  a  consideration,  the  need  for  additional  tests  and   
evaluation should be determined during the end product investigation.
14.  The drive shall be connected to a Class 2 power supply.

For North America:
15.  The Uniform Building Code Standard Vols. 1, 2 & 3 have to be observed.

Type  

 

 

VLD 51/038

 

Rated voltage 

 

24 V DC ± 20 %

Nominal current 

 

1 A

 

Stroke 

 

 

38 mm (1.5")

Runtime 

 

 

approx. 9 s

Service life   

 

> 10.000 double strokes

Duty cycle 

 

 

30% (cycle time 10 min.)

Housing 

 

 

stainless steel (V2A)

Ingress protection    

IP 50

Temp. range  

 

-5 °C...+50 °C

   

 

 

 

(23 °F... 122 °F)

Connection   

 

2.5 m (97.5") silicone cable

Switching current drive 

max. 2.5 A

Loop through contacts 

60 V/ 1 A

 

Forces
- Locking direction   

max. 500 N  (112.4 lbf)

- Unlocking direction 

max. 500 N  (112.4 lbf)

- Breakaway force in
  unlocking direction  

max. 1000 N (224.8lbf)

Technical data

Summary of Contents for VLD 51/038

Page 1: ...9 824 36 2 1 10 15 PI VLD Please order bracket sets separately Rogamos que pidan los juegos de fijaci n por separado E 222052 C US en Original instructions Page 2 es Manual original P gina 5 VLD 51 03...

Page 2: ...tial or Light Duty Commercial Use only 7 Asuitable field wiring means should be provided in the end use application 8 The mounting and routing of external wiring should be determined in the end produc...

Page 3: ...YE Mot a OUT GN Mot b OUT HS OUT SG IN SG IN GY Signal BRV IN WH white BN brown OG orange YE yellow GN green PK pink GY grey Loop through terminals For looping through of e g alarm contacts or drive p...

Page 4: ...sole responsibility that the product described under Technical Data is in conformity with the following directives 2014 30 EU 2014 35 EU Technical file at D H MechatronicAG D 22949Ammersbek Thomas Ke...

Page 5: ...nenlas reasaccesiblesconlasmanos 6 Los operadores de las ventanas han sido evaluados nicamente para su uso residencial o para el uso comercial simple 7 Se deber n suministrar dispositivos apropiados...

Page 6: ...N SG IN GY Signal BRV IN Bornes de enlazado Para enlazar p ej contactos de alarma o indicadores de posici n del actuador los bornes de conexi n libres de potencial SG y HS pueden cargarse con un m xim...

Page 7: ...el producto descrito bajo Datos t cnicos est en conformidad con las regulaciones 2014 30 EU 2014 35 EU Expediente t cnico en D H MechatronicAG D 22949Ammersbek Thomas Kern Maik Schmees Junta directiv...

Page 8: ...a Mot b HS BRV Connection Conexi n 1 2 3 4 5 6 7 8 9 10 11 12 VLD 51 038 7 1 8 2 9 3 10 4 11 5 12 6 WH BN OG PK YE GN GY HS SG1 SG2 BRV Signal OUT Mot a OUT Mot a IN Mot b OUT Mot b IN Protect agains...

Page 9: ...8 7 1 8 2 9 3 10 4 11 5 12 6 WH BN OG Mot a Mot b HS HS SG1 BRV SG2 BRV Signal OUT EM 47 K 1 2 3 4 5 6 7 8 9 10 11 12 Mot a OUT Mot a IN Mot b OUT Mot b IN Drive Motor WLC GN YE PK GY Junction box Caj...

Page 10: ...Mot b OUT Mot b IN Mot b HS HS SG1 SG2 Signal IN Signal OUT EM 47 K 1 2 3 4 5 6 7 8 9 10 11 12 GN YE Junction box Caja de conexi n Monitoring Supervisi n not in case of no en el caso GVL 8xxx E K M D...

Page 11: ...Espa ol VLD 51 038 26 25 1 2 25 within range of coiled spring pins En el sector de los manguitos de sujeci n Dimensions Dimensiones 5 5 x 10 5 5 359 stroke 4 4 9 4 7 5 397 4 9 3 All sizes in millimetr...

Page 12: ...many 22949Ammersbek 49 239 Tel 40 605 65 49 Fax 40 605 65 254 E Mail info dh partner com www dh partner com 2014 D H Mechatronic AG Ammersbek Rights to technical modifications reserved Derecho reserva...

Reviews: