Mounting of drive:
Because  of  varied  possiblilties  for  choosing  drives, 
Please  take  mounting  informations  from  relevant 
instructions for use of the respective drive.

Moving direction of drives:
Change poles of wires of the drive supply   („Mot.a" 
and „Mot.b"), when  moving direction is wrong.

Window drives (Accessories)

Connection – Rain sensor and Room temperature control

optional

 >

rain

Wind

Wind

+

1

2

4

3

5

7

6

8

9

R

W

WRG 82

S 1/1

S 1/2

P3

P4

+G

Zz

Az

1

2

3

4

GVL 8408-M

L

N–

Z

A

X

Mot.a

Mot.b

1

2

3

4

5

6

7

GVL 8408-M

LT

MOT

LT 84-U +

LT 84-U-W

close

–N

open

P

P

S

VRS 10

rain

+24V

2

1

3

4

5

6

R

insert bridge!

insert bridge!

*  Connect lead directly when no automatic switch available. 
 

In this case the manual operation is out of function.

Mot.a

Mot.b

Mot.a

Mot.b

Line lengths and 
cross sections 
see page 4

branch box

branch box

Only if wind detector or rain detector available:

If the weather automatic is switched on via vent button LT 84-U-W 
(optional), the system will automatically close in case of wind or rain.
The system will not automatically open again, if wind or rain has stopped. 
Opening of the system for ventilation via vent button.
The weather automatic can be switched-off at vent button LT 84-U-W 
(optional), if gap ventilation is required in case of bad weather.
Gap ventilation is not possible in case of bad weather, if no vent button
LT 84-U-W available.

Operation - Weather automatic

The input current of the
connected window drives
shall not exceed 4 Amp.

WARNING

ST OP

ST OP

ST OP

Operation - Day-to-day ventilation

Open:

Close:

Stop:

Ventilation button required.

ST

OP

Automatic

on/off

LT 84-U-W

Electrical devices, accessories, batteries and packa-
ging  should  be  sorted  for  environmental-friendly 
recycling.  Do  not  dispose  electrical  devices  and 
batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for 
waste  electrical  and  electronic  equipment  and  its 
implementation into national right, electrcal devices 
that are no longer usable must be collected separa-
tely  and  disposed  of  in  an  environmentally  correct 
manner.

Disposal

Maintenance and cleaning

Inspection  and  maintenance  has  to  be  carried  out 
according  to  D+H  maintenance  notes.  Only  original 
D+H spare parts may be used. Repair is to be carried 
out exclusively by D+H.
Wipe away debris or contamination with a dry, soft 
cloth.
Do not use cleaning agents or solvents.

Summary of Contents for GVL 8408-M

Page 1: ...GVL 8408 M en Original instructions Page 2 99 824 66 1 6 03 16...

Page 2: ...recautions should always be followed to reduce risk of fire electric shock and personal injury Failure to follow these instructions could result in death or serious injury Operating voltage 115 VAC Co...

Page 3: ...tion key operation OPEN CLOSE can be free encoded Weather automatic for single groups can be switched on and off Entry for external control e g timer Possibility of connecting rain detector or wind ra...

Page 4: ...S1 S5 on motherboard of control panel and on group plug in unit if available The delivery state of all DIP switches is OFF 1 ON Drives CLOSE up to final position by single pressing on respective vent...

Page 5: ...al only LT 84 U SD LT MOT 1 2 3 Vent button e g LT 84 U SD L P Mot b Mot a 24 V DC Window Drives Mot b Mot a 4 GVL 8408 M G Az Zz X1 1 2 3 External contact for central closing e g rain detector Drive...

Page 6: ...ot b 1 2 3 4 5 6 7 GVL 8408 M LT MOT LT 84 U LT 84 U W close N open P P S VRS 10 rain 24V 2 1 3 4 5 6 R insert bridge insert bridge Connect lead directly when no automatic switch available In this cas...

Page 7: ...ation is not possible in case of bad weather if no vent button LT 84 U W available Operation Weather automatic ST OP ST OP ST OP Operation Day to day ventilation Open Close Stop Ventilation button req...

Page 8: ...Germany 22949Ammersbek 49 239 Tel 40 605 65 49 Fax 40 605 65 254 E Mail info dh partner com www dh partner com 2012 D H Mechatronic AG Ammersbek Technische nderungen vorbehalten Rights to technical mo...

Reviews: