CDP-TW-K-BSY+

99.830.99 1.2/11/15

7/24

English

CDP-TW-K-BSY+

Main closing edge

Beside closing edge

Beside closing edge

In the "CLOSE" direction the drive has an active protection 
for the main closing edge. If there is an overload in the closing 
range 3 and 2, the drive runs "OPEN" for 10 seconds, then 
"CLOSE" again. If after three attempts closing is not possible, 
the drive remains in this position.
In addition, the drive is equipped with passive protection. The 
closing speed in closing range 2 and 1 is reduced to 5 mm/s.

There are still substantial forces that
pose a risk to life and limb.
Significantly greater forces can be
exerted at the secondary closing
edges. Danger of crushing hands and
fingers!

Closing edge protection

Performance features

- Micro processor controlled  synchro electronics

BSY + for a precise     synchronous run of  up to
2 drives

- Individually programmable (via software SCS)
- SHEV-high speed function (fast-running

feature in OPEN-direction)

- Protection system for the main closing edge
- Locking relief after closing
- Especially quiet motor running in ventilation mode
- Symmetrical chain outlet
- Connection via pin-and-socket connector
- Optinal with "-AS2" = protection class 2 and

"-AS3" as well as "-LS" = protection class 3

Intended use

- Chain drive for electric opening and closing of heavy

windows and flaps in the facade and roof area

- Operating voltage 230 V AC
- Useable for smoke ventilation, D+H Euro-SHEV

according to DIN EN 12101-2 as well as
daily natural ventilation

- Only for inside mounting

Technical data

Observe maximum pressure load of the chain!
Maximum  pressure  load 

per  chain

  is  not 

automatically identical with maximum pressure force 
of the drive!

Pressure load diagram

250

500

750

1000

1250

1500

1750

2000

1500

1000

500

0

max. 

Load

 (N)

Stroke  (mm)

3000

2500

per chain

total

Operating voltage 230 V AC!
Risk of injury from electric shock!
Do not reverse L+N! Connect PE!
The BSY+ bus also operates with 230V!

- Connection has to be carried out only by an

authorized electrical specialist

- Danger of violent pressure in handaccessible area
- Keep away People from the operating area of the

drive

- Keep away children from the control
- Observe pressure load diagram of the chain!
- Use only in dry rooms
- Only for inside mounting.

Use rain detector with danger of rain
(e.g. at domelights or roof windows)

- Just use unchanged original D+H parts
- Observe mounting instructions of bracket set!

Observe enclosed r

  

ed safety slip!

Safety notes

Drive unit with 2,5 m silicone cable. Dependent on 
the  type  of  window,  different  bracket  sets  are 
available separately.

Extent of supply

OPEN

Forces

CR 

III

CR 

II

CR 

I

2 x 800 N
2 x 800 N
2 x 800 N
2 x 500 N

CDP-TW 1600

C

L

O

S

E

2 x 1500 N
2 x 1000 N
2 x 1000 N

2 x 500 N

CDP-TW 3000

2 x 1000 N
2 x 1000 N
2 x 1000 N

2 x 500 N

CDP-TW 2000

Running speed and forces 

Normal  operation

  =

SHEV- fast running =

All forces
+ approx. 20 % switch-off reserve (temporary)

Closure Ranges

Type 

CDP-TW 1600-K-BSY+  CDP-TW 2000-K-BSY+  CDP-TW 3000-K-BSY+

Power supply 

230 V AC, +10 % / -15 %, 50 Hz

Power consumption 

100 W / 142 VA 

120 W / 160 VA 

160 W / 214 VA

Nominal force 

2 x 800 N 

2 x 1000 N 

2 x 1500 N

Nominal locking force 

2 x 1500 N

Lifetime *** 

>10 000 double strokes

Reliability 

Re = 400

Duty cycle 

30 % S2 (EN 60034-1), no continuous voltage

Housing 

Aluminium, PC/ABS (end covers)

Ingress protection 

IP 32

Temperature range 

-5 ... +75 °C

Fire stability 

30 min / 300 °C

Nominal stroke length *;**  See type plate
Additional functions * 

Closing edge protection activated (3 stroke repeatings),
locking relief activated (0,3 mm)

*   Programmable with software SCS
**  1000 mm max. according to VdS 2580
***  (500 mm) according to VdS 2580

WARNING

Read all safety warnings, instructions, illustrations 
and specifications provided with this product.
Failure to follow all instructions listed below may 
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future 
reference.

Summary of Contents for Dyer CDP-TW-K-BSY+ Series

Page 1: ...Please order bracket sets separately CDP TW K BSY instructions...

Page 2: ...0 500 750 1000 1250 1500 1750 2000 1500 1000 500 0 max Load N Stroke mm 3000 2500 per chain total Operating voltage 230 VAC Risk of injury from electric shock Do not reverse L N Connect PE The BSY bus...

Page 3: ...500 N CDP TW 1600 CLOSE 2 x 1500 N 2 x 1000 N 2 x 1000 N 2 x 500 N CDP TW 3000 2 x 1000 N 2 x 1000 N 2 x 1000 N 2 x 500 N CDP TW 2000 Running speed and forces Normal operation SHEV fast running All fo...

Page 4: ...n Danger Operating voltage 230 V AC Risk of injury from electric shock Do not reverse L N Connect PE The BSY bus also operates with 230V Strain on glass can cause the glass to break Cordon off the dan...

Page 5: ...electrcal devices that are no longer usable must be collected separa tely and disposed of in an environmentally correct manner Disposal Declaration of Conformity We declare under our sole responsibil...

Page 6: ...CDP TW K BSY 80 mm 35 mm Cable mounting 5 4 6 3 2 1 8 7 Cable dismounting inverse order Connection PE...

Page 7: ...K Lr OG n c BN Ls BN Ls PinAssignment Standard Option SGI BU N BU N GN Data B GN Data B GN n c YE Data A YE Data A GY n c YE GN YE GN WH n c BN n c GN green YE yellow BU blue BN brown BK black WH whit...

Page 8: ...BK Lr OG n c OG n c BN Ls BN Ls PK SA PK SA PinAssignment Option SA SZ Option SGI SA SZ BU N BU N YE SA YE SA GN Data B GN Data B GN SZ GN SZ YE Data A YE Data A GY SZ GY SZ YE GN YE GN WH n c WH n c...

Page 9: ...SCS 30 006 23 BI BT 2 2x Size AA LR6 1 5V Co nn ect ed Po we r BI BT 2 Bus Interface D H Mec hatr onic AG www dh part ner com 49 0 4 0605 65 0 Se rvic etim er Sta tus Cre dits Re set Re set 10 Cre dit...

Page 10: ...mm 2002 mm 401 mm 401 mm 401 mm 401 mm 401 mm 401 mm 401 mm 800 mm 1000 mm 1200 mm 1500 mm 600 mm 800 mm 1000 mm 1200 mm 1500 mm B A Weight 16 6 kg 17 7 kg 19 7 kg 21 4 kg 14 9 kg 16 4 kg 17 7 kg 19...

Page 11: ...Dyer Environmental Controls Ltd Unit 10 Lawnhurst Trading Estate Cheadle Heath Stockport SK3 0SD Tel 44 0 161 491 4840 E Mail enquiry dyerenvironmental co uk www dyerenvironmental co uk...

Reviews: