When calibrating the pump, it is best to use a head speed setting that is appropriate to the flow rate 
you will be operating. For example, if you are planning to set the pump at a flow rate of 60ml/min 
then use a rotation speed of 150rpm. If the pump has already been set to the desired flow rate this 
will automatically display a suitable head speed for calibration. 

If the speed needs adjusting for calibration tap on ‘Rotation’ and enter the speed setting. 

Make sure the inlet hose for the pump is submerged and that the outlet hose is directed into a 
suitable collection container.  

Tap on ‘Start Priming’ to prime the pump head and hose. Once all air has been expelled and the line is 
fully primed tap ‘Emptying, click to stop’. 

Move the outlet hose into a suitable measuring cylinder.  

Set the time for pump calibration by selecting ‘Add time’ and scrolling through to the desired time. 
This can be set up to 60 seconds. For increased accuracy, a longer calibration time is best. Please be 
aware the measuring cylinder needs to be large enough to hold the volume of the water for the 
calibration.  

Tap on ‘Start Add’ and the pump will run for the time selected in the previous step. 

Once the pump has stopped remove the outlet hose from the measuring cylinder and stand the 
measuring cylinder on a flat level surface. Use the scale on the side to determine the volume of liquid.  

Enter the volume of liquid collected in ml by tapping in the space next to “Enter volume”.  

Select calibration complete at the bottom of the page and the pump will calculate the flow rate from 
the time and volume you have entered. The pump is now calibrated. 

 

Manual calibration using the control dial 

If the pump is not being controlled via the app calibration can be done using the LCD display and 
control dial on the unit. 

If the pump is running press the control dial to stop it running.

 

 

Turn the control dial to enter the menu on the pump. Scroll the dial until ‘Cal’ is highlighted then 
press the control dial. 

w

w

w

.th

ea

qu

ari

um

slu

tio

n.c

om

 

Summary of Contents for Kamoer FX-STP WIFI

Page 1: ...FX STP WIFI PERSTALTIC PUMP USER MANUAL...

Page 2: ...your pump to the app 5 Programming the pump in the app 6 Manual app override 7 Manual pump operation 7 Calibration Using the app 7 Manual calibration 8 Advanced Settings Settings in the app Renaming...

Page 3: ...fers long life heat resistance acid alkali resistance and ozone UV resistance Min flow rate 0 1ml minute Max flow rate 140ml minute Easily calibrated via the Kamoer Remote app or manual control dial T...

Page 4: ...orrect on the pump head and that the hoses are pushed fully onto connections before installation The pump head adjustment screw should never be over tightened this will cause excessive wear on moving...

Page 5: ...Play store search for Kamoer Remote and download the app with the corresponding icon above Kamoer Remote app supports Android 4 4 and above and supports iOS 9 1 and above Register your cloud account Y...

Page 6: ...o two separate 2 4 and 5ghz networks before attempting to connect the pump Connect the power supply to the DC socket on the back of the pump and plug in to a mains power source Open the App click the...

Page 7: ...e flow rate of the pump can be set by tapping on the flow setting number and entering the desired flow rate or by moving your finger along the flow curve above the number When the desired flow rate ha...

Page 8: ...screen and then re select the device Manual pump operation The FX STP Wi Fi does not need to be connected to the app for basic operation To set the flow rate of the pump press the control dial to set...

Page 9: ...t up to 60 seconds For increased accuracy a longer calibration time is best Please be aware the measuring cylinder needs to be large enough to hold the volume of the water for the calibration Tap on S...

Page 10: ...Turn the control dial to select 60s then press The pump will run for 60 seconds as it does the time will countdown on the LCD screen When finished place the measuring cylinder on a flat level surface...

Page 11: ...he maximum life can be achieved and that the head runs smoothly Calibrate the pump Used to calibrate the unit to ensure correct flow rate Please see calibration in this instruction manual Reset progra...

Page 12: ...displayed in the top right corner of the LCD screen built into the pump NET 0 Indicates that the network is connected and functioning NET S The pump is in distribution state and is ready to be connec...

Page 13: ...of the date of purchase D D The Aquarium Solution Ltd undertakes to repair or at our decision replace the defective part free of charge Our policy is one of continual technical improvement and we rese...

Reviews: