2.4 Equalization
2.5 Low mains voltage
If mains voltage falls below the shutdown
voltage for the unit, it will stop playing. When
acceptable levels are regained, the unit will switch
back on automatically.
Stage Monitor Series units have been thought
of to be used as full range systems not requiring any
additional signal processing. Being SML a versatile
multipurpose cabinets they can be used in
combination with subwoofer units such as Sub-18A.
It is recommended to plug the mixer into the Sub18A's
input and then to connect the Sub18A high pass
filtered output (SATELLITE OUTPUT) to the SML's
input. That way the signal being fed into the SML will
be high pass filtered at 100 Hz (dotted graph in the
picture).
2.6 Connections
The units do not need extreme settings of
equalisation to produce quality sound. Avoid high
levels of gain on the equalisers. Gain values above +6
dB on a console's EQ are not recommended.
Power Link: Max 4 units
SML-12A
LINE
SIGNAL
INPUT
SATELLITE
OUTPUT
100 Hz
All of the models in the Stage Monitor Series
feature signal output connectors (XLR) and current
output connectors (PowerCon) in order to allow
linking both signal and mains power. Due to the
PowerCon current limit, only a maximum of 4 units
can be linked together.
2.7 Side changing of the amplifier
Firstly unscrew the metal plate and the
amplifier (20 M4x20 DIN 7985). Then unplug the
white speaker connector and finally swap places.
SML-12A is provided with the high frequency
driver on the right side. When used as a floor monitor,
and when the high frequency driver is needed on the
left side, the amplifier must swap places with the
metal plate attached to the other flat side of the box.
Stage Monitors
Manual del usuario/
User´s manual
14