CONFIGURATIONS (cont’d)

8  x  EVENT-26A  + 4

    x  EVENT-115A 

Units

Processors 

Rigging frames 

2

AX-EV26

 

Rigging bumper for EVENT-26A / EVENT-115A

Dollies

PL-EV115S

 

Plywood transport dolly for EVENT-115A  

2

PL-EV26S 

Steel transport dolly for EVENT-26A

2

Speaker cabling

SC-1

 

1m XLR microphone signal balanced cable

SC-20

 

20m XLR microphone signal balanced cable

4

2

PWCONLINK-09 

0.9m powerCON  “jumper” NAC3FCB cable

8

SC-05

 

0.5m XLR microphone signal balanced cable

6

AX-EV26

MAIN MENU

BACK

PRESET: loud

LPF: Top

MAIN MENU

BACK

DownFill: off

No.of U: 

<4U>

Summary of Contents for EVENT SERIES

Page 1: ...zar el equipo lea la sección Precauciones de seguridad de este manual Conserve este manual para futuras consultas Before operating the device please read the Safety precautions section of this manual Retain this manual for future reference line array ...

Page 2: ...scriptions ON OFF Overload indicator Overheating Equalisation Low mains voltage Current consumption CONFIGURATIONS 4 or 6 units mounting on a PL EV26S flatbed dolly SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY Manual del Usuario event series User s Manual Troubleshooting Array mounting of groups of 4 units on a flatbed dolly EVENT 115A array mounting EVENT 26A array mounting one by one EV...

Page 3: ...e debe entregarse en el correspondiente punto de recogida de equipos eléctricos y electrónicos This symbol on the product indicates that this product should not be treated as household waste Instead it shall be handed over to the appicable collection point for the recycling of electrical and electronic equipment El cableado exterior conectado al equipo requiere de su instalación por una persona in...

Page 4: ...viamente manipulado e incluir una fotocopia de la factura de compra Todos los detalles relativos a la garantía como las garantías extendidas los puede encontrar en la sección SOPORTE en nuestra web www dasaudio com All our products are warrantied against any manufacturing defect for a period of 24 months from date of purchase The warranty excludes damage from incorrect use of the product All warra...

Page 5: ...magnetic compatibility of multimedia equipment Emission requirements l EN 55103 2 2009 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 2 Immunity l EN 50581 2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substa...

Page 6: ...installation applications The EVENT 26A combines two 6 5 transducers and a single M 60 compression driver in a rugged yet lightweight polymer cabinet The symmetric V shaped configuration of the cone transducers provides consistent 100º of horizontal coverage down to 200 Hz The M 60 compression driver is coupled to an advanced waveguide design that provides control of the vertical dispersion as wel...

Page 7: ... for high efficiency and long excursion offering a power handling capacity of 1200 Wprogram Efficient cooling is assured thanks to the 15FW4 s vented pole piece and abundant apertures in the speaker s back plate keeping power compression to a minimum while providing high acoustic output over extended periods Driving the DAS 15FW4 loudspeaker is a cutting edge 1200 Wpeak Class D amplifier On the re...

Page 8: ...ZT Speaker adaptor for pole mount Dollies PL EV115S Plywood transport dolly for EVENT 115A 1 PL EV26S Steel transport dolly for EVENT 26A 1 Speaker cabling SC2 2m XLR microphone signal balanced cable SC20 20m XLR microphone signal balanced cable 2 2 2 x EVENT 26A 2 x EVENT 115A AXS EV26 TRD 7 AXC ZT MAIN MENU BACK PRESET loud LPF Top MAIN MENU BACK No of U 1U DownFill off ...

Page 9: ...PL EV115S Plywood transport dolly for EVENT 115A 2 PL EV26S Steel transport dolly for EVENT 26A 2 Speaker cabling SC 1 1m XLR microphone signal balanced cable SC 20 20m XLR microphone signal balanced cable 4 2 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 8 SC 05 0 5m XLR microphone signal balanced cable 6 AX EV26 MAIN MENU BACK PRESET loud LPF Top MAIN MENU BACK DownFill off No of U 4U ...

Page 10: ...dolly for EVENT 115A 2 PL EV26S Steel transport dolly for EVENT 26A 2 Speaker cabling SC 1 1m XLR microphone signal balanced cable SC 5 5m XLR microphone signal balanced cable SC 05 0 5m XLR microphone signal balanced cable 2 2 6 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 8 SC 20 20m XLR microphone signal balanced cable 2 AX EV26 PL EV115S MAIN MENU BACK DownFill off No of U 4U MAIN MENU BACK...

Page 11: ...nal processor 2 10 1 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 12 SC 20 20m XLR microphone signal balanced cable 2 AX EV26A MAIN MENU BACK PRESET loud LPF Top MAIN MENU BACK DownFill off No of U 6U www dasaudio com CAUTION DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE RISK OF ELECTRIC SHOCK DO NOT OPEN OUTPUT A OUTPUT B HPF THRU SATELLITE X OVER LIMIT SIGNAL ON POLARITY LEVEL 6 oo 0 LOW P...

Page 12: ...or 2 10 1 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 12 SC 20 20m XLR microphone signal balanced cable 4 12 x EVENT 26A 4 x EVENT 218A MAIN MENU BACK DownFill off No of U 6U www dasaudio com CAUTION DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE RISK OF ELECTRIC SHOCK DO NOT OPEN OUTPUT A OUTPUT B HPF THRU SATELLITE X OVER LIMIT SIGNAL ON POLARITY LEVEL 6 oo 0 LOW PASS 100Hz 63Hz 80Hz INPUT...

Page 13: ...I 6MI HF 1 x M 60 GM M60N LF 1 x 15FW4 GM 15FW4 Enclosure Geometry Trapezoidal 5º Rectangular Enclosure Material ABS High Impact Birch Plywood Color Finish Black Polyurea Paint Black Polyurea Paint Rigging System Splay Angles Integrated in box design Integrated in box design Connectors INPUT 1 x Female XLR LOOP THRU 1 x Male XLR AC INPUT 1 x powerCON NAC3FCA AC OUTPUT 1 x powerCON NAC3FCB INPUT 2 ...

Page 14: ...14 Manual del Usuario event series User s Manual LINE DRAWINGS EVENT 115A EVENT 26A ...

Page 15: ...ckground light of the display can be switched off permanently by selecting in the options Dimming menu the dark preset This option will make the Display blink on and off when the system reaches its limit This option maybe useful in theaters or similar applications in order to reduce the visual contamination 4 ENCODER DAScontrol Use the rotary encoder to navigate for preset selection number of unit...

Page 16: ...o the Limiter threshold can be monitored on the right meter When the value reaches the limiter threshold the Display will show LIMIT depending on the configuration mode the Display can be programmed to blink when the system is limiting SIGNAL The left meter indicates the presence of signal ON The Display will be illuminated when the system is on The background light of the display can be switched ...

Page 17: ...m Delay 0 0m OPTIONS OPTIONS MENU OPTIONS MENU BACK BACK CONTRAST 0 BRIGHT 10 BRIGHT 10 CONTRAST 0 OPTIONS MENU OPTIONS MENU OPTIONS MENU MENU LOCK off DLY UNITS m DLY UNITS m DIMMING on DIMMING on DIMMING on MENU LOCK off MENU LOCK off OPTIONS MENU RESET DEVICE INFORMATION Are you sure BACK YES DLY UNITS m off the background light is always on on the background light is lowered when the system doe...

Page 18: ... DLY UNITS m DLY UNITS m DIMMING on DIMMING on DIMMING on MENU LOCK off MENU LOCK off OPTIONS MENU RESET DEVICE INFORMATION Are you sure BACK YES DLY UNITS m off the background light is always on on the background light is lowered when the system doesn t Limit when Limit is reached the background light increases its luminosity dark the bakcground light is always off RESET DEVICE NO OPTIONS MENU BACK...

Page 19: ...urs the FAN EVENT 26A will automatically start working reducing the temperature of the unit Make sure that the rain protectors are properly separated from the amplifier s back plate in order to not block the air flux thru the fan Equalisation It is recommended the use of a computer based dual channel FFT platform to view the frequency content of signals or measure the response of the entire electr...

Page 20: ...ree phase AC the lighting equipment and the UNIT are connected to the same phase 1 Bad or loose AC connection to the UNIT or the mains outlet 2 FaultyAC cable 3 Blown Fuse 4 The mains voltage is out of range SOLUTION 1 Check all the connections and the power distro 2 Check that the cable and connector are working properly 3 Contact with the dealer tech support in the area 1 If you use a mixer be s...

Page 21: ... elements For slings and elements exposed to material fatigue due to friction and load variation the following ratios must be met 5 1 for steel clable slings 4 1 for steel chain slings and 7 1 for polyester slings Thus an element with a breaking load limit of 1000 kg may be statically loaded with 200 kg 5 1 safety factor and dynamically loaded with 142 kg 7 1 safety factor When a system is flying ...

Page 22: ...he pin in hole 1º at Rear Link in the first EVENT 26A 4 or 6 units mounting on a PL EV26S flatbed dolly Use 3 pins PIN 6 of the PL EV26S 2 at the front one on each side Rear Link at 1º Fig 1 2 4 6 0 1 3 5 7 9 10 8 10 1 PIN HOLDER Use 4 pins PIN 6 of the bottom EVENT 26A 2 at the front and 2 at the rear link Fig 2 The next figure shows the detail of the label located at the rear rigging structure of...

Page 23: ...s is shown 4 or 6 units mounting on a PL EV26S flatbed dolly Fig 6 Fig 5 At his point the cover for 4 units could be placed to protect them during transportation Finally the rigging bumper AX EV26 can be attached to the top cabinet using its available pins insert two pins at the front and one at the rear keep the extra pin stored in the cabinet Fig 7 set splay ...

Page 24: ...3 pins are needed Next step would be running an Ease Focus simulation in order to know the different splay angles between the units and the pick up position pin point of the central bar Before attaching the chain hoist to the AX EV26 the user should be able to vary the splay angles between units and modify them accordingly to the Ease Focus 3 simulation Warning Verify the correct installation of t...

Page 25: ...it In the sample shown only three pins per cabinet are used set splay angles lower the 4 units Fig 10 Fig 11 NOTE To rig the system the simplest approach is using three pins two at the front and one at the rear With this method the splay angle between units is set automatically while the cabinets are lifted up If the user needs to lock the splay angle between the units an extra pin pin number 4 ha...

Page 26: ...26 Manual del Usuario event series User s Manual EVENT 115A Array mounting Fig 12 Fig 13 Fig 14 Fig 15 ...

Page 27: ...27 Manual del Usuario event series User s Manual EVENT 26A Array mounting one by one Fig 16 Fig 17 Fig 18 Fig 19 set splay set splay set splay ...

Page 28: ...unting Fig 20 JP EV26 First step will be assembling the subwoofers with the AX EV26 follow the process shown on previous pages Next step before hanging the EVENT 26A units is to fix to the bottom EVENT 115A the joining plate JP EV26 Fig 21 Fig 22 Two pins Fig 24 Fig 23 set splay ...

Page 29: ...ENT 115A Fig 25 Angle between first EVENT 26A and EVENT 115A Cam link Hole real splay angle 9º 4º 8º 4º 7º 2º 6º 2º 5º 0º 4º 0º 3º 2º 2º 2º 1º 3º 0º 3º JP EV26 joining plate is needed to stack the systems Fig 26 Fig 27 set splay angle Fig 28 Fig 29 in this case splay angle 3º ...

Page 30: ...XS EV26 When using the AXS EV26 to stack the system on a tripod TRD 2 or TRD 7 pole mount and AXC ZT accessoty is also needed Fig 30 AXS EV26 AXC ZT TRD 2 Fig 31 First fix the AXC ZT to the AXS EV26 After first step fix the EVENT 26A to the AXS EV26 Fig 32 Rear View Detail ...

Page 31: ... 99 event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 218A event 218A event 218A event 218A event 218A event 218A event 218A event 218A event 121A event 121A event 121A event 121A ...

Page 32: ...ed by the shield affects both signal conductors in the same way At the device s input the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use balanced inputs and outputs Connectors that can carry balanced signal have three pins such as XLR Cannon and 6 35mm stereo The graphs that follow show the re...

Page 33: ...UM_EV3_01_EN www dasaudio com DAS Audio Group S L C Islas Baleares 24 46988 Fuente del Jarro Paterna Valencia España Tel 34 96 134 0860 ...