background image

10

EN

PROBLEM

No

sound

from

the

unit.

The

SIGNAL LED does not light up.

Full power cannot be obtained. The
LIMIT LED never lights up.

Sound is distorted. The LIMIT LED is
not on, or only lights up occasionally.

Sound is distorted and very loud
and LIMIT LED lights up.

Hum or buzz when a mixer is
connected to the unit.

Hum or buzz when using lighting
controls in the same building.

The ON LED does not light up when
the mains connector is connected
and the unit is switched to ON.

CAUSE

1 – The signal source is sending no
signal.
2 – Defective cable.

3 - The amplifier has overheated.

The signal source does not have a
hot enough output.

The

mixer

or

signal

source

is

distorting.

The system is overloaded and has
reached maximum power.

1.– The console probably has un-
balanced outputs. You may be using
an

incorrect

un-balanced

to

balanced cable.
2.– The mixer and the powered
speaker are not plugged into the
same mains outlet.
3.– The audio signal cable is too
long or too close to an AC cable

1.– The audio signal cable is too
long or too close to the lighting
cable.

2.– On a sound system with three-
phase AC, the lighting equipment
and the UNIT are connected to the
same phase.
1.– Bad or loose AC connection to
the UNIT or the mains outlet.
2 – Faulty AC cable.

3 – Blown Fuse.

4 - The mains voltage is out of
range.

SOLUTION

1 – Check that the mixer or sound
source is sending signal to the UNIT.
2 – Check that the cable from the
sound

source

to

the

UNIT

is

connected correctly. Replace the
cable if defective.
3 - Allow the unit to cool down for
some minutes and it will function
again. Check the main output level
of the mixer or channel gains since
the unit will have been functioning
with excessive levels.

If using a mixer, use the balanced
output

if

available.

Use

a

professional mixer with a hotter
output.

Turn mixer channel gains down.
Check that none of your signal
sources are distorting.

Turn down the mixer's output.

1.–

Read

the

appendix

of

this

manual

to

make

a

correct

un-

balanced to balanced cable.

2.– Connect the mixer and the unit
to the same mains outlet.

3.– Use a cable that is as short as
possible and/or move the audio
signal

cable

away

from

mains

cables.
1.– Move the audio signal cable
away from lighting cables. Try to find
out at what point the noise is leaking
into the system.
2.– Connect the sound system to a
different phase than the lights. You
may need the help of an electrician.

1.– Check your connections.

2.– Check the cables, connectors
and AC power with a suitable mains
tester.
3.- Replace the blown fuse for
another of the same type and size.
4.- If the multimeter determines that
the mains voltage is out the range,
you may need the assistance of an
electrician to find an appropriate
solution.

TROUBLESHOOTING

Manual del Usuario

/

serie avant

/

User’s Manual

Summary of Contents for Avant 12A

Page 1: ...utilizar el equipo lea la secci n Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions section of this manual...

Page 2: ...avant...

Page 3: ...re 15 C y 42 C con una humedad relativa m xima del 95 con un rango de 10 de la tensi n nominal de alimentaci n indicada en la etiqueta trasera seg n IEC 60065 2001 Working temperature ranges from 15 C...

Page 4: ...a es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra GARANT A All D A S products are warrantied against any manufacturing defect for...

Page 5: ...002 95 CE Directiva RAEE WEEE 2002 96 CE Y es conforme a las siguientes Normas Armonizadas Europeas In accordance with Harmonized European Norms l l l EN 60065 2002 Audio video and similar electronic...

Page 6: ...Manual del Usuario serie avant User s Manual...

Page 7: ...SPECIFICATIONS APPENDIX 13 General information Preliminary ON OFF Overload indicators Overheating Equalisation Low mains voltage Line connections unbalanced and balanced 6 RIGGING 7 8 10 11 11 12 ava...

Page 8: ...EN Manual del Usuario serie avant User s Manual...

Page 9: ...N other blue LED indicates ON at the unit front LEVEL Potentiometer for adjusting the unit level MONITOR MAIN Knob for switching between two types of frequency response see graphs Press the knob to us...

Page 10: ...ctor just like the LOOP THRU connector with the following pin assignments MIC LINE Knob for switching between microphone and line sensitivities FUSE Fuse holder Use only the recommended fuse type and...

Page 11: ...SIGNAL Green LED indicates signal presence ON Blue LED indicates that the unit is ON SUB LEVEL Potentiometer for adjusting the unit level 1 2 3 4 5 6 avant 18A amplifier WARNING TO REDUCE RISK OF FIRE...

Page 12: ...are regained the unit will switch back on automatically Overheating This equipment does not normally overheat during normal conditions of use When overheating occurs the unit protects itself You shou...

Page 13: ...of the enclosure to free a rigging point Fix a M10 eyebolt in each point Note that each rigging point has 200 kg 440 lb working load limit Then choose the slings or chains of required load resistance...

Page 14: ...is ideal for applications such as presentations A V etc avant avant 12A 18A Configuration 2 or two subwoofers and two avant avant avant avant 12A 15A 18A 12A Basic configuration with two used as stag...

Page 15: ...in live events Dj s etc avant avant 215A 18A Configuration 4 Typical configuration using systems for live events avant Note The units should be paralleled using the SATELLITE OUTPUT in the THRU posit...

Page 16: ...ge is out of range SOLUTION 1 Check that the mixer or sound source is sending signal to the UNIT 2 Check that the cable from the sound source to the UNIT is connected correctly Replace the cable if de...

Page 17: ...215A ALL DIMENSIONS IN MILIMETERS 540 650 630 avant avant avant 12A 15A 215A avant 18A DSP LINEAR PROCESSING LOW LOW MAIN MAIN OUTPUT B OUTPUT A LF LF x2 for avant 215A HF HIGH Switching Power Supply...

Page 18: ...8 dBu Mic 20 mV 32dBu Line 1 95V 8dBu Frequency Range 10 dB 60 Hz 20 kHz EQ main 45 Hz 20 kHz EQ flat 40 Hz 20 kHz EQ flat 35 Hz 160 Hz variable X over 3 Maximum Peak SPL at 1 m 133 dB 133 dB 136 dB...

Page 19: ...the same way At the device s input the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use balance...

Page 20: ...14 EN Manual del Usuario serie avant User s Manual...

Page 21: ......

Page 22: ...DAS4USA Tel 1 305 436 0521 Fax 1 305 436 0528 D A S AUDIO ASIA PTE LTD 25 Kaki Bukit Crescent 01 00 02 00 Kaki Bukit Techpark 1 Singapore 416256 Tel 65 6742 0151 Fax 65 6742 0157 D A S AUDIO S A C Isl...

Reviews: