background image

INTRODUCTION

6

 

DASNET-SPLITTER

 and 

DASNET-SPLITTER-TR1

 are intended for the distribution of analog audio, 

monitoring  data  (

DASnet

)  and  power  to  multiple  devices,  with  simplicity.  The  first  uses 

PowerCon  NAC3MPB  output  mains  connectors,  and  the  second,  PowerCon  True1 
connectors.

 

For more information about 

DASnet

, typical configurations, 

DASNET-RACK

, or 

DASnet cables

 

see our website www.dasaudio.com.

 

The 

DASNET-SPLITTER

  (or  the 

DASNET-SPLITTER-TR1

)  is  a  steel  case  intended  for  the 

distribution of analog audio, monitoring data (

DASnet

) and power to multiple devices (the 

maximum number of units will depend on the system´s current consumption).

 

It includes one power input by means of one powercon true 1 connector (black-yellow) and 

one analog audio plus monitoring data input by the use of an ethercon connector.

 

It  includes  three  power  outputs  by  means  of  three  powercon  NAC3MPB  connectors 

(white), (PowerCon True1 in the 

DASNET-SPLITTER-TR1

) and three analog audio plus monitoring 

data outputs consisting of three ethercon connectors.

 

The main use of the splitter is with the 

LX-218CA-NET

 subwoofers. As the audio is routed in 

parallel inside the splitter never combine different speaker models in a single 

DASNET-SPLITTER

.

Features

OPEN

Manual del Usuario

 / DASnet Splitter / 

User’s Manual

CLOSE

CONNECT

eCP_xx cables

eCP_xx cables

eCP_xx cables

Summary of Contents for 20503060

Page 1: ... Antes de utilizar el equipo lea la sección Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions section of this manual Retainthismanualforfuturereference DASnet ...

Page 2: ...6 LX 218CA 12 AERO 40A 9 LX 218CA INTRODUCTION LINE DRAWINGS 3 4 5 10 9 11 SPECIFICATIONS ANNEX CONFIGURATIONS DASnet cables SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY Manual del Usuario DASnet Splitter User s Manual ...

Page 3: ...permanently the electrical system of the building must incorporate a multipolar switch with a separation of contact of at least 3mm in each pole Limpie con un paño seco No use limpiadores con disolventes Clean only with a dry cloth Do not use any solvent based cleaners No existen partes ajustables por el usuario en el interior de este equipo Cualquier operación de mantenimiento o reparación debe s...

Page 4: ...el comprador en todos los casos Para solicitar reparación en garantía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All our products are warrantied against any manufacturing defect for a period of 2 years from date of purchase The warranty excludes damage from incorrect use of the product All warranty repairs must be exclusive...

Page 5: ...or professional use Part 2 Immunity l EN 50581 2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Cumple con los objetivos esenciales de las Directivas Abide by essential objectives relating Directives l de Baja Tensión Low Voltage Directive 2014 35 UE l de Compatibilidad Electromagnética EMC 2014 30 UE l Ro...

Page 6: ...ximum number of units will depend on the system s current consumption It includes one power input by means of one powercon true 1 connector black yellow and one analog audio plus monitoring data input by the use of an ethercon connector It includes three power outputs by means of three powercon NAC3MPB connectors white PowerCon True1 in the DASNET SPLITTER TR1 and three analog audio plus monitorin...

Page 7: ... 4A RMS 2 x 40A 80A Peak 2 x LX 218CA NET 2 x 6 2A 12 4A RMS 2 x 40A 80A Peak 2 x LX 218CA NET 2 x 6 2A 12 4A RMS 2 x 40A 80A Peak 3 x AERO 40A 3 x 6A 18A RMS 3 x 16A 48A Peak 3 x AERO 40A 3 x 6A 18A RMS 3 x 16A 48A Peak 3 x AERO 40A 3 x 6A 18A RMS 3 x 16A 48A Peak 115V DASNET RACK maximum number of cabinets 9 AERO 40A 6 LX 218CA NET With these values in one phase we will have RMS current 3 x AERO...

Page 8: ...0A peak 60A 3 x LX 218CA NET 3 x 3 1A 9 3A RMS 3 x 20A peak 60A 3 x LX 218CA NET 3 x 3 1A 9 3A RMS 3 x 20A peak 60A 4 x AERO 40A 4 x 3A RMS 12A 4 x 16A peak 64A 4 x AERO 40A 4 x 3A RMS 12A 4 x 16A peak 64A 4 x AERO 40A 4 x 3A RMS 12A 4 x 16A peak 64A With these values in one phase we will have RMS current 4 x AERO 40A and 3 x LX 218CA NET 12A 9 3A RMS 21 3A RMS phase max RMS current is 32A Peak cu...

Page 9: ...15A Breakers type C 16A Breakers type D 20A Short term current peak 5In I 10In Short term current peak 10In I 20In 3A 6 2A 6A 20A 16A 40A 32A 230V 230V 115V 115V 230V 230V 115V 115V Important considerations Check the system s configurations AERO 20A AERO 40A for more information regarding the quantity of cabinets that should be connected to the DASNET SPLITTER Consider if you are using different p...

Page 10: ... DIMENSIONS IN MILLIMETERS ALL DIMENSIONS IN MILLIMETERS OPENED CLOSED Top View Top View Front View Front View Left View Left View Rear View Rear View Manual del Usuario DASnet Splitter User s Manual 250 276 206 65 250 197 ...

Page 11: ...to cable length The links between cabinets aero40A Convert15A LX 218CAnet which are STP CAT7 cables Cable code eC_09 Power Links between cabinets Cable code Plink1_09 Links for RoadNet series Power STP CAT7 eCPk_1 eCPk_5 The main feed cable eCP_xx has the following structure AL Shield 2 2 ecP_xx Power cable 3x2 5mm CAT7 4x 2 x 0 14mm Jacket Jacket STP CAT 7 cable with Aluminium Shield for each ind...

Page 12: ... 888 DAS 4 USA DAS Audio Asia PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 DAS Audio Group S L C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 34 96 134 0860 DAS do Brasil LTDA Rua Dos Andradas 382 SL Santa Efigênia São Paulo Brasil CEP 01208 000 Tel 551133330764 ...