background image

 

Motor Output Interface (MOI)

 

User & Installation Manual 

V2.0 

 

 

Summary of Contents for 80-911-0007-00

Page 1: ...Motor Output Interface MOI User Installation Manual V2 0...

Page 2: ...cations of either its products or associated documentation Translations In the event that there is a difference between a translation of this manual and the English version the English version should...

Page 3: ...nance And Repair 5 General Safety and Installation Precautions 5 3 OVERVIEW 6 Description 6 Features 6 MOI Hardware Overview 7 Led indicators 8 4 DESIGN 9 5 INSTALLATION 9 Things You Need 9 Environmen...

Page 4: ...s chapter 2 of this manual Please keep this manual in a secure place GUARANTEE SPECIFICATIONS BEP Marine guarantees that this unit has been built according to the legally applicable standards and spec...

Page 5: ...the MOI in locations where there is danger of gas or dust explosion or potentially flammable products 3 Use of the MOI other than mentioned in point 2 is not considered to be consistent with the inten...

Page 6: ...cables of up to 16 mm2 6AWG in size or multiple smaller conductors No need for specialized crimp terminals and expensive crimp tools to be carried for terminations to CZone just a blade screwdriver A...

Page 7: ...tput Circuit Fuses 12 Dipswitch 13 NMEA 2000 Connector 1 DC Power LED 2 Waterproof Cover 3 Circuit ID Labels 4 Protective Boot 5 Channel Status LEDs 6 Network Status LED 7 Module ID Label MOI HARDWARE...

Page 8: ...dule Not Configured 2 Red Flash Configuration Conflict 3 Red Flash DIP Switch Conflict 4 Red Flash Memory Failure 5 Red Flash No Modules Detected 6 Red Flash Low Run Current 7 Red Flash Over Current 8...

Page 9: ...f each connected load does not exceed maximum channel rating of 20A Install the appropriately rated fuses for each channel Loads exceeding 20A will require paralleling 2 channels together 5 INSTALLATI...

Page 10: ...cable grommet for wiring bend radius o Note Cable radius determined by wiring manufacturer 3 Fasten the MOI by using 4 x 8G or 10G 4mm or 5mm self tapping screws or bolts not supplied IMPORTANT The M...

Page 11: ...utput wires through cable grommet 2 Strip and insert each wire into the connector ensuring the correctly rated wire is used for each load and tighten screws to 4 43 in lbs 0 5NM 3 Insert plug firmly i...

Page 12: ...MAL bottom position of all circuits 3 The ATC fuse should be rated to protect the connected load and the wiring from the MOI to the load and also the ground wire MECHANICAL BYPASS The MOI includes a m...

Page 13: ...ve advanced functionality such as timers load shedding or one touch Modes of operation a custom configuration needs to be installed Set the dipswitch on the MOI to match the configuration file All oth...

Page 14: ...e purchased a label sheet WARNING The MOI is only ignition protected with the cover correctly installed INITIAL POWER UP 1 Power up the NMEA2000 Network system will flash all outputs for a short time...

Page 15: ...SYSTEM DIAGRAM EXAMPLES System Diagram BILGE PUMP BATTERY HATCH LIFTER NMEA 2000 NETWORK DC Negative Input DC Positive Input Reversible output pair CIRCUIT BREAKER Positive DC Output 1 Positive DC Out...

Page 16: ...0 5 6mm 24AWG 8AWG Output channels 1x 20A H Bridge channel 12 24 2 x 20A Output channels 12 24V Maximum current 60A Total Module Current Dimming Output channels PWM 100Hz Power supply M6 1 4 Positive...

Page 17: ...ssenger cars and light commercial vehicles with nominal 12 V supply voltage Electrical transient conduction along supply lines only ISO 7637 2 24V Commercial vehicles with nominal 24 V supply voltage...

Page 18: ...EN CZone Output Interface MOI User Installation Manual 18 8 Declaration of Conformity...