EN / CZone® Output Interface (MOI) User & Installation Manual
NETWORK CONFIGURATION
CZone modules communicate with each other over a NMEA2000 CAN BUS network. Each module needs a unique
address, this is achieved by carefully setting the dipswitch on each module with a small screwdriver. The dipswitch on
each module must match the setting in the CZone configuration. Refer to CZone Configuration Tool Manual on
instructions on creating and editing a CZone configuration.
•
To install the MOI with other networked CZone modules, or to achieve advanced functionality such as
timers, load shedding or one touch Modes of operation, a custom configuration needs to be installed.
•
Set the dipswitch on the MOI to match the configuration file.
•
All other CZone modules must have the dipswitch set to same as the configuration file.
The example below shows a dipswitch setting of 01101100 where 0 = OFF and 1 = ON
Setting Dipswitch
IMPORTANT -
Each CZone device must have a unique dipswitch number and the dipswitch of the device
must match the dipswitch set in the configuration file.