background image

KT01 KeyTouch Touchscreen Keypad 

 

15 

Control 

 

Clicking on the Control Menu brings the user to the following page: 

 

 

 

Here, the control lighting and other devices are shown.  The Master icon 
is used as a “master” control, which switches all the devices shown here 
on and off. Clicking on each individual appliance button brings out the 
chosen appliance page, allowing for individual control of individual 
devices. 
 
To program the buttons as such, double-click on any of the lights. It 
should bring up the following screen: 

 

Summary of Contents for KT01

Page 1: ...Comfort the Intelligent Home System KT01 KeyTouch Touchscreen Keypad ...

Page 2: ......

Page 3: ...m State 8 Battery State 9 Mains Failure 9 Tamper Status 10 Keypad Emulation 12 Control 15 Security 18 Panic 20 Others 22 Arming 22 Panic Status 23 Arm Ready Not Ready Status 23 Summary of Security Application Messages 24 Security Status Messages 24 Security Control Messages 25 Time and Date Synchronization 25 Summary of KeyTouch Default Program 26 Control 26 Lighting 26 Aircons 26 Heater 26 Master...

Page 4: ......

Page 5: ...d alarm information from Comfort It includes a speaker and microphone to record and broadcast voice messages as well as an infrared receiver to activate any Response in a similar to KP02 and KP04 The LCD display can be set to rotate 180 o to allow for the choice of the user to have the IR receiver positioned above or below the LCD With KeyTouch the user is able to have his own personalized menu by...

Page 6: ... KeyTouch Manual this booklet KeyTouch C Touch configuration CD mounting screws in polybag Subject to change without prior notice Connections JP3 12V COM KA KB VOICE MIC IR connector Connected to 12V COM KA KB VOICE MIC on Comfort and IR cable linked to IR receiver P3 6 way header To be connected to when in normal mode P4 6 way header To be connected to when in programming mode P5 DB9 connector Fo...

Page 7: ...UCMs KeyTouch SW2 is a set of 3 headers which is used to determine the ID in accordance to the table below Table 1 ID Settings ID SW2 A SW2 B SW2 C 1 Short Short Short 2 Open Short Short 3 Short Open Short 4 Open Open Short 5 Short Short Open 6 Open Short Open 7 Short Open Open 8 Open Open Open By convention UCM ID 1 is used for uploading downloading The KeyTouch UCM should be set to ID 2 or above...

Page 8: ...well as to provide for the voice prompt and allow for voice recordings on the KT01 end This is connected to KT01 at JP3 3 The Infrared receiver is connected to JP3 via a cable 4 The Green RDY LED on the KT01 D1 should be lit and remain steady indicating power is supplied to the KT01 The LEDs D8 red and D9 green should blink rapidly showing that RS485 is established between Comfort and KT01 D8 red ...

Page 9: ...e programming This can be downloaded from Clipsal s website at www clipsal com cis The above screen should be seen when running the installation for the C Touch Configuration software Follow the instructions on the screen to complete setup The C Bus C Touch software which is used to customize and program the KeyTouch is a user friendly drag and drop interface which will be explained in greater det...

Page 10: ...n date and time for Comfort and similarly for Comfort any change in date and time for KeyTouch will change the time for Comfort The Battery Arm State and Alarm State icons as well as text indicators for Tamper Alarm and AC Failure indicate the current status of Comfort A Low Battery condition will result in a change of the battery icon from to When Comfort is armed be it Away Night Day or Vacation...

Page 11: ...ous statuses shown on the main page is depicted Arm Status This status shows the current arm status but does not show the security mode The icon is used is a lock and its status is reflected as such System is disarmed System is armed This status utilizes the Security Application To program the status double click on the lock icon to bring up the following page after selecting C Bus tab ...

Page 12: ...s Status Network Local Network Application D0 Group Address 80 Alarm State This icon serves to show when the system is in Alarm System is not in alarm idle trouble or alert System is in alarm To program the status double click on the lock icon to bring up the following page after selecting C Bus tab ...

Page 13: ... statuses double click on the battery icon To reflect the battery status the following must be set Key functions Status Network Local Network Application D0 Group Address 8B Mains Failure The default KeyTouch program uses the Text Font Status to indicate the mains status AC OK for mains normal AC FAIL for mains failure situations Programming the mains status is similar to the previous statuses dou...

Page 14: ...ses with the following settings Key functions Status Network Local Network Application D0 Group Address 84 In the default program the text font status indication is used Here when there is no tamper alarm the text will show No Tamper font size 9 normal However when a Tamper alarm is triggered the text will change to TAMPER all in capital letters font size 12 bold ...

Page 15: ...KT01 KeyTouch Touchscreen Keypad 11 ...

Page 16: ...user coder will disarm the system The voice menu can be heard like a normal keypad as well F2 will go into the Home Control Menu and allow the user to control the lights and appliances Pressing F exits the voice menu The Component Properties page is shown in the following figure In the KeyTouch programming software double click on the key or button to access the Component Properties page Click on ...

Page 17: ...ulate the keypad keys set the following parameters Application D0 Key Function Preset Tag Level corresponding to the keypad digit see Table 2 Ramp Rate instantaneously The following table illustrates the relationship between the Tag values and the keypad keys ...

Page 18: ...arm 82 Fire Hard Key Triggers fire alarm 83 Night Hard Key Arms to Night mode 84 Away Vacation Hard Key Arms to Away Vacation mode 85 Night Hard Key Arms to Night mode 86 Day Hard Key Arms to Day mode 87 Away Vacation Hard Key Arms to Away Vacation mode 91 Away Function Key Simulates Away Function on keypad UCM CBUS 5 60 92 Night Function Key Simulates Night Function on keypad UCM CBUS 5 60 93 Day...

Page 19: ...ices are shown The Master icon is used as a master control which switches all the devices shown here on and off Clicking on each individual appliance button brings out the chosen appliance page allowing for individual control of individual devices To program the buttons as such double click on any of the lights It should bring up the following screen ...

Page 20: ...rt as well For instance if a light button is programmed to be group address 01 the corresponding counter is 01 and must have its response programmed to activate the desired outcome For example using action codes to turn on Output 5 when a light button of group address 01 is pressed the response can be written as such Response 31 70 128 128 05 01 255 Here 31 gets the counter value of the last count...

Page 21: ...ad 17 Similarly it can also be programmed in Comfigurator via the following If LastUcmCounter 128 Then Output Output05 On End If The counter responses can also be programmed in Comfigurator by selecting Counters under the Events tab ...

Page 22: ...s front door PIR 2 windows and a door as well as the security status of the tamper alarm battery arm status and AC status To select the zones to be monitor double click on any zones then clicking on C Bus Tab which will bring up the following page Then select the following Key Functions Status Network Local Network Application 01 Group Address determined by the zone number 01 for zone 1 02 for zon...

Page 23: ...KT01 KeyTouch Touchscreen Keypad 19 Under the Visual Properties Tab the visual appearance for the button can be customized to display the zone status when the zone is on or off ...

Page 24: ...licking on the Panic button on the main page brings the user to the following screen Here pressing the panic button will result in a Panic alarm in Comfort To program the button to do this double click on the Panic button and go to the C Bus Tab ...

Page 25: ...KeyTouch Touchscreen Keypad 21 Here set the following Key Functions On as one cannot stop a Panic alarm by simply turning it off Network Local Network Application D0 security Group Address A4 Activate alarm ...

Page 26: ...ouch program These include arming panic status and arm ready not ready status Arming This allows the user to arm the system in the desired mode To do so create a button and double click on it selecting C Bus tab which will bring up the following page The parameters to set are as follow Key Functions Preset Network Local Network Application D0 Group Address A2 Tag 01 for away 02 for night 03 for da...

Page 27: ...ton It must be cleared by disarming the system Arm Ready Not Ready Status This is used to inform the user whether the system is ready to be armed or not i e when there are opened monitored zones To program for such a display a button or a text display can be created with the following settings set for the C Bus settings under its Component Properties Key Functions Dimmer Network Local Network Appl...

Page 28: ...on Zone sealed 87 Not implemented Zone open circuit 88 Not implemented Zone short circuit 89 Not implemented Zone Isolated 8A Not used for KeyTouch Battery 8B Status Low ON OK OFF Battery Charging 8C Not implemented Zone Name 8D Not implemented Status Report 1 8E Not used for KeyTouch Status Report 2 8F Not used for KeyTouch Password Entry 90 1 Valid 2 Invalid See Note 3 Disabled 4 re enabled not ...

Page 29: ...n Off Activate Alarm Panic A4 On Keypad Emulation A5 Preset Instantaneous Keypad digit Display Messages A6 Not implemented Request Zone Name A7 Not implemented Time and Date Synchronization When the date and time is changed via KeyTouch it is similarly updated in Comfort and vice versa In Comfort enter the user code go into Program menu user menu 9 then select 2 to change date and time Changes in ...

Page 30: ... 01 Dining 02 Mbedrm 03 Bedrm1 On off Lighting 04 Heater Device Key Function Application Group Address Heater On off Lighting 1E Aircons Device Key Function Application Group Address Living 10 Dining 11 Mbedrm 12 Bedrm 1 13 Bedrm 2 On off Lighting 14 Master Device Key Function Application Group Address Master On off Lighting 17 Security Zones Zones Device Key Function Application Group Address Fro...

Page 31: ... 128 Comfort IR codes numbered 0 to 127 Each of these IR codes can trigger a response to be activated In Comfigurator go to IR Receive Codes under Events For each IR code number a Response can be selected for activation when the IR code is received The IR Responses can also be programmed in the Locations Menu Engineer Menu 7 4 1 Refer to Table 36A in the relevant Worksheet for File System 18 Pro o...

Page 32: ...KT01 KeyTouch Touchscreen Keypad 28 Version History N A ...

Page 33: ...KT01 KeyTouch Touchscreen Keypad 29 ...

Page 34: ...hscreen Keypad 30 Document Title Comfort KeyTouch UCM C Bus Firmware 5 75 and above Date Last Modified 10 December 2004 KeyTouch Firmware 1 82 or above Comfort Version Outside 4 193 and above Comfigurator 1 50 and above ...

Reviews: