Specifications

Physical 

Dimensions

2.34 x 1.40 x 0.50 inches (excluding wires), wires are approx. 10 
inches long

Environmen
tal

Temperature Range (Storage)

-55°C to +150°C

Temperature Range (Operating)

-40°C to +80°C 

Humidity

95 percent (non-condensing)

Electrical

Input

Unreg Input 6 to 30 Vdc @ 50mA

 

Typical (200mA max)

Data I/O

Wiegand Output

Maximum 255 bits 

OSDP 

Conforms to Open Supervised Device Protocol (OSDP™) v2.2.0 
and IEC Committee Draft Version 60839-11-5

Ordering
Information

Part Number: OSM-CPI

UPC: 816684002540

Agency 
Approval

CE Certified: Certified to EN 61000-6-3

SIA’s Open Supervised Device Protocol (OSDP) 

v2.2.0 communication standard benefits

Security: OSDP Secure Channel halts Wiegand hacking with AES-128 encryption

Interoperability: Mix and match devices to help future-proof systems

Functionality: 2-way communication, access control that withstands the elements, 
multi-drop installations, 2 wires instead of 10+

Communication: With OSDP’s 2-way communication, the panel can query readers 
to find out capabilities, without physically reconfiguring devices. The panel is alerted 
if the reader does not answer its query.

Savings: OSDP is scalable. It supports many more devices – and many more types 
of devices (such as readers, strike sensors and alarms) – than the Wiegand protocol.

Learn more at OSDP-Connect.com or CypressIntegration.com/OSDP

The OSM-CPI is a dedicated OSDP to legacy Wiegand control panel interface. The unit converts 
credential data from an OSDP reader to Wiegand to direct to the control panel, and converts the 
controller’s signal I/O to an OSDP message to send back to the reader. Credential data is sent over an 
encrypted OSDP connection.

Cypress OSM-CPI - Product Overview and Specifications

Summary of Contents for OSM-CPI

Page 1: ...by the Security Industry Association SIA to improve interoperability among access control and security products OSDP v2 1 7 is currently in process to become a standard recognized by the IEC internati...

Page 2: ...atch devices to help future proof system s Functionality 2 way communication access control that withstands the elements multi drop installations 2 wires instead of 10 Communication With OSDP s 2 way...

Page 3: ...and Speci fi cations 2 Parts list Cable recommendations Signals and pinout 3 Physical Dimensions and Mounting Hole Locations 3 Setup and Pre Installation 5 Indicators and Operating Modes 6 7 Troubles...

Page 4: ...ace The signals of the terminal blocks and fl ying leads are named according to the diagram below Cypress OSM CPI Parts Wiring Signals and Pinout Cypress OSM CPI Physical Dimensions and Mounting Hole...

Page 5: ...de lead to ground before power up The OSM CPI will initiate a secure channel session using SCBK_D then issue an osdp_KEYSET command with a new random key From then on during normal operation the OSM C...

Page 6: ...eceives an incorrect reply or a reply is never received the unit will restart the connection sequence from the beginning At this point to initiate a secure channel session with the attached PD the OSM...

Page 7: ...led in the following Keypad Table Cypress OSM CPI Indicators and Operating Modes Meaning Diagnostic LED Behavior Power On Sequence Cycling though various solid colors 0 5 s color ACU Mode unsuccessful...

Page 8: ...t An OSM CPI connected to a compatible peripheral device can both be restored to a factory default state by shorting the purple fl ying lead to ground and shorting the green fl ying lead to the yellow...

Reviews: