Document Number: 002-04713 Rev.*A
Page 53 of 65
MB96640 Series
1LSB (Ideal value) =
AVRH - AVRL
[V]
1024
Total error of digital output N =
V
NT
- {1LSB
(N - 1) + 0.5LSB}
1LSB
N
: A/D converter digital output value.
V
NT
: Voltage at which the digital output changes from 0x (N + 1) to 0xN.
V
OT
(Ideal value) = AVRL + 0.5LSB[V]
V
FST
(Ideal value) = AVRH - 1.5LSB[V]