MB95310L/370L Series
Document Number: 002-07519 Rev. *A
Page 48 of 80
18.4
AC Characteristics
18.4.1
Clock Timing
(V
CC
= 3.0 V
10%, V
SS
= 0.0 V, T
A
=
40
C to
85
C)
Parameter
Symbol Pin name Condition
Value
Unit
Remarks
Min
Typ
Max
Clock frequen-
cy
F
CH
X0, X1
—
1.00
—
16.25
MHz
When the main oscillation circuit is used
1.00
—
32.50
MHz
When the main external clock is used
3.00
—
8.13
MHz
Main PLL multiplied by 2
3.00
—
6.5
MHz
Main PLL multiplied by 2.5
3.00
—
4.06
MHz
Main PLL multiplied by 4
F
CRH
—
12.25
12.5
12.75
MHz
Operating conditions:
• The main CR clock is used.
• T
A
=
10
C to
85
C
9.8
10
10.2
MHz
7.84
8
8.16
MHz
0.98
1
1.02
MHz
—
12.1875
12.5
12.8125
MHz
Operating conditions:
• The main CR clock is used.
• T
A
=
40
C to
10
C
9.75
10
10.25
MHz
7.8
8
8.2
MHz
0.975
1
1.025
MHz
F
CL
X0A, X1A
—
32.768
—
kHz
When the sub-oscillation circuit is used
—
32.768
—
kHz
When the sub-external clock is used
F
CRL
—
50
100
200
kHz
When the sub-CR clock is used
Clock cycle
time
t
HCYL
X0, X1
—
61.5
—
1000
ns
When the main oscillation circuit is used
30.8
—
1000
ns
When the external clock is used
t
LCYL
X0A, X1A
—
30.5
—
µs
When the subclock is used
Input clock
pulse width
t
WH1
t
WL1
X0
—
61.5
—
—
ns
When using external clock and the duty ra-
tio is about 30% to 70%
t
WH2
t
WL2
X0A
—
15.2
—
µs
Input clock rise
time and fall
time
t
CR
t
CF
X0, X0A
X1: open
—
—
5
ns
When the external clock is used
CR oscillation
start time
t
CRHWK
—
—
—
—
150
µs
When the main CR clock is used
t
CRLWK
—
—
—
—
10
µs
When the sub-CR clock is used