5.2.7 Motor1_Kj
Data type: float
Description: PMSM moment of inertia
Unit: Kg·m2
5.2.8 Motor1_dki
Data type: float
Description: D axis current loop integral parameter
Unit: none
Range: about 0.3
5.2.9 Motor1_dkp
Data type: float
Description: D axis current loop proportion parameter
Unit: none
Range: about 0.3
5.2.10 Motor1_qki
Data type: float
Description: Q axis current loop integral parameter
Unit: none
Range: about 0.3
5.2.11 Motor1_qkp
Data type: float
Description: Q axis current loop proportion parameter
Unit: none
Range: about 0.3
5.2.12 Motor1_ski
Data type: float
Description: Speed loop integral parameter
Unit: none
Range: about 0.0005
5.2.13 Motor1_skp
Data type: float
Description: Speed loop proportion parameter
Unit: none