![Cypress CPHD-3 Operation Manual Download Page 22](http://html.mh-extra.com/html/cypress/cphd-3/cphd-3_operation-manual_2705991022.webp)
Application
This is used to locate faulty linearity of the video amplifier or greyscale
setting. Nonlinearities mainly result in a compression of the white level.
Bl
a
ck
W
hi
te
L
in
e
P19
Vertical BW1 (black 1 pixel, white 1 pixel)
P20
Vertical BW12(black 12 pixels, white 12
pixels)
P21
Horizontal BW1(black 1 pixel, white 1 pixel)
P22
Horizontal BW3(black 3 pixels, white 3
pixels)
P23
Horizontal BW6(black 6 pixels, white 6
pixels)
P24
Multi-Burst BW6+BW3+BW2+BW1
Application
The Vertical pattern serves for a quick check of a color monitor’s horizontal
bandwidth and phase behavior of a video transmission. It also, verify video
amplifier and color temperature.
The Horizontal pattern serves for a quick check of color monitor’s vertical
bandwidth and
phase behavior of a video transmission. It also, verify video amplifier and
color temperature.
PL
UG
E
P25
Picture Line-Up Generation Equipment
Press [OPTION] to select color range
Full Range=0~255, Limited Range=16~235
PC/HD output gets Full Range=0%~100%
Application
PLUGE is used to perform accurate and consistent line-up of picture
monitors. The usual procedure is to adjust the brightness control of a
monitor so that bar 1 is invisible on the background while bar 2 can be still
distinguished. The white level luminance is mainly
adjusted by the contrast control to 70 ±10 cd/m2 by means of the upper
100% white area of the vertical grayscale.
18