Cypress Suprex® RF Series - Accessory I/O - Relay 3 & 4 I/O
Relay 4 I/O Diagram
+8 to +16 VDC
Ground
exp(+)
exp(-)
+5V Out
P R 4
P R 3
LED In
D1/Data Out
D0/Clock Out
Relay 4 N.O.
Relay 4 Com
Relay 4 N.C.
Relay 3 N.O.
Relay 3 Com
Relay 3 N.C.
Ground
Aux Output
Relay 2 Input
Relay 1 Input
Central
+8 to +16 VDC
Ground
exp(+)
exp(-)
+5V Out
P R 4
P R 3
LED In
D1/Data Out
D0/Clock Out
Relay 4 N.O.
Relay 4 Com
Relay 4 N.C.
Relay 3 N.O.
Relay 3 Com
Relay 3 N.C.
Ground
Aux Output
Relay 2 Input
Relay 1 Input
Central
+8 to +16 VDC
Ground
exp(+)
exp(-)
+5V Out
Relay 4 Input
Relay 3 Input
LED Out
D1/Data In
D0/Clock In
Relay 2 N.O.
Relay 2 Com
Relay 2 N.C.
Relay 1 N.O.
Relay 1 Com
Relay 1 N.C.
Ground
Aux Input
Not Used
Not Used
Remote
+8 to +16 VDC
Ground
exp(+)
exp(-)
+5V Out
Relay 4 Input
Relay 3 Input
LED Out
D1/Data In
D0/Clock In
Relay 2 N.O.
Relay 2 Com
Relay 2 N.C.
Relay 1 N.O.
Relay 1 Com
Relay 1 N.C.
Ground
Aux Input
Not Used
Not Used
Remote
Relay 3 I/O Diagram
+8 to +16 VDC
Ground
exp(+)
exp(-)
+5V Out
P R 4
P R 3
LED In
D1/Data Out
D0/Clock Out
Relay 4 N.O.
Relay 4 Com
Relay 4 N.C.
Relay 3 N.O.
Relay 3 Com
Relay 3 N.C.
Ground
Aux Output
Relay 2 Input
Relay 1 Input
Central
+8 to +16 VDC
Ground
exp(+)
exp(-)
+5V Out
P R 4
P R 3
LED In
D1/Data Out
D0/Clock Out
Relay 4 N.O.
Relay 4 Com
Relay 4 N.C.
Relay 3 N.O.
Relay 3 Com
Relay 3 N.C.
Ground
Aux Output
Relay 2 Input
Relay 1 Input
Central
+8 to +16 VDC
Ground
exp(+)
exp(-)
+5V Out
Relay 4 Input
Relay 3 Input
LED Out
D1/Data In
D0/Clock In
Relay 2 N.O.
Relay 2 Com
Relay 2 N.C.
Relay 1 N.O.
Relay 1 Com
Relay 1 N.C.
Ground
Aux Input
Not Used
Not Used
Remote
+8 to +16 VDC
Ground
exp(+)
exp(-)
+5V Out
Relay 4 Input
Relay 3 Input
LED Out
D1/Data In
D0/Clock In
Relay 2 N.O.
Relay 2 Com
Relay 2 N.C.
Relay 1 N.O.
Relay 1 Com
Relay 1 N.C.
Ground
Aux Input
Not Used
Not Used
Remote
This diagram shows how
the state of the the Relay 3
Outputs change the as
Relay 3 Input is set to
0Volts (connected to
Ground) using a jumper
connection. The left side
shows that when Relay 3
Input is not set to 0Volts,
Relay 3 COM and Relay 3
N.C have continuity. The
right side shows that when
Relay 3 Input is set to
0Volts, Relay 3 COM and
Relay 3 N.O. have
continuity.
This diagram shows how
the state of the the Relay 4
Outputs change the as
Relay 4 Input is set to
0Volts (connected to
Ground) using a jumper
connection. The left side
shows that when Relay 4
Input is not set to 0Volts,
Relay 4 COM and Relay 1
N.C have continuity. The
right side shows that when
Relay 4 Input is set to
0Volts, Relay 4 COM and
Relay 4 N.O. have
continuity.