STK11C88
Document Number: 001-50591 Rev. **
Page 6 of 15
Maximum Ratings
Exceeding maximum ratings may shorten the useful life of the
device. These user guidelines are not tested.
Storage Temperature ................................. –65
°
C to +150
°
C
Temperature under bias .............................. –55
°
C to +125
°
C
Supply Voltage on V
CC
Relative to GND.......... –0.5V to 7.0V
Voltage on Input Relative to Vss ............–0.6V to V
CC
+ 0.5V
Voltage on DQ
0-7
...................................–0.5V to Vcc + 0.5V
Power Dissipation ......................................................... 1.0W
DC Output Current (1 output at a time, 1s duration).... 15 mA
Operating Range
Range
Ambient Temperature
V
CC
Commercial
0
°
C to +70
°
C
4.5V to 5.5V
Industrial
-40
°
C to +85
°
C
4.5V to 5.5V
DC Electrical Characteristics
Over the operating range (V
CC
= 4.5V to 5.5V)
Parameter
Description
Test Conditions
Min
Max
Unit
I
CC1
Average V
CC
Current t
RC
= 25 ns
t
RC
= 45 ns
Dependent on output loading and cycle rate.
Values obtained without output loads.
I
OUT
= 0 mA.
Commercial
97
70
mA
mA
Industrial
100
70
mA
mA
I
CC2
Average V
CC
Current
during STORE
All Inputs Do Not Care, V
CC
= Max
Average current for duration t
STORE
3
mA
I
CC3
Average V
CC
Current
at t
RC
= 200 ns, 5V,
25°C Typical
WE > (V
CC
– 0.2V). All other inputs cycling.
Dependent on output loading and cycle rate. Values obtained
without output loads.
10
mA
I
SB1
[3]
Average V
CC
Current
(Standby, Cycling
TTL Input Levels)
t
RC
=25ns, CE > V
IH
t
RC
=45ns, CE > V
IH
Commercial
30
22
mA
Industrial
31
23
mA
I
SB2
[3]
V
CC
Standby Current
(Standby, Stable
CMOS Input Levels)
CE > (V
CC
– 0.2V). All others V
IN
< 0.2V or > (V
CC
– 0.2V).
750
μ
A
I
IX
Input Leakage
Current
V
CC
= Max, V
SS
< V
IN
< V
CC
-1
+1
μ
A
I
OZ
Off State Output
Leakage Current
V
CC
= Max, V
SS
< V
IN
< V
CC
, CE or OE > V
IH
or WE < V
IL
-5
+5
μ
A
V
IH
Input HIGH Voltage
2.2
V
CC
+
0.5
V
V
IL
Input LOW Voltage
V
SS
–
0.5
0.8
V
V
OH
Output HIGH Voltage I
OUT
= –4 mA
2.4
V
V
OL
Output LOW Voltage I
OUT
= 8 mA
0.4
V
Data Retention and Endurance
Parameter
Description
Min
Unit
DATA
R
Data Retention
100
Years
NV
C
Nonvolatile STORE Operations
1,000
K
Note
3. CE > V
IH
will not produce standby current levels until any nonvolatile cycle in progress has timed out.
[+] Feedback