Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with
Power Applied............................................. –55°C to +125°C
Supply Voltage on V
CC
Relative to GND
[2]
... –0.5V to + 4.6V
DC Voltage Applied to Outputs
[6]
in High-Z State .......................................–0.5V to V
CC
+ 0.5V
DC Input Voltage
[2]
.................................–0.5V to V
CC
+ 0.5V
Current into Outputs (LOW)......................................... 20 mA
Static Discharge Voltage........................................... > 2001V
(per MIL-STD-883, Method 3015)
Latch-up Current..................................................... > 200 mA
Selection Guide
-10
-12
-15
Unit
Maximum Access Time
10
12
15
ns
Maximum Operating Current
Comm’l
90
85
80
mA
Ind’l
85
mA
Maximum Standby Current
5
5
5
mA
Operating Range
Range
Ambient Temperature
V
CC
Commercial
0°C to +70°C
3.3V
±
10%
Industrial
–40°C to +85°C
3.3V
±
10%
Electrical Characteristics
Over the Operating Range
Parameter
Description
Test Conditions
–10
–12
–15
Unit
Min.
Max.
Min.
Max.
Min.
Max.
V
OH
Output HIGH Voltage V
CC
= Min.,
I
OH
= – 4.0 mA
2.4
2.4
2.4
V
V
OL
Output LOW Voltage V
CC
= Min.,
I
OL
= 8.0 mA
0.4
0.4
0.4
V
V
IH
Input HIGH Voltage
2.0
V
CC
+ 0.3
2.0
V
CC
+ 0.3
2.0
V
CC
+ 0.3
V
V
IL
Input LOW Voltage
[2]
–0.3
0.8
–0.3
0.8
–0.3
0.8
V
I
IX
Input Leakage
Current
GND < V
I
< V
CC
–1
+1
–1
+1
–1
+1
µ
A
I
OZ
Output Leakage
Current
GND < V
I
< V
CC
,
Output Disabled
–1
+1
–1
+1
–1
+1
µ
A
I
CC
V
CC
Operating
Supply Current
V
CC
= Max.,
I
OUT
= 0 mA,
f = f
MAX
= 1/t
RC
Comm’l
90
85
80
mA
Ind’l
85
mA
I
SB1
Automatic CE
Power-down Current
—TTL Inputs
Max. V
CC
, CE > V
IH
V
IN
> V
IH
or
V
IN
< V
IL
, f = f
MAX
Comm’l
15
15
15
mA
Ind’l
15
mA
I
SB2
Automatic CE
Power-down Current
—CMOS Inputs
Max. V
CC
,
CE > V
CC
– 0.3V,
V
IN
> V
CC
– 0.3V,
or V
IN
< 0.3V, f = 0
Comm’l
5
5
5
mA
Ind’l
5
mA
Capacitance
[3]
Parameter
Description
Test Conditions
Max.
Unit
C
IN
Input Capacitance
T
A
= 25°C, f = 1 MHz,
V
CC
= 3.3V
8
pF
C
OUT
Output Capacitance
8
pF
Notes:
2.
V
IL
(min.) = –2.0V for pulse durations of less than 20 ns.
3.
Tested initially and after any design or process changes that may affect these parameters.
[+] Feedback