Maximum Ratings

(Above which the useful life may be impaired. For user guide-
lines, not tested.)

Storage Temperature  ................................. –65°C to +150°C

Ambient Temperature with
Power Applied............................................. –55°C to +125°C

Supply Voltage on V

CC

 Relative to GND

[2]

... –0.5V to + 4.6V

DC Voltage Applied to Outputs

[6]

in High-Z State .......................................–0.5V to V

CC

 + 0.5V

DC Input Voltage

[2]

.................................–0.5V to V

CC

 + 0.5V

Current into Outputs (LOW)......................................... 20 mA

Static Discharge Voltage........................................... > 2001V
(per MIL-STD-883, Method 3015)

Latch-up Current..................................................... > 200 mA

Selection Guide

-10

-12

-15

Unit

Maximum Access Time

10

12

15

ns

Maximum Operating Current

Comm’l

90

85

80

mA

Ind’l

85

mA

Maximum Standby Current

5

5

5

mA

Operating Range

Range

Ambient Temperature

V

CC

Commercial

0°C to +70°C 

3.3V 

±

 10%

Industrial

–40°C to +85°C 

3.3V 

±

 10%

Electrical Characteristics 

Over the Operating Range

Parameter

Description

Test Conditions

–10

–12

–15

Unit

Min.

Max.

Min.

Max.

Min.

Max.

V

OH

Output HIGH Voltage V

CC

 = Min., 

I

OH

 = – 4.0 mA

2.4

2.4

2.4

V

V

OL

Output LOW Voltage V

CC

 = Min., 

I

OL

 = 8.0 mA

0.4

0.4

0.4

V

V

IH

Input HIGH Voltage

2.0

V

CC

 + 0.3

2.0

V

CC

 + 0.3

2.0

V

CC

 + 0.3

V

V

IL

Input LOW Voltage

[2]

–0.3

0.8

–0.3

0.8

–0.3

0.8

V

I

IX

Input Leakage 
Current

GND < V

I

 < V

CC

–1

+1

–1

+1

–1

+1

µ

A

I

OZ

Output Leakage
Current

GND < V

< V

CC

,

Output Disabled

–1

+1

–1

+1

–1

+1

µ

A

I

CC

V

CC

 Operating 

Supply Current

V

CC

 = Max.,

 

I

OUT

 = 0 mA,

f = f

MAX

 = 1/t

RC

Comm’l

90

85

80

mA

Ind’l

85

mA

I

SB1

Automatic CE 
Power-down Current
—TTL Inputs

Max. V

CC

, CE > V

IH

V

IN

 > V

IH

 or 

V

IN

 < V

IL

, f = f

MAX

Comm’l

15

15

15

mA

Ind’l

15

mA

I

SB2

Automatic CE 
Power-down Current
—CMOS Inputs

Max. V

CC

CE > V

CC

 – 0.3V,

V

IN

 > V

CC

 – 0.3V,

or V

IN

 < 0.3V, f = 0

Comm’l

5

5

5

mA

Ind’l

5

mA

Capacitance

[3]

Parameter

Description

Test Conditions

Max.

Unit

C

IN

Input Capacitance

T

A

 = 25°C, f = 1 MHz,

V

CC

 = 3.3V

8

pF

C

OUT

Output Capacitance

8

pF

Notes:

2.

V

IL

 (min.) = –2.0V for pulse durations of less than 20 ns.

3.

Tested initially and after any design or process changes that may affect these parameters.

[+] Feedback 

Summary of Contents for CY7C1018CV33

Page 1: ...cation specified on the address pins A0 through A16 Reading from the device is accomplished by taking Chip Enable CE and Output Enable OE LOW while forcing Write Enable WE HIGH Under these conditions...

Page 2: ...Conditions 10 12 15 Unit Min Max Min Max Min Max VOH Output HIGH Voltage VCC Min IOH 4 0 mA 2 4 2 4 2 4 V VOL Output LOW Voltage VCC Min IOL 8 0 mA 0 4 0 4 0 4 V VIH Input HIGH Voltage 2 0 VCC 0 3 2...

Page 3: ...for all speeds are tested using the Th venin load shown in Figure a High Z characteristics are tested for all speeds using the test load shown in Figure c 5 Test conditions assume signal transition ti...

Page 4: ...r to or coincident with CE transition LOW 14 Data I O is high impedance if OE VIH 15 If CE goes HIGH simultaneously with WE going HIGH the output remains in a high impedance state PREVIOUS DATA VALID...

Page 5: ...VALID CE ADDRESS WE DATA I O OE NOTE 16 DATA VALID tHD tSD tLZWE tPWE tSA tHA tAW tSCE tWC tHZWE CE ADDRESS WE DATA I O NOTE 16 Truth Table CE OE WE I O0 I O7 Mode Power H X X High Z Power down Stand...

Page 6: ...ents in life support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user The inclusion of Cypress products in life support systems application...

Page 7: ...Loads split based on speed B 115046 05 30 02 HGK ICC and ISB1 modified C 116476 09 16 02 CEA Add applications foot note on data sheet pg 1 D 493543 See ECN NXR Added Industrial Operating Range Removed...

Reviews: