![CYP XA-4 Operator'S Manual Download Page 51](http://html1.mh-extra.com/html/cyp/xa-4/xa-4_operators-manual_2705077051.webp)
51
COMMANDS
DESCRIPTION
VARIABLES
$EDID_NAME N1,N2
Set the EDID name of the selected copy
slot.
N1
= C1 ~ C10
N2
= {Name}
[20 characters max]
$EDID_NAME? N1
Display the name of the selected EDID
slot.
N1
= D1 ~ D10, C1 ~ C10
$EDID_NATIVE? N1
Display the native resolution value
stored in the EDID of the selected
location.
Available values for
N1
:
RX
[HDMI Input (Rx) Port]
SINK_H
[HDMI
Sink]
SINK_V
[VGA
Sink]
!
First detailed timing from Block 0.
If the EDID fails to be read, "$err_ddc" will be displayed.
If the EDID has invalid content, "$err_bad" will be displayed.
$EDID_READ N1,N2
Displays the selected data block stored
in the EDID of the selected location.
Available values for
N1
:
D1 ~ D10
[Default EDID 1 ~ 10]
C1 ~ C10
[Copy EDID 1 ~ 10]
SINK_H
[HDMI
Sink]
SINK_V
[VGA
Sink]
Available values for
N2
:
BLOCK0
[EDID Block 0]
BLOCK1
[EDID Block 1]
BLOCK2
[EDID Block 2]
BLOCK3
[EDID Block 3]
!
This data is output as a bit stream of 128 bytes following the <CR><LF> of the
command acknowledgement.
Each hex data unit is composed of 3 digits. The first 2 digits are the hex value. The 3rd
digit is a space (0x20).
Blocks 2 & 3 are only supported from the HDMI Sink.
If the EDID fails to be read, "$err_ddc" will be displayed.
If block 2 or block 3 doesn’t exist, “$err_block” will be displayed.