background image

21

7. CONNECTION DIAGRAM

TX

RX

OPTICAL

AUDIO

LAN(POE)

RS-232

TX RX

DC 5V

OUT

R

L

G

OPTICAL

LINE

IN

MIC

RS-232

LAN(POE)

TX RX

DC 5V

Blu-ray Player

Network Switch

Blu-ray Player

Microphone  RS-232 Equipped

PC/Latop

Power

Supply

Power

Supply

Powered 

Speakers

Powered 

Speakers

RS-232 Controllable Unit

C

M

Y

CM

MY

CY

CMY

K

CH-A320TXRX_Connection_Diagram.pdf   1   12/05/2022   11:26

Summary of Contents for IP-A750RX

Page 1: ...IP A750RX Audio over IP Receiver for IP 7000 series OPERATION MANUAL ...

Page 2: ......

Page 3: ... reserves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored in a retrieval system or any of its part translated into any language or computer file in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without express writte...

Page 4: ... into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To protect the unit from overheating...

Page 5: ...Panel 3 6 2 Rear Panel 4 6 3 RS 232 Pinout 4 6 4 WebGUI Control 5 6 4 1 System Tab 7 6 4 2 Network Tab 10 6 4 3 Functions Tab 12 6 5 Telnet Control 14 6 6 Serial and Telnet Commands 14 7 Connection Diagram 21 8 Specifications 22 8 1 Technical Specifications 22 8 2 Audio Specifications 23 8 2 1 Digital Audio 23 8 2 2 Analogue Audio 23 9 Acronyms 24 ...

Page 6: ...ompatible audio transmission devices located anywhere on the local network Standard control is provided by front panel controls WebGUI and Telnet Advanced control and system integration is possible using the optional IP Master Controller 2 APPLICATIONS Home Theaters Classrooms Lecture Halls 3 PACKAGE CONTENTS 1 Audio over IP Receiver 1 5V 1 2A DC Power Adapter 1 3 pin Terminal Block 1 5 pin Termin...

Page 7: ...abit network switches Volume control for the analogue audio output Compatible with the IP Master Controller to allow integration with existing compatible TCP IP video matrix networks Field upgradable firmware May be powered directly by Power over Ethernet PoE when connected to a Gigabit Ethernet switch that provides PoE 802 3af Standard control is provided by front panel controls WebGUI and Telnet...

Page 8: ...tive when linked directly to a compatible dedicated audio transmitter 4 MUTE LED This LED will illuminate when audio output is muted 5 CH CH Buttons Press these buttons to increase or decrease the streaming channel used to receive audio from the local network Note If only one channel is detected the channel number will not change 6 MUTE Button Press to toggle between muting and unmuting the audio ...

Page 9: ...serial controllable device with a 3 pin adapter cable for the reception of RS 232 signals from a compatible transmitter 4 LAN POE Port Connect via a Gigabit Ethernet switch to compatible receiver s to transmit data and to a PC laptop to control the unit via WebGUI Note This unit can be powered directly by the connected Gigabit Ethernet switch if it provides PoE 802 3af 5 DC 5V Port Plug the 5V DC ...

Page 10: ...how up indicating their current IP address Note This unit defaults to Auto IP mode The current IP address can be verified using the Device Discovery software By clicking on one of the listed devices you will be presented with the network details of that particular device 1 IP Mode If you choose you can alter the static IP network settings for the device or switch the unit into DHCP mode to automat...

Page 11: ...its own WebGUI interface which may be accessed by opening a standard web browser on a PC and typing in the IP address of the unit you wish to connect to If you do not already know the IP addresses of the units in your system you can discover the IP addresses by using the Device Discovery software Once you have connected to a unit s WebGUI you will be presented with a screen containing multiple tab...

Page 12: ...riety of statistics and information about the operational state of the unit 1 Version Information This window displays detailed information about the current firmware version 2 Update Firmware Provides a way to update the transmitter s firmware Click Choose File to select the firmware update file from the local PC bin format After selecting an appropriate file click the Upload button to begin the ...

Page 13: ...clicking Factory Default The unit may be rebooted without resetting settings by pressing the Reboot button Finally individual Telnet commands may be sent to the unit by using the Console API Command text entry field and pressing Apply Any responses from the unit will be displayed in the Output field ...

Page 14: ...istics The Statistics window shows all available information about the operational status of the unit including current Host ID Name Ethernet information MAC address unicast multicast mode link status and mode ...

Page 15: ...er clicking on Apply please follow the reboot instructions in the WebGUI Note If the IP address is changed then the IP address required for WebGUI access will also change accordingly If the new address is assigned via Auto IP or DHCP it can be verified using the Device Discovery software 1 Channel Setup Use the dropdown to select the broadcast reception channel for the receiver The receiver will o...

Page 16: ...e will cause the unit to immediately begin flashing the PWR and LINK LEDs on the front of the unit to make it easy to find Selecting Hide Me returns the LEDs to their normal behavior This setting is useful when troubleshooting an installation with a large number of units in a rack 3 Casting Mode Allows for the selection of the broadcasting mode used by the receiver Click the Apply button to save c...

Page 17: ... source selection audio output mute unmute analogue audio volume front panel locks and serial control extension configuration Changes made to these settings typically require a reboot of the unit After clicking on Apply please follow the reboot instructions in the WebGUI if necessary ...

Page 18: ...sable either of these lock types for the front panel When the locks are enabled the user can only change settings using the WebGUI or Telnet commands 2 Serial over IP This section provides controls for the Serial over IP extension functionality including enabling disabling serial support and setting the RS 232 data configuration Enable Serial over IP Unchecking this checkbox will completely disabl...

Page 19: ... control and commands may now be entered directly Note 1 If the IP address of the unit is changed then the IP address required for Telnet access will also change accordingly Note 2 This unit defaults to Auto IP mode The current IP address can be verified using the Device Discovery software The default communication port is 23 6 6 Serial and Telnet Commands COMMAND Description and Parameters help S...

Page 20: ...defaults set factory ipconfig default Reset the unit s network settings to the factory defaults set system reboot Reboot the unit set keylock N1 Enable or disable the front panel button key lock feature Available values for N1 ON Key lock enabled OFF Key lock disabled get keylock Show the current front panel button key lock state set audio volume knob lock N1 Enable or disable the front panel volu...

Page 21: ...32 port Available values for N1 300 300 baud 600 600 baud 1200 1200 baud 2400 2400 baud 4800 4800 baud 9600 9600 baud 19200 19200 baud 38400 38400 baud 57600 57600 baud 115200 115200 baud get uart 1 baudrate Show the current baud rate of the RS 232 port set uart 1 stop bit N1 Set the number of stop bits for the RS 232 port Available values for N2 1 1 Stop Bit 2 2 Stop Bits get uart 1 stop bit Show...

Page 22: ...ity of the RS 232 port Available values for N1 0 None 1 Odd 2 Even get uart 1 parity Show the current parity setting of the RS 232 port set ip mode N1 Set the unit s IP address assignment mode Available values for N1 STATIC Static IP mode DHCP DHCP mode FORCE IP Auto IP mode get ip mode Show the current IP address assignment mode get ipconfig Show the unit s current IP configuration information ge...

Page 23: ...5 Netmask get static netmask Show the unit s current static netmask set static gateway N1 Set the unit s static gateway address N1 X X X X X 0 255 Gateway address get static gateway Show the unit s current static gateway address set audio out A mute N1 Enable or disable muting all audio output Available values for N1 ON Muted OFF Unmuted get audio out A mute Show the current mute state of the audi...

Page 24: ...nsmitter to use as it s source Available values for N1 1 Optical input 2 Line input 3 Mic input Note Input selection is only available when linked directly to a compatible dedicated audio transmitter get audio out A route Show the linked transmitter s current audio input source set rx channel N1 Set the Audio over IP AoIP channel to receive N1 0 255 Channel index value get rx channel Show the curr...

Page 25: ...smitter s current audio input to this receiver s audio outputs N1 0 255 Channel index value get tx 1 audio in 1 route rx Show the channel index number of the transmitter whose audio is currently routed to this receiver set tx 1 uart route rx N1 Route the specified transmitter s RS 232 input to this receiver s RS 232 output N1 0 255 Channel index value get tx 1 uart route rx Show the channel index ...

Page 26: ...TICAL LINE IN MIC RS 232 LAN POE TX RX DC 5V Blu ray Player Network Switch Blu ray Player Microphone RS 232 Equipped PC Latop Power Supply Power Supply Powered Speakers Powered Speakers RS 232 Controllable Unit C M Y CM MY CY CMY K CH A320TXRX_Connection_Diagram pdf 1 12 05 2022 11 26 ...

Page 27: ...115200 Power Supply 5V 1 2A DC US EU standards CE FCC UL certified or PoE 802 3af ESD Protection HBM 8kV Air Discharge 4kV Contact Discharge Dimensions W H D 108mm 25mm 108mm Case Only 108mm 25mm 116mm All Inclusive Weight 367g Chassis Material Metal Aluminum Chassis Color Black Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 60 C 4 F 140 F Relative Humidity 20 90 RH Non condens...

Page 28: ... 2 Channels Sampling Rate kHz 32 44 1 48 88 2 96 176 4 192 Bitstream Supported Formats Standard 8 2 2 Analogue Audio Analogue Output Max Audio Level 4Vrms THD N 80dB 0dBFS 1kHz A wt SNR 98dB 0dBFS Frequency Response 3dB 20Hz 20kHz Crosstalk 96dB 10kHz Impedance 499Ω Type Balanced ...

Page 29: ...ented Category 6 cable Cat 7 Category 7 cable CLI Command Line Interface DAC Digital to Analogue Converter dB Decibel DHCP Dynamic Host Configuration Protocol GbE Gigabit Ethernet Gbps Gigabits per second GUI Graphical User Interface IGMP Internet Group Management Protocol IP Internet Protocol kHz Kilohertz LAN Local Area Network LED Light Emitting Diode LPCM Linear Pulse Code Modulation MAC Media...

Page 30: ...E TERM PD Powered Device PoE Power over Ethernet S PDIF Sony Philips Digital Interface Format SNR Signal to Noise Ratio TCP Transmission Control Protocol THD N Total Harmonic Distortion plus Noise VLAN Virtual LAN Ω Ohm ...

Page 31: ......

Page 32: ...CYP UK Ltd Unit 7 Shepperton Business Park Govett Avenue Shepperton Middlesex TW17 8BA Tel 44 0 20 3137 9180 Fax 44 0 20 3137 6279 Email sales cypeurope com www cypeurope com v1 00 ...