background image

Home page: http://www.cypress.com.tw

CYPRESS TECHNOLOGY CO., LTD

20121225 MPM-CPOER80W

Summary of Contents for CPOWER-80W

Page 1: ...CPOWER 80W Adjustable DC Power Supply with 8 Outputs Operation Manual Operation Manual ...

Page 2: ......

Page 3: ...echnology reserves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored in a retrieval system or any of its part translated into any language or computer file in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without expre...

Page 4: ...sh an object of any kind into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To protect t...

Page 5: ...ge Contents 1 4 System Requirements 1 5 Features 2 6 Operation Controls and Functions 3 6 1 Front Panel 3 6 2 Rear Panel 4 6 3 DC Power Cable 4 6 4 OLED Functions 5 6 5 RS 232 Protocols 5 6 6 RS 232 Commands 6 7 Connection Diagram 8 8 Specifications 9 ...

Page 6: ...ff switching functions It can be controlled through on panel buttons or via RS 232 commands It also comes with an OLED display which can show the status of all ports or data for a single port 2 APPLICATIONS Installation usage Control Room Exhibition Hall Outdoor activities exhibition 3 PACKAGE CONTENTS Adjustable DC Power Supply with 8 Outputs 8 Screw Type 3 5mm 2 pole Terminal Block 4 DC Lock Cab...

Page 7: ...with the capability of collecting voltage current variation data in time and using RS 232 protocols it can create tables and charts of historic data Supports adjustment of voltage and current to allow the maximum usage on each channel Supports 12V 6 67A power input Supports overall power consumption up to 80 watts Supports up to 8 power outputs with professional pluggable 2 pole 3 5mm Terminal Blo...

Page 8: ...ion menu press to cycle through and view all the available functions In the main menu page press to select the Channel and Press ENTER to check the values for that channel Once entered press CH or CH to increase decrease the Voltage values between 3 2V 10 2V and press ENTER again to enter the Current Limit page press CH or CH to increase decrease the Current values between 0 10A 3 20A then press R...

Page 9: ...4 1 DC 12V Connect the 12V DC power supply included in the package to the unit and plug the adaptor with its power cord into an AC wall outlet 2 POWER OUT 1 8 Connect power cables to the supplied 3 5mm 2 pole Terminal Blocks Maximum of up to 8 devices 3 SERVICE Reserved for manufacturer use only 4 RS 232 Connect with a D Sub 9pin cable to a a PC laptop for RS 232 control of this system 6 3 DC Powe...

Page 10: ... 0 1 60 Sec Switch ON OFF Timeout Setting 5 30sec 5sec a scale never F W Version x xx xx 6 5 RS 232 Protocols CPOWER 80W REMOTE CONTROL PIN Assignment PIN Assignment 1 NC 1 NC 2 Tx 2 Rx 3 Rx 3 Tx 4 NC 4 NC 5 GND 5 GND 6 NC 6 NC 7 NC 7 NC 8 NC 8 NC 9 NC 9 NC Baud Rate 115200 bps Data Bit 8 bit Parity None Stop Bit 1 bit Flow Control None ...

Page 11: ... 5 0 0 1 scale or 5 2 10 2 0 2 scale Iout Y x x Set Current Limit Y 0 means all channels Y 1 8 means channel 1 8 x x 0 1 3 2 power xxx Set Power Mode xxx on off or sta status valert Y x x Set voltage alert threshold Y 0 All channels 1 8 Channel 1 8 x x 0 1 0 1 scale recordintv Y x Set Interval Timing between current output setting and current voltage in second Y 0 means all channels Y 1 8 meanscCh...

Page 12: ... OLED s menu mode in second x 0 5 10 15 20 25 or 30 version Show Firmware version powerinfo Show the Information of input output and total power Note 1 All RS 232 commands will not execute unless followed by a carriage return Commands are case sensitive 2 Items in brackets mean the status of a command setting can be checked by using a sta command For example To check the Voltage alert threshold fo...

Page 13: ...8 7 CONNECTION DIAGRAM DC 12V 8 7 6 5 POWER OUT 4 3 2 1 SERVICE RS232 Devices to be Powered DC HDMI Splitters Switchers Extenders etc PC Laptop Power Supply RS 232 Cable ...

Page 14: ... 10 3 20 A ESD Protection Human body model 8kV air gap discharge 4kV contact discharge Dimensions 340 mm W 111 mm D 30 H Weight 935 g Chassis Material Metal Silkscreen Color Black Operating Temperature 0 C 40 C 32 F 104 F Storage temperature 20 C 60 C 4 F 140 F Relative Humidity 20 90 RH no condensation Power Consumption 80W Max ...

Page 15: ......

Page 16: ...Home page http www cypress com tw CYPRESS TECHNOLOGY CO LTD 20121225 MPM CPOER80W ...