![CYP CHD-380 Operation Manual Download Page 10](http://html1.mh-extra.com/html/cyp/chd-380/chd-380_operation-manual_2705135010.webp)
Code
Ready State
9
PWR000
PWR001
RDY005
RDY006
RDY006
PWR999
FRZ000
FRZ001
FRZ999
NPO000
NPO001
NPO999
POWER
N/P output
FREEZE
SCAN
ZOOM
Move UP
Move DOWN
Move LEFT
Move RIGHT
power off
power on
Inquire status
NTSC output
PAL output
Inquire status
freeze image off
freeze image on
Inquire status
SCN000
SCN001
SCN999
underscan
overscan
Inquire status
ZOM000
ZOM001
ZOM999
zoom off
zoom on
Inquire status
MVU000
MVU001
MVD000
MVD001
MVL000
MVL001
MVR000
MVR001
SZU000
SZU001
SZD000
SZD001
SZL000
SZL001
SZR000
SZR001
RST000
RST003
PAT000
ARA999
CON999
ARA001~ARA009
CON001~CON063
BRI999
BRI000~BRI255
PAT001
PAT999
FMT000
FMT001
FMT999
ASP000
ASP001
ASP002
ASP999
RST001
RST002
move UP button release
move UP button press
move DOWN button release
move DOWN button press
move LEFT button release
move LEFT button press
move RIGHT button release
move RIGHT button press
Size UP
Size DOWN
Size LEFT
shorter height image button release
shorter height image button press
higher height image button release
higher height image button press
narrower width image button release
narrower width image button press
Size RIGHT
wider width image button release
wider width image button press
PATTERN
test pattern off
test pattern on
Inquire status
Output Format
CV / SV
YsUV
Inquire status
Zoom AREA
zoom area1~ area9
Inquire status
range = 0 ~ 63
Inquire status
ASPECT
CONTRAST
range = 0 ~ 255
Inquire status
BRIGHTNESS
SAT999
SAT000~SAT063
range = 0 ~ 63
Inquire status
SATURATION
FLK999
FLK000~FLK021
range = 0 ~ 21
Inquire status
FLICKER
VER999
VER???
unit firmware version response
inquire unit firmware version
VERSION
aspect is full-screen
aspect is pan&scan
aspect is letterbox
Inquire status
RESET
system reset
reset image position
reset image size
reset video settings
Comment
RDY000
RDY003
RDY007
* Command / Response codes of RS-232 transmission:
* Command / Response codes are the combination of 6 bytes.
* Every command's transmission, scan converter responses the equal codes.
* Only PWR???, VER??? codes are available while unit is on Power-Off status.
* Some functions need time to process.
So you have to wait for "RDY???" code received, then you can do next command.
7
Specifications
Input terminals:
- PC on HD-15
- HDTV or SDTV on 3 RCA (YPbPr or YCbCr)
Input resolutions:
- PC resolution list:
VGA@60Hz up to 140Hz refresh rate
SVGA@60Hz up to 120Hz refresh rate
XGA@60Hz up to 85Hz refresh rate
SXGA@60Hz refresh rate
UXGA@60Hz refresh rate
- HDTV resolution list:
480i & 480p @ 60Hz
576i & 576p @ 50Hz
720p @ 50 & 60Hz
1080i @48, 50 & 60Hz
Output terminals:
Composite video on RCA,
S-Video on mini-din,
Component on 3RCA (YCbCr)
PC pass through on HD-15
HDTV pass through on 3 RCA (YPbPr / YCbCr)
Output system:
NTSC or PAL interlaced video.
YCbCr component.
Controls:
Front panel control, IR remote control,
RS-232 control.
Last memory.
Accessories:
HD-15(male) to HD-15(male) VGA cable x 1
Component video 3 RCA to 3 RCA cable x 1
Video cable x 1
S-Video cable x 1
IR remote control x 1
Application software CD x 1
Power: DC 5V/2A, center positive.
Dimensions: 204(W) x 155(D) x 50(H)mm
Weight: 1 Kgs
RS-232 Software Operation
2
3
13
14
15
16
17
18 19
9
10
11
12
4
6
5
8
7
1
1. Connection Status
2. Power
3. System reset
4. Zoom
5. Magnifier
6. Over/Under scan
7. Prompt
8. Option
9. Close
10. Minimize
11. System tray
12. About
13. Aspect
14. Pan/Position
15. Expand/Size
1. Connection Status: Grey icon means disconnection to CHD-380 unit.
Colored icom means connection to CHD-380 unit.
2. Power: Power on/off
3. System reset: Reset CHD-380 settings to default value.
4. Zoom: Turn zoom on.
4
16. Output Format
17. Screen freeze
18. Video Settings
19. RS-232 Com Port
* PC OS: Windows 98/ME/2000/XP
* Software installation:
1. Place installation CD on CD-ROM drive.
2. Execute setup.exe on installation CD.
3. OS maybe requires to update some files.
Please re-start PC. After starting PC ready, execute setup. exe again.
4. Click taskbar menu (START)->(Programs)->(Scan Converter) to execute
software.
* Main Panel
1
2
1. Zoom Area: Zoom area selection - 1~9.
2. Reset: Reset to zoom area 1.
RS-232 Software Operation
6. Over/Under scan: TV overscan adjustments are "pan" and "expand" ; underscan
adjustments are "position" and "size".
7. Prompt: Operation message.
8. Option: Options of TV System, Panel Skin, Test Pattern, Window-top.
TV System
Panel Skin
Test Pattern
Window on top
9. Close: Terminate application software.
System tray
10. Minimize: Shrink application software to window taskbar.
11. System tray: Shrink application software to system tray.
Click the icon and return to normal window.
Application
software version
Firmware version
5
X1.5
X2.0
Small frame
Refresh
Close
Big frame
5. Magnifier: Turn magnifier on. Only for PC-INPUT.
12. About:
Display software version.
Software Version: Application Software version.
Firmware Version: CHD-380 firmware version.
13. Aspect: Select the screen aspect- Full-> Pan & Scan -> Letterbox
14/15. Position/Pan and Size/Expand adjustments
Position/Pan
Reset
Size/Expand
RS-232 Software Operation
Connection and Installation
16. Output format: Select output format for C-V/S-V or YCbCr.
17. Screen freeze: Still screen.
18. Video settings: Brightness/Contrast/Color/Sharpness adjustments.
6
Positio/Pan Adjustments: Position for underscan, Pan adjustment for overscan.
Size/Expand Adjustments: Size for underscan, Expand for overscan.
Reset: Reset settings to default values.
Reset
Reset: Reset settings to default values.
19. RS232 Communination Port: COM1: or COM2:.
RS-232
C-V
Cr
Cb
Y
S-V
OUTPUTS
HD BYPASS
Y
Pb
Pr
Y
Pb
Pr
HD INPUT
PC BYPASS
PC INPUT
ON
OFF
HD/PC
SELECT
DC 5V 2A
AC Adaptor
NTSC or PAL TV
RS-232
Control
DVHS,DVD
LCD or Monitor
PDP
HDTV