SYSTEM PART NUMBERS 

 
 
 
 
 
 
 
 

 
 

 
 

 

 

 

  

 

 

 

 

 

 

 

 

 

 
 

Part Number 

Number of Output Channels 

IWR-5 One 
IWR-5 Five 

IANT-3 3dBi 

Antenna 

IWPT-SW 

Swivel Adaptor (1/4”BSP) for pressure 

transmitters only 

Part Num ber

Pressure Range

Part Num ber

Transm itter Type

IWPT-G1000-00

0-1 Bar g

IWTTP100A

PT100 6x100mm 1/4"BSP

IWPT-G6000-00

0-6 Bar g

IWTTP150A

PT100 6x150mm 1/4"BSP

IWPT-GM1P9-00

-1-+9 Bar g

IWTTP200A

PT100 6x200mm 1/4"BSP

IWPT-G1002-00

0-10 Bar g

IWTTP250A

PT100 6x250mm 1/4"BSP

IWPT-G1602-00

0-16 Bar g

IWTTP300A

PT100 6x300mm 1/4"BSP

IWPT-CO184-00

-1-+24 Bar g

IWTTP400A

PT100 6x400mm 1/4"BSP

IWPT-G2502-00

0-25 Bar g

IWTTJ200A

J type 6x200mm 1/4"BSP

IWPT-G4002-00

0-40 Bar g

IWTTJ300A

J type 6x300mm 1/4"BSP

IWPT-G1003-00

0-100 Bar g

IWTTJ400A

J type 6x400mm 1/4"BSP

IWPT-G2503-00

0-250 Bar g

IWTTK150A

K type 6x150mm 1/4"BSP

IWPT-G4003-00

0-400 Bar g

IWTTK200A

K type 6x200mm 1/4"BSP

IWPTU-GP015-00

0-15 psi g

IWTTK300A

K type 6x300mm 1/4"BSP

IWPTU-GP030-00

0-30 psi g

IWTTK400A

K type 6x400mm 1/4"BSP

IWPTU-CO446-00 -14.5 to +150 psi g

IWTTUP100A

PT100 6x100mm 1/4"NPT

IWPTU-GP075-00

0-75 psi g

IWTTUP150A

PT100 6x150mm 1/4"NPT

IWPTU-GP100-00

0-100 psi g

IWTTUP200A

PT100 6x200mm 1/4"NPT

IWPTU-CO447-00 -14.5 to +350 psi g

IWTTUP250A

PT100 6x250mm 1/4"NPT

IWPTU-GP150-00

0-150 psi g

IWTTUP300A

PT100 6x300mm 1/4"NPT

IWPTU-GP300-00

0-300 psi g

IWTTUP400A

PT100 6x400mm 1/4"NPT

IWPTU-GP750-00

0-750 psi g

IWTTUJ200A

J type 6x200mm 1/4"NPT

IWPTU-GP1K5-00

0-1500 psi g

IWTTUJ300A

J type 6x300mm 1/4"NPT

IWPTU-GP3K6-00

0-3600 psi g

IWTTUJ400A

J type 6x400mm 1/4"NPT

IWPTU-GP5K8-00

0-5800 psi g

IWTTUK150A

K type 6x150mm 1/4"NPT

IWPTL-G0050-00

0-50mbar G

IWTTUK200A

K type 6x200mm 1/4"NPT

IWPTL-G0100-00

0-100mbar G

IWTTUK300A

K type 6x300mm 1/4"NPT

IWPTL-G0250-00

0-250mbar G

IWTTUK400A

K type 6x400mm 1/4"NPT

IWPTL-G0500-00

0-500mbar G

IWPTL-G0750-00

0-750mbar G

IWPTL-G1000-00

0-1000mbar G

IWPTL-G0500-00

0-500mbar Abs

IWPTL-G0750-00

0-750mbar Abs

IWPTL-G1000-00

0-1000mbar Abs

IWPTLU-GP001-00

0-1 psi g

IWPTLU-GP002-00

0-2 psi g

IWPTLU-GP005-00

0-5 psi g

IWPTLU-GP008-00

0-8 psi g

IWPTLU-GP010-00

0-10 psi g

IWPTLU-GP015-00

0-15 psi g

IWPTLU-GP005-00

0-5 psi Abs

IWPTLU-GP010-00

0-10 psi Abs

IWPTLU-GP015-00

0-15 psi Abs

Pressure  Transmitters

Temperature Transmitters

Summary of Contents for IWR-5

Page 1: ...ument we accept no responsibility for damage injury loss or expense resulting from errors or omissions and reserve the right of amendment without notice This document may not be reproduced in any way without the prior written permission of the company Issue 2 1 September 2018 Cynergy3 Components Ltd 7 Cobham Road Ferndown Ind Est Wimborne Dorset BH21 7PE UK Tel 44 0 1202 897969 email sales cynergy...

Page 2: ...o satisfy FCC RF Exposure requirements for mobile and base station transmission devices a separation distance of 20cm or more should be maintained between the antenna of this device and persons during operation To ensure compliance operation at closer than this distance is not recommended The antenna used for this transmitter must not be co located or operating in conjunction with any other antenn...

Page 3: ...ue outputs representing 0 100 of each of the wireless transmitters connected It also has an alarm output that can be used as a high low loss of signal or low battery alarm As delivered the IWR 5 is configured to receive transmissions from IWPT and IWTT wireless pressure transmitters configured from channel 1 to channel 5 Connections and Configuration Switches Terminal Number Connection 1 Power 0V ...

Page 4: ...1 1 9 1 0 0 0 10 1 0 0 1 11 1 0 1 0 12 1 0 1 1 13 1 1 0 0 14 1 1 0 1 15 1 1 1 0 16 1 1 1 1 Switch 5 and 6 select the number of transmissions which are missed before the Alarm relay output switches to the alarm condition Missed Transmissions 5 6 4 0 0 2 0 1 6 1 0 No Alarm 1 1 Switch 7 and 8 Configure the action of the Alarm Relay output This can also be configured to exact alarm values using the US...

Page 5: ...t 4 20mA and to the right to select 1 5Vdc It is possible to adjust the outputs to match the equipment used to monitor the output or to compensate for any zero or span drift of the transmitters This is achieved by using the pushbuttons PB1 DOWN and PB2 UP and the internal LEDs as outlined here Push both buttons at same time then release to put the unit into zero tare mode starting with Channel 1 L...

Page 6: ... analogue output will stay at the last valid value received from the connected transmitter 4 TROUBLE SHOOTING GUIDE Problem encountered Possible Causes LED 7 doesn t flash The IWR receiver is not connected to a transmitter or the transmitters are out of range Any mA or Voltage Output channel reads zero The IWR receiver output is not wired correctly check wiring and try again If wiring is OK check ...

Page 7: ...U CO446 00 14 5 to 150 psi g IWTTUP100A PT100 6x100mm 1 4 NPT IWPTU GP075 00 0 75 psi g IWTTUP150A PT100 6x150mm 1 4 NPT IWPTU GP100 00 0 100 psi g IWTTUP200A PT100 6x200mm 1 4 NPT IWPTU CO447 00 14 5 to 350 psi g IWTTUP250A PT100 6x250mm 1 4 NPT IWPTU GP150 00 0 150 psi g IWTTUP300A PT100 6x300mm 1 4 NPT IWPTU GP300 00 0 300 psi g IWTTUP400A PT100 6x400mm 1 4 NPT IWPTU GP750 00 0 750 psi g IWTTUJ...

Page 8: ...re 20 to 80 C Outputs x 5 4 20mA current source 1 5 Vdc voltage source Relay 5A rated changeover contact Enclosure Material Light Grey ABS RAL 7035 Weight 285g RF Transmitter Contains FCC W MRF24J40MDME Power Requirements 12 to 32 Vdc Fuse Internal resettable fuse Dimensions 160 x 80 x 57mm L x W x D Mounting Any Orientation Cynergy3 Components Ltd 7 Cobham Road Ferndown Ind Est Wimborne Dorset BH...