background image

WARRANTY

The Dynamco range of Cyclops Security Systems is covered by an extensive two year warranty (parts & accessories one 

year). In the unlikely event of a faulty system Dynamco will either replace or repair the system at no cost during the 2 year 

period. 
The warranty does allow for the following conditions ~
Subject to the conditions stated below, Dynamco Pty Ltd warranty the product to be free from manufacturing defects and 

faulty material within the warranty period stated.
 That the warranty registration has been completed in full at the time of purchase / installation and is produced when 

warranty service is sought
The warranty does not cover general maintenance such as cleaning / adjusting of door, boot, bonnet or any entry point 

switch, nor replacement of consumables items such as transmitter batteries, lighting circuit bulbs / switches. 
The warranty shall be null & void if: - 

Any person other than by an Authorised Cyclops Sales, Service & Installation Centre has repaired the product.
Should a system / part defect become apparent within the warranty period DYNAMCO PTY LTD will repair the product 

free of charge for parts and labour. The warranty does not cover service labour content or mobile service content.
The product has been altered or tampered with in any way, or the serial number altered, defaced or removed.
The defect has been caused by negligence by the owner or their agent / third party.
The product has not been operated correctly, installed by an unauthorised Cyclops installer or has been subjected to 

misuse or undue wear and tear
Siren, control module, remote controls or any other system part are damaged by water.

The warranty does not cover the following costs: -

Transport of the product to and from Cyclops Service Centres.
Insurance of the product whilst in transit to or from the Cyclops Service Centres.
Cost of any service call / labour where the product is found by Cyclops to be in good working order.

The benefits conferred by this Warranty are in addition to all other rights and remedies, which the consumer has conferred 

in law.
“No liability is accepted for any loss from, damage to or inability to use the vehicle to which the system is installed”.

1.
2.

3.
4.
5.

6.

1.
2.
3.

-19-

P355 P375 P375B 385 User - 2008.19   19

16/07/2008   3:20:43 PM

Summary of Contents for PARALYSER 355

Page 1: ...PARAL YSER 355 375 375b 385 USER INSTRUCTIONS Proudly designed and engineered in Australia by Dynamco Pty Ltd CYCL PS VEHICLE SOLUTIONS P355 P375 P375B 385 User 2008 1 1 16 07 2008 3 20 41 PM...

Page 2: ...THIS CARD SHOULD NOT BE LEFT IN YOUR VEHICLE IT MUST BE KEPT IN A SAFE SECURE PLACE 2 CYCL PS VEHICLE SOLUTIONS P355 P375 P375B 385 User 2008 2 2 16 07 2008 3 20 41 PM...

Page 3: ...7 IMMOBILISATION 8 ALARM PROTECTION ZONES 8 DIAGNOSTICS 8 DIAGNOSTIC TABLE 9 EMERGENCY OVER RIDE 9 PIN OVER RIDE PROCEDURE 10 PROGRAMMABLE OPTIONS 11 OPTION CHANGE PROCEDURE 11 PROGRAMMABLE OPTIONS TA...

Page 4: ...re as day to day use of the system only involves pressing the remote control many features of the systems will provide additional convenience for the user Please read this manual to gain a full unders...

Page 5: ...AND DISARMING ALL To arm the system press the main button on the remote control The vehicle indicators will flash twice The red status LED on the dash will flash when the alarm immobiliser is armed To...

Page 6: ...entarily pressing the secondary button on the remote control before pressing the main button The chirp will re enable upon the next operation The siren chirps can be permanently cancelled by changing...

Page 7: ...main button is pressed for more than 2 seconds The panic feature will sound the siren and flash the indicators To cancel the Panic Feature momentarily press the main button once more The panic feature...

Page 8: ...alarm protects the vehicle by monitoring all door bonnet and boot switches as well as listening for the sound of breaking glass Additional sensors can be installed to provide movement detection if req...

Page 9: ...system are lost broken or stolen the immobiliser can be disarmed by use of a security key and the unique 4 digit Personal Identification Number PIN To disable the security system first turn the key i...

Page 10: ...n the 4th flash has extinguished Turn back to ACC position and count 3 flashes switch ignition ON Turn back to ACC position and count 2 flashes switch ignition ON Turn back to ACC position and count 1...

Page 11: ...door this must remain open throughout the whole procedure Switch the ignition key ON a certain number times this number corresponds to the option number Momentarily press the remote control immediatel...

Page 12: ...t Style Horn pulsed Siren constant 13 Arm Disarm audio confirm Enabled Disabled 15 120 Second re lock Enabled Disabled 17 Central Locking Pulse Time 0 8 Second 3 Seconds 19 Change PIN Begin new PIN 21...

Page 13: ...nges The first flash indicates the system is ready to accept a new remote code Press the main button of the new remote control within two seconds to teach system Four indicator flashes indicates succe...

Page 14: ...the vehicle has been disarmed by remote control and the doors remain closed for more than 120 seconds This prevents accidental disarm Option 17 is used to extend the time length of the central lockin...

Page 15: ...r the PIN code of the system follow the standard option change procedure select option 19 The vehicle indicators will flash twice to inform you that the system is ready to accept the new PIN The time...

Page 16: ...eces taking care not to disturb the circuit board Remove the old batteries whilst paying attention to the orientation of the positive and negative terminals Insert new batteries in identical fashion t...

Page 17: ...601 P375 AS NZS 4601 and AS NZS 3749 P375B AS NZS 4601 P385 AS NZS 4601 and AS NZS 3749 Supply Voltage 9VDC 15VDC Current Consumption less than 20mA while armed Country of manufacture China In Dynamco...

Page 18: ...D on dash won t extinguish Try spare remote control Use Emergency PIN to override system and contact nearest Cyclops service centre The remote fails to operate If the remote fails to operate and the L...

Page 19: ...arent within the warranty period DYNAMCO PTY LTD will repair the product free of charge for parts and labour The warranty does not cover service labour content or mobile service content The product ha...

Page 20: ...F VEHICLE VEHICLE REGO MODEL OF UNIT P I N DATE OF MANUFACTURE DATE OF INSTALL WARRANTY PERIOD CONTROL MODULE SIREN REMOTES INSTALLER S NAME AFTER HOURS EMERGENCY PHONE 20 Production pack Version 1 P3...

Reviews: