Installation

Read ‘Safety information’ before installing the fixture.

The fixture is designed for indoor use only and must be used in a dry location with adequate ventilation. 

Ensure that none of the fixture’s ventilation slots are blocked.

Fasten the fixture to a secure structure or surface. Do not stand it on a surface or leave it where it can 

be moved or fall over. If you install the fixture in a location where it may cause injury or damage if it falls, 

secure it as directed in this user manual using a securely anchored safety cable that will hold the fixture if 

the primary fastening method fails.

Fastening the fixture to a flat surface

The fixture can be fastened to a hard, fixed, 

flat

 surface that is oriented at any angle. Ensure that the 

surface and all fasteners used can support at least 10 times the weight of all fixtures and equipment to 

be installed on it.

Fasten the fixture securely. Do not stand it on a surface or leave it where it can be moved or fall over. 

If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed 

below with a securely anchored safety cable that will hold the fixture if the primary fastening method fails.

Mounting the fixture on a truss

The fixture can be clamped to a truss or similar rigging structure in any orientation. When installing the 

fixture hanging vertically down, you can use an open-type clamp such as a G-clamp. When installing in 

any other orientation, you must use a half-coupler clamp that completely encircles the truss chord.

To clamp the fixture to a truss:

1. 

Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment 

to be installed on it.

2.  Block access under the work area.

3.  Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting 

bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through both mounting 

bracket legs and be fastened with a self-locking nut.

4. 

Working from a stable platform, hang the fixture with its clamp on the truss and fasten the clamp 

securely.

5. 

Secure the fixture with a safety cable as directed below.

Summary of Contents for PR-300C

Page 1: ...USER MANUAL PR 300C 300 watts Cool White LED Profile ...

Page 2: ... 6 DMX 512 connection connection between fixtures 6 Art Net Connection 7 Power connection 7 Operation 8 Control Menu Map 8 Control menu 9 Main Menu 9 Addressing 10 Universal DMX Control 10 RDM control 10 Art Net protocol 11 Rotary Knob function 11 Set dimmer curves 12 Zoom 13 DMX Protocol 14 Fixture Cleaning 14 Fuse Replacement 14 Troubleshooting 14 The fixture does not work no light 14 Technical ...

Page 3: ...of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the ...

Page 4: ...4 V1 0 Overview ...

Page 5: ...ll over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed below with a securely anchored safety cable that will hold the fixture if the primary fastening method fails Mounting the fixture on a truss The fixture can be clamped to a truss or similar rigging structure in any orientation When installing the fixture hanging vertically down yo...

Page 6: ... DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected DMX 512 connection with DMX terminator For installations where the DMX cab...

Page 7: ...er Requirements The PR 300C luminaire operates on 100 to 240 volts AC 10 auto ranging The luminaire contains an auto ranging power supply Power linking between fixtures The fixture with powercon in and out socket Connect the power out to the power in socket in the next fixture till all are connected Caution maximum power linking 6 units Connection with the mains Connect the device to the mains wit...

Page 8: ... Net Mask for class C IP address Mode DMX 1 2 3CH DMX channel mode ArtNet Net 000 127 Set Art Net net SubNet 000 015 Set Art Net subnet in Art Net net Universe 000 015 Set Art Net universe in Art Net subnet Channel 1 2 3CH Art Net channel mode Auto Program 001 008 Preset programs Speed 001 009 Programs speed Maunal Brightness 000 255 Dimmer 0 100 Strobe 000 255 Strobe with speed increasing Dimmer ...

Page 9: ...n Timeout 30S Display shut off time Never Screen Brightness 10 100 Display brightness Reset Yes No System reset Reverse Yes No Display reverse 180 degree Control menu The information menu will appear after the fixture is switched on In this menu the following status is displayed Main Menu Press the MENU button to enter the Main Menu interface ...

Page 10: ...have set based on the quantity of control channels of the unit That means changing the settings of one channel will affect only the selected fixture In the case of the PR 300C which is 1 2 3 channels fixture If you set for example the address in the 1 channel mode to channel 2 the device will use the channel 2 for control Note After switching on the device will automatically detect whether DMX 512...

Page 11: ...unning on your PC or light console has to support Art Net protocol Art Net communication protocol is a 10 Base T Ethernet protocol based on the TCP IP Its purpose is to allow transfer of large amounts of DMX 512 data over a wide area using standard network technology Art Net designed by and copyright Artistic Licence Holdings Ltd For more detail explaination of Art Net protocol please referring to...

Page 12: ...5 Rotate the rotary knob to control the dimmer right stop maximum output left stop zero output or strobe right stop maximum strobe left stop no strobe Note Rotary dimmer or strobe function works in information Menu and Mode Manual menu Up Down Enter function The knob can also act as up down and enter function 1 Press the MENU button to enter the main menu interface 2 Right rotation Down left rotat...

Page 13: ...e UP or DOWN button to select Dimmer menu and press ENTER 3 Press DOWN menu and select Mode sub menu 4 Press the UP or DOWN button to select Custom menu and press ENTER 5 Adjust fade in and fade out time to customize yout dimmer curves Time vary from 150 ms to 2230 ms Zoom This function allows you to adjust the beam width of the fixture Step 1 Loosen the zoom buttons on the side of the device Step...

Page 14: ...les from the outside of the fixture with low pressure compressed air 3 Clean the surfaces by wiping gently with a soft clean lint free cloth moistened with a weak detergent solution Do not rub glass surfaces hard lift particles off with a soft repeated press Dry with a soft clean lint free cloth or low pressure compressed air Remove stuck particles with an unscented tissue or cotton swab moistened...

Page 15: ...MMA 5 Dimmer curves 16 bit dimmer Strobe Video flicker free with selectable PWM Intelligent temperature control Silent operation Control protocols Rotary DMX RDM Artnet Control channels 1 2 3 CHs Input voltage AC100 240V 50 60Hz DMX connections 3 pin XLR In Out male and female Power connections PowerCon In Out Dimensions 745 x 294 x 294mm Net weight 8 7 Kg including lens Color Black IP rating 20 O...