background image

6

V1.0

Operation

Control Menu Map

MAIN MENU

LEVEL 1

FUNCTION INSTRUCTION

A001

001-512

DMX address setting, 3CH mode

d001

001-512

DMX address setting, 1CH mode

Slave

Slave mode

Stat

000-255

Dimmer

St01

1-50

Strobe, with speed increasing

Soud

Sound mode

Focus

This function allows you to adjust the focus of the fixture.

Step 1: Loosen the focus knob on the top of the device.

Step 2: Adjust the focus by sliding the back lenshousing forward or backward.

Step 3: Tighten the focus knob.

DMX Protocol

A.xxx(3 CH Mode)

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

CH2

Strobe

000-005: No function
006-255: Strobe with speed increasing

CH3

Dimmer delay & sound

000-025: Dimmer delay on
026-200: Dimmer delay off
251-255: Sound mode

d.xxx(1 CH Mode)

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

Summary of Contents for PR-20W

Page 1: ...USER MANUAL PR 20W Mini portable Warm White LED profile...

Page 2: ...installing the fixture 4 Fastening the fixture to a flat surface 4 Mounting the fixture on a truss 5 Securing with a safety cable 5 Power connection 5 Operation 6 Control Menu Map 6 Focus 6 DMX Protoc...

Page 3: ...the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operati...

Page 4: ...manual using a securely anchored safety cable that will hold the fixture if the primary fastening method fails Fastening the fixture to a flat surface The fixture can be fastened to a hard fixed flat...

Page 5: ...form hang the fixture with its clamp on the truss and fasten the clamp se curely 5 Secure the fixture with a safety cable as directed below Securing with a safety cable Secure the fixture with a safet...

Page 6: ...us of the fixture Step 1 Loosen the focus knob on the top of the device Step 2 Adjust the focus by sliding the back lenshousing forward or backward Step 3 Tighten the focus knob DMX Protocol A xxx 3 C...

Page 7: ...les from the outside of the fixture with low pressure compressed air 3 Clean the surfaces by wiping gently with a soft clean lint free cloth moistened with a weak detergent solution Do not rub glass s...

Page 8: ...resnel lenses 2 Dimmer curves Strobe Track adapters Video flicker free Silent operation Control protocols Rotary DMX Control channels 1 3 CHs Input voltage AC100 240V 50 60Hz Output 20 42V 600mA DC DM...