background image

5

V1.0

Mounting the fixture on a truss

The fixture can be clamped to a truss or similar rigging structure in any orientation. When installing the 

fixture hanging vertically down, you can use an open-type clamp such as a G-clamp. When installing in 

any other orientation, you must use a half-coupler clamp that completely encircles the truss chord.

To clamp the fixture to a truss:

1. 

Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment 

to be installed on it.

2.  Block access under the work area.

3.  Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting 

bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through both mounting 

bracket legs and be fastened with a self-locking nut.

4. 

Working from a stable platform, hang the fixture with its clamp on the truss and fasten the clamp se

-

curely.

5. 

Secure the fixture with a safety cable as directed below.

Securing with a safety cable

Secure the fixture with a safety cable (or other secondary attachment) that is approved for the weight of 

the fixture so that the safety cable will hold the fixture if a primary attachment fails.

Loop the safety cable through the eyebolt in the back of the fixture and around a secure anchoring point. 

Do not loop the safety cable around the fixture’s mounting bracket only, as this will leave the fixture un

-

secured if it separates from the bracket.

Power connection

Power Requirements

The PR-20W  zoom luminaire operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire 

contains an auto-ranging power supply.

Connection with the mains:

Connect the device to the mains with the enclosed power supply cable.

The occupation of the connection cables as below:

Cable color

Connection

International

Brown 

Live

L

Blue 

Neutral

N

Yellow/green

Earth(Ground)

Summary of Contents for PR-20W

Page 1: ...USER MANUAL PR 20W Mini portable Warm White LED profile...

Page 2: ...installing the fixture 4 Fastening the fixture to a flat surface 4 Mounting the fixture on a truss 5 Securing with a safety cable 5 Power connection 5 Operation 6 Control Menu Map 6 Focus 6 DMX Protoc...

Page 3: ...the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operati...

Page 4: ...manual using a securely anchored safety cable that will hold the fixture if the primary fastening method fails Fastening the fixture to a flat surface The fixture can be fastened to a hard fixed flat...

Page 5: ...form hang the fixture with its clamp on the truss and fasten the clamp se curely 5 Secure the fixture with a safety cable as directed below Securing with a safety cable Secure the fixture with a safet...

Page 6: ...us of the fixture Step 1 Loosen the focus knob on the top of the device Step 2 Adjust the focus by sliding the back lenshousing forward or backward Step 3 Tighten the focus knob DMX Protocol A xxx 3 C...

Page 7: ...les from the outside of the fixture with low pressure compressed air 3 Clean the surfaces by wiping gently with a soft clean lint free cloth moistened with a weak detergent solution Do not rub glass s...

Page 8: ...resnel lenses 2 Dimmer curves Strobe Track adapters Video flicker free Silent operation Control protocols Rotary DMX Control channels 1 3 CHs Input voltage AC100 240V 50 60Hz Output 20 42V 600mA DC DM...