7
V1.0
If you are using controllers with this occupation, you can connect the DMX-output of the controller
directly with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers
with other XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture.
Always connect one output with the input of the next fixture until all fixtures are connected.
DMX-512 connection with DMX terminator:
For installations where the DMX cable has to run a long distance or is in an electrically noisy
environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in
preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an
XLR plug with a 120 resistor connected between pins 2 and 3, which is then plugged into the output
XLR socket of the last fixture in the chain.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω
resistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the
last fixture.
Art-Net Connection
Connect the Ethernet inputs of all fixtures with the Ethernet network.
Switch/Router
PC/Controller
Art-Net
Art-Net
Occupation of the RJ45-connection:
FR-300W installs two RJ45 connectors for DMX data transmission. Pin 1 is for data +, Pin 2 for data -,
Pin 7 & 8 for earthing.
1
2
3
4
5
6
7
8
Ground
-
+
NET IN
+
-
Ground
1
2
3
4
5
6
7
8
NET OUT
Power connection
Power Requirements