4 Channels Mode

Function

Function Control

CH2

Green

000-255: 0-100% Green dimmer

CH3

Blue

000-255: 0-100% Blue dimmer

CH4

White

000-255: 0-100% White dimmer

AR2.D

5 Channels Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

CH2

Red

000-255: 0-100% Red dimmer

CH3

Green

000-255: 0-100% Green dimmer

CH4

Blue

000-255: 0-100% Blue dimmer

CH5

White

000-255: 0-100% White dimmer

AR2.S

6 Channels Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

CH2

Red

000-255: 0-100% Red dimmer

CH3

Green

000-255: 0-100% Green dimmer

CH4

Blue

000-255: 0-100% Blue dimmer

CH5

White

000-255: 0-100% White dimmer

CH6

Strobe

000-255: Strobe with speed increasing

HSV

3 Channels Mode

Function

Function Control

CH1

Hue

000-255: 0-100% Hue

CH2

Saturation

000-255: 0-100% 

Saturation

CH3

Value(brightness)

000-255: 0-100% 

Value(brightness)

ID address selection(Stag-12 channels mode)

Each independent DMX address can have up to 66 ID addressed fixtures. An ID address of 0 will activate 

all ID address locations.

CH12 in Stag-12 CH mode is used to select the target ID address.

DMX value

Function

DMX value

Function

DMX

 

value

Function

000-009

ID1-ID66

212

ID23

235

ID46

010-019

ID1

213

ID24

236

ID47

020-029

ID2

214

ID25

237

ID48

030-039

ID3

215

ID26

238

ID49

040-049

ID4

216

ID27

239

ID50

050-059

ID5

217

ID28

240

ID51

060-069

ID6

218

ID29

241

ID52

070-079

ID7

219

ID30

242

ID53

080-089

ID8

220

ID31

243

ID54

Summary of Contents for FR-200F

Page 1: ...USER MANUAL FR 200F 200 watts RGBW powered LED Fresnel...

Page 2: ...a truss 5 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Control Menu Map 6 Addressing 7 Universal DMX Control 7 RDM control 7 DMX Proto...

Page 3: ...s of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation ope...

Page 4: ...eave it where it can be moved or fall over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed in this user manual using a securely anchored...

Page 5: ...cable as directed below Securing with a safety cable Secure the fixture with a safety cable or other secondary attachment that is approved for the weight of the fixture so that the safety cable will...

Page 6: ...l all are connected Caution maximum power linking 8 units Connection with the mains Connect the device to the mains with the enclosed power supply cable The occupation of the connection cables as belo...

Page 7: ...ging the settings of one channel will affect all the fixtures simultaneously If you set a different address each unit will start to listen to the channel number you have set based on the quantity of c...

Page 8: ...olor preset color temp 000 010 No function 011 030 Red 100 Green0 100 Blue 0 031 050 Red 100 0 Green 100 Blue 0 051 070 Red 0 Green 100 Blue 0 100 071 090 Red 0 Green 100 0 Blue 100 091 110 Red 0 100...

Page 9: ...peed CH12 ID address setting 000 009 ID1 ID66 010 019 ID1 020 029 ID2 030 039 ID3 200 209 ID20 210 ID21 211 ID22 255 ID66 ARC 1 3 Channels Mode Function Function Control CH1 Red 000 255 0 100 Red dimm...

Page 10: ...00 White dimmer CH6 Strobe 000 255 Strobe with speed increasing HSV 3 Channels Mode Function Function Control CH1 Hue 000 255 0 100 Hue CH2 Saturation 000 255 0 100 Saturation CH3 Value brightness 000...

Page 11: ...dust and loose particles from the outside of the fixture with low pressure compressed air 3 Clean the surfaces by wiping gently with a soft clean lint free cloth moistened with a weak detergent solut...

Page 12: ...nt temperature control Silent operation PMMA polymethyl methacrylate lens Barn doors included Control protocols DMX RDM Control channels ARC 1 3CH AR1 D 4CH ARC 2 4CH AR2 D 5CH AR2 S 6CH HSV 3CH STAG...

Reviews: