CONFIGURATION & CONNECTORS
2400-31 FEP Maintenance & Support Guide
2-5
Revision 1.0, March 2005
The 600-2400-31-A0 AC unit has two power switches, each switch associated with one of the power
entry modules. AC power switch A enables and disables power entry to power supply A and AC power
switch B enables and disables power entry to power supply B.
2.2.2
FEP Reset Switch
The FEP Reset Switch is a momentary push-button switch that resets the FEP.
2.3
CONNECTORS
2.3.1
Power Connector
There are two power supply connectors on the right hand side of the FEP.
2.3.1.1
DC Power Connectors (600-2400-31-D0)
The DC power connector is military style circular bayonet connector with the contact arrangement and
pin assignment as shown in Figure 2-4. Mating connector part numbers, backshell part numbers and
cable clamp backshell part numbers are as follows:
Figure 2-4. DC Power Connector
Manufacturer
Mating Connector
Backshell
Cable Clamp
Backshell
ITT Cannon
MS 3476 W14 4S
MS 3475 W14 4S
057-0718-002
057-0685-002
Deutsch
MS 3476 W14 4S
MS 3475 W14 4S
94002-14-3014
94003-14-3014
-48 VDC
-48 VDC Return
Ground
A
D
B
C