Power Switch: 

 

Power indicator:

 When the power switch is on, the indicator is lighted green.   

 

Battery Low Voltage Indicator:

 when the voltage of the battery is lower than 6.5V, the 

power indicator will lighted red, reminding the users to change battery. 

 

Range Switch:

 press the button switch to change between H and L Range.                                                                                       

 

Range Indicator:

 indicating the current Range choice. H level: 100A; L level: 10A. 

 

Auto Zero button:

 to make accurate measurement, users need to do zero degaussing 

before measuring to avoid the influence of environment factors like earth magnetic field 

and temperature shift.   

 

Auto Zero Indicator: 

when Auto Zero, the indicator is lighted on and in green and will 

be turned off when the Auto Zero is finished.   

 

Clamp:

 the clamp used for current measurement; the max diameter for the cable is 

12mm.   

 

External Power Supply Plug:

 powered by external DC supply. 

 

Battery Box:

 standard 9V alkaline battery is used. Please turn off the switch and 

disconnect from the conductor under test & oscilloscope when changing battery.   

 

 

Accessories   

 

 

             

 

 

Output Cable (CK-310):1 meter 

 

 

 

Power Supply Adaptor (

CK-612)

DC12V/1.2A 

CYBERTEK

Summary of Contents for CPL8100A

Page 1: ...Shenzhen Zhiyong Electronics Co Ltd www cybertek cn AC DC Current Probe CPL8100A 100A 600kHz CPL8100B 100A 2MHz Shenzhen Zhiyong Electronics Co Ltd CYBERTEK...

Page 2: ...n equipment with fitful voltage range and pollution rate while the probe s test terminal is connected to the other terminals Please do not surpass the safe voltage range if the fundamental insulation...

Page 3: ...th dust and water The probe s upper and lower contact surfaces is made by precise polishing process Please protect this part or the probe could be malfunction When the battery voltage is lower than 6...

Page 4: ...CPL8100A B Brief Summary 2 Summary 4 Introduction about probe and accessories 4 Electronic Characteristics 6 Operating Method 8 Mechanic Characteristics 9 Environment Characteristics 9 Maintenance 9...

Page 5: ...the current value The auto zero function make it easy for the users to operate and it also has power and low voltage indicator as well as overload sound alert The probe can be powered by battery or ex...

Page 6: ...urement users need to do zero degaussing before measuring to avoid the influence of environment factors like earth magnetic field and temperature shift Auto Zero Indicator when Auto Zero the indicator...

Page 7: ...Figure 3 Phase shift DC 65Hz 1 5 DC 65Hz 1 Typical DC linearity The typical DC linearity at H level 0 01V A Figure 4 Rise time CPL8100A 583ns CPL8100B 175ns Max operation current Please refer to volt...

Page 8: ...g voltage V H 0 01V A L 0 1V A DC 100 10 600 600 DC AC peak value 100 10 600 600 AC peak value 100 10 600 600 AC peak to peak value 200 20 1200 RMS CAT III 70 7 7 07 300 300 RMS CAT II 70 7 7 07 600 6...

Page 9: ...the oscilloscope from voltage to current display If user s oscilloscope doesn t have such function user have to manually set the corresponding attenuation ratio for instance if the probe is H level 0...

Page 10: ...contrary the result is negative Adjust the vertical sensitivity of the oscilloscope to get a stable waveform 5 Mechanic Characteristics Size of the front current clamp About 100 20 60mm Size of the b...

Page 11: ...e of the product there can be one check or calibration every year 8 Troubleshoot Problem Reason Treatment No output signal or amplitude is low Power is off Turn on the power Oscilloscope is AC mode Pl...

Page 12: ...Room A1702 Building 4 TianAn Cyber Park HuangGe North Road LongGang District ShenZhen City China Tel 86 400 852 0005 86 755 86628000 Q Q 400 852 0005 Fax 86 755 86620008 Email cybertek cybertek cn Zh...

Reviews: