FCC Notice 

This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant 
to Part 15 of the FCC Rules.    These limits are designed to provide reasonable protection against 
harmful interference in residential installation.    This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 
interference to radio communications.    However, there is no guarantee that interference will not occur in 
a particular installation.    If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures:    (1) Reorient or relocate the receiving 
antenna.    (2) Increase the separation between the equipment and receiver.    (3) Connect the equipment 
into an outlet on a circuit different from that to which the receiver is connected.      (4) Consult the dealer 
or an experienced radio/TV technician for help.      Any special accessories needed for compliance must 
be specified in the instruction.     
 

CAUTION:

    A shielded-type power cord is required in order to meet FCC emission limits and also to 

prevent interference to the nearby radio and television reception.    It is essential that only the supplied 
power cord be used.    Use only shielded cables to connect I/O devices to this equipment.   
 

CAUTION:

    Any changes or modifications not expressly approved by the guarantee of this device could 

void the user’s authority to operate the equipment. 

 

 

 

 

 

For more information, contact us at: 

CyberPower Systems (USA), Inc. 

5555 12

th

 Avenue East, Suite 110 

Shakopee, MN55379 

Tel:  (952) 403-9500 

Fax:  (952) 403-9500 

Email:  

[email protected]

 

Web:  

www.cyberpowersystems.com

 

 

 

Entire contents copyright ©2003 CyberPower Systems, Inc. 

All rights reserved. Reproduction in whole or in part without permission is prohibited. 

PowerPanel™ and PowerPanel Plus™ are trademarks of CyberPower Systems (USA), Inc.

 

 

 

Summary of Contents for OP1250

Page 1: ...User s Manual Utility Series UPS OP850 1250 ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT www cyberpowersystems com support htm ...

Page 2: ...TORS 8 LIMITED WARRANTY AND POWER CONTROL GUARANTEE 9 Thank you for purchasing a CyberPower Systems Product To enjoy all the features and benefits of this Uninterruptible Power System UPS please read and follow all installation and operation instructions completely This UPS is designed to provide guaranteed power protection for connected electronic equipment The accompanying PowerPanel Plus softwa...

Page 3: ...or safety of any life support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humi...

Page 4: ...d not be connected to the UPS Please assure that the total loads of your equipments must be less than the maximum total power load of your UPS 2 Connect your UPS power cord into a two pole three wire grounding receptacle only Please avoid using extension cords and adapter plugs To maintain optimal battery charge leave the UPS plugged in at all times 3 Press the UPS power button to turn it on The P...

Page 5: ...OP850 1250 Guaranteed Uninterruptible Power System 2 ...

Page 6: ...problem exits with the AC outlet such as bad ground missing ground or reversed wiring If this is illuminated the user is advised to disconnect all electrical equipment from the outlet and have an electrician check the outlet to insure proper wiring Circuit Breaker Reset for Overload Protection Circuit breakers provide optimal overload protection When an overload occurs the circuit breaker will swi...

Page 7: ...fire as it may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Release electrolyte is harmful to the skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current an electrical shock Take the following precautions before replacing the battery 1 Remove all watches rings or other metal object...

Page 8: ...re the UPS performs expected runtime REMINDER Batteries are consider HAZARDOUS WASTE and must be disposed of properly Contact your local government for more information about proper disposal and recycling of batteries STORAGE First turn off your UPS and disconnect its power cord from the wall outlet Disconnect all cables connected to the UPS to avoid battery drain To store your UPS for an extended...

Page 9: ...t least one piece of equipment Wait 10 seconds reset the circuit breaker and then turn the UPS on Batteries are discharged Allow the unit to recharge for at least 4 hours Outlets do not provide power to equipment Unit has been damaged by a surge or spike Contact CyberPower Systems at tech cyberpowersystems com The serial cable is not connected Connect the serial cable to the UPS unit and an open s...

Page 10: ...hone FAX Modem Protection RJ11 RJ45 One In One Out Physical Total of UPS Receptacles 4 for UPS 4 for Surge Dimensions cm 31 0 14 1 18 1 Weight kg 12 3 14 2 Battery Sealed Maintenance Free Lead Acid Battery 12V 7 0AHx2 12V 9 0AHx2 Replaceable Yes Typical Recharge Time 8 Hours Warning Diagnostics Indicators Power On Using Battery Buck Boost Wiring Fault Audible Alarms On Battery Low Battery Overload...

Page 11: ... UtilityFailure The UPSis providingbatterypower Therapidbeepsindicatethe batterywillrunoutof charge withinafewminutes Off On Off Off Off Up Two beeps or rapid beeps Overload Occurs inthe Full time SurgeProtection Outlets TurntheUPSoff andunplugatleast one pieceofequipmentfromthe UPS Wait5seconds resetthe circuitbreakerand turntheUPSon Off On Off On Off On Off On Off Set Long Beep Overload Occurs i...

Page 12: ...nly to the extent necessary to comply with such local law If you are an Initial Customer you are asked to read the following terms and conditions carefully before using the Product By using the Product you consent to be bound by and become a party to the Limited Warranty and Power Control Guarantee If you do not agree to the terms and conditions of the Limited Warranty and Power Control Guarantee ...

Page 13: ...ging and shipment CyberPower will inspect and examine the Product within ten 10 days of receipt If the Product is not as warranted CyberPower will repair or replace the Product and return it to you at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if defective within a reasonable time CyberPower will refund to you the full purchase price you paid...

Page 14: ...Product and c none of the limitations or exclusions on warranty coverage apply or than 10 ...

Page 15: ...contact CyberPower identify the Product the Purchase Date and the item s of Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer and the name of the power utility supplier for the location of the Connected Equipment and Request a Return Materials Authorization RMA 4 Pack and ship the product to CyberPower...

Page 16: ...ation or maintenance or use with items or equipment not designed or intended for use with the product 2 As to Connected Equipment the Power Control Guarantee covers only damage within the specific terms of the Power Control Guarantee to Connected Equipment and only up to the applicable aggregate ceiling amount 3 The Power Control Guarantee does not cover damage to Connected Equipment or apply if t...

Page 17: ...onsequential damages so the above limitation may not apply to you DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES CyberPower does not sell the Products for use in high risk activities The Product is not designed or intended for use in hazardous environments requiring fail safe performance including the operation of nuclear facilities aircraft navigation or communicat...

Page 18: ... equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Any special accessories needed for compliance must be specified in the instruction CAUTION A shielded type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television rec...