TECHNICAL SPECIFICATIONS

 

 

 

12

 

 

*)200V are derated by 20%, 208 V are derated by 10%

 

Model 

OL1000EXL 

OL1500EXL 

OL2000EXL

 

OL3000EXL

 

Configuration 

 

Capacity (VA) 

1000VA 

1500VA 

2000VA 

3000VA 

 

Capacity (Watts) 

900W 

1350W 

1800W 

2700W 

 

Form Factor 

Tower 

 

Energy-saving Technology 

Yes, ECO Mode

 

Efficiency > 93% 

Input 

 

Input Voltage Range 

 

120~139Vac  for    0~  60% Load 

 

140~159Vac   for    0~  70% Load 

 

160~179Vac  for    0~  80% Load 

 

180~189Vac  for    0~  90% Load 

 

190~280Vac  for    0~100% Load 

 

Input Frequency Range 

40~70Hz 

 

Input Power Factor 

0.99 

 

Cold Start 

Yes 

Output 

 

Output Waveform 

Sine wave 

 

Output Voltage* 

200, 208, 220, 230, 240Vac (Configurable) ±2% 

 

Output Frequency 

50 / 60Hz (Auto-Sensing or Configurable) ±0.25Hz 

 

Transfer Time (Typically) 

0ms 

 

Rated Power Factor 

0.9 

 

Harmonic Distortion 

THD < 3% at Linear Load, < 5% at Non-linear Load 

 

Crest Factor 

3 : 1 

 

ECO Mode Voltage Regulation 

±10%, ±15% (Configurable) 

 

UPS Outlets 

(9) IEC C13 

(8) IEC C13, (1) IEC C19, 

Protection 

 

Surge Protection 

IEC 61000-4-5 Level 3 

 

Phone / Network Protection 

RJ11/RJ45 (One In/One Out) 

 

Overload Protection 

Line Mode

 

105~125% Load for 1 min, 

126~150% Load for 10 sec 

Battery Mode

 105~130% Load for 10 sec,  131~150% Load for 2 sec 

 

Short Circuit Protection 

UPS Output Cut off Immediately or Input Fuse / Circuit Breaker Protection 

Battery 

 

Specifications 

(3) 12V/7AH 

(3) 12V/9AH 

(6) 12V/7AH 

(6) 12V/9AH 

 

Recharge Time (Typically) 

5 hours 

 

Sealed, Maintenance Free 

Yes 

 

Hot-Swappable 

Yes 

Status Indicators 

 

LCD Screen 

Multi-Function LCD Readout that Supports

 

 

Multi-Language Interface,   

(23) Types of Read Out, 

 

(25) Types of Function Setting, 

(5) Event Logs 

 

LED Indicators 

 

Power On (White),   

Line Mode (Green),   

Battery Mode (Yellow), 

 

Bypass Mode (Yellow),    Fault (Red),   

Replace Battery (Red) 

 

Audible Alarms 

Battery Mode, Battery Low, Overload, UPS Fault 

Environment

 

 

Operating Temperature 

32

 to 104

 ( 0

 to 40

 

Operating Relative Humidity 

0 to 90% Non-Condensing 

Management

 

 

On-Device Features 

Start-up Self Test, Auto-Charge, Auto-Restart, Auto-Overload Recovery 

 

Connectivity Ports 

(1) Serial Port (RS232), (1) USB Port, (1) Relay Out 

 

SNMP/HTTP Capable 

(1) Expansion Port (With optional SNMP card) 

Software

 

 

Power Management Software 

PowerPanel

®

 Business Edition 

Physical

 

 

Dimensions 

15.6 x 6.6 x 9.1in. (397 x 167 x 

232mm) 

16.3 x 8.3 x 13.2in. (414 x 212 x 336mm) 

 

Net Weight 

37.4lbs(17.0Kg) 

65.1lbs(29.6Kg) 

68.4lbs(31.1Kg) 

Safety

 

 

Conformance Approvals 

CE, VCCI, BSMI 

Summary of Contents for OL1000EXL

Page 1: ...User s Manual OL1000EXL OL1500EXL OL2000EXL OL3000EXL Cyber Power Systems Inc www cyberpower com K01 0000358 03 ...

Page 2: ... carry out installations CAUTION Do not unplug the unit from AC Power during operation as this will invalidate the protective ground insulation CAUTION To avoid electric shock turn off and unplug the unit before installing the input output power cord with a ground wire Connect the ground wire prior to connecting the line wires CAUTION Do not use an improper size power cord as it may cause damage t...

Page 3: ...lled indoor area free of conductive contaminants Do not install this UPS where excessive moisture or heat is present Please see specifications for acceptable temperature and humidity range CAUTION Never install a UPS or associated wiring or equipment during a lightning storm CAUTION Do not work alone under hazardous conditions CAUTION In case of the risk of electric shock do not remove the top cov...

Page 4: ...lephone fax machine or network device 5 Press the ON OFF switch to turn the UPS on The Power On indicator light will display when activated If an overload is detected an audible alarm will sound and the UPS will continuously emit two beeps per second For resetting the unit unplug some equipment from the outlets Make sure your equipment carries a load current within the unit s safe range refer to t...

Page 5: ...he power supply to equipment connected to NONCRITICAL outlets after a designated period of time 7 Serial Port Serial port provides communication between the UPS and the computer The UPS can control the computer s shutdown during a power outage through the connection while the computer can monitor the UPS and alter its various programmable parameters 8 USB port This is a connectivity port which all...

Page 6: ...Copyright 2017 Cyber Power Systems Inc BASIC OPERATION 5 OL1000EXL OL1500EXL OL2000EXL OL3000EXL ...

Page 7: ...Y Red Battery will soon need to be replaced due to insufficient runtime LCD SCREEN UPS STATUS LCD Screen UPS Status Description Line Mode UPS is operating in Line Mode Battery Mode UPS is operating in Battery Mode Bypass Mode UPS is operating in Bypass Mode Manual Bypass UPS is operating in Manual Bypass ECO Mode UPS is operating in ECO Economy Mode BUTTON OPERATION Button Operation Description ON...

Page 8: ...ays the Input Voltage I P Freq XX XHz Displays the Input Frequency O P Load XXX Displays the Output Load as a Percentage of Maximum load O P Amp X XA Displays the Output Current O P Watt XXXXXW Displays the Output Wattage O P VA XXXXXVA Displays the Output VA Load Energy XXXX XKWh Display UPS Load Energy Consumption BAT Volt XXX XV Displays the Battery Voltage BAT Cap XXX Displays the Estimated Pe...

Page 9: ... button to select the Language submenu 6 Press the and buttons to scroll to the language that you want to select You may be prompted to save the selection if so press the ENTER button to save the setting 7 Press the ESC button to cancel or return to previous LCD menu LCD SETTINGS CONFIGURATION There are 25 UPS settings that can be configured by the user 1 Press the ENTER button to activate the MAI...

Page 10: ...lish Español Spanish Français French Deutsch German English Generator Mode 2 Disable Enable Disable Communication Disable Enable Enable Dry Relay Set I P Power Fail Battery Low Summary Alarm UPS On Bypass UPS Fail I P Power Fail Converter Mode 3 Converter Off O P Freq 50Hz O P Freq 60Hz Converter OFF Screen Saver Disable 1 Minutes 5 Minutes 5 minutes Clear Event Log Activate None Button OFF LOCK D...

Page 11: ...attery Test portion of the LCD screen and the unit will perform a manual battery test GRAPHICAL LOAD BATTERY CAPACITY DISPLAY 1 Press the ESC button to return to UPS Status 2 Press the and buttons to scroll to the LOAD and BAT Capacity 3 Press the and buttons to scroll to the Charging or Discharging Capacity LOAD and BAT Capacity The LCD screen displays the Load and Battery capacity with a graphic...

Page 12: ...g the UPS from the wall receptacle before servicing the battery CAUTION Only use tools with insulated handles Do not lay tools or metal parts on top of the UPS or battery terminals Replacement Batteries Please refer to the front side of the UPS for the model number of the correct replacement batteries For battery procurement log onto www CPSww com or contact your local dealer Battery Disposal Batt...

Page 13: ...5 Load for 1 min 126 150 Load for 10 sec Battery Mode 105 130 Load for 10 sec 131 150 Load for 2 sec Short Circuit Protection UPS Output Cut off Immediately or Input Fuse Circuit Breaker Protection Battery Specifications 3 12V 7AH 3 12V 9AH 6 12V 7AH 6 12V 9AH Recharge Time Typically 5 hours Sealed Maintenance Free Yes Hot Swappable Yes Status Indicators LCD Screen Multi Function LCD Readout that ...

Page 14: ...s out of range Output Short Output short circuit Your attached equipment may have problems please remove them and check again Over Temperature High temperature sensor activates protection Check the fan for operation and if the ventilation hole has been covered Coldstart Lock UPS is locked to prevent consuming battery power during shipping Plug into utility power for first time operation Autorestar...