TESTING YOUR UPS SYSTEM 

 
Once you have set up your UPS system, you may wish to 
test it.    Make sure that the UPS has been charged for at least 4 hours before performing this test. 

If you are using PowerPanel Plus™: 

1.  With your UPS and computer on, open an application such as notepad. 
2.  Enter some data into the application. 
3.  Unplug the UPS from the AC outlet. 
When a power failure occurs, PowerPanel Plus™ will appear on the screen.    The outlet and battery symbols will change 
to indicate a power failure.    The countdown timer will move towards zero.    When the timer reaches zero, the software 
will begin to save and close any open applications.    The software will auto-assign names to any files that have not been 
previously saved, and then save the file to the 

PCTemp

 folder which is located in the root directory of your 

C drive

 (where 

C

 is the name of your main hard drive).    Once all open files have been saved and closed, PowerPanel Plus™ will shut 

down the operating system.    Once the operating system is shutdown, the UPS will turn off within 90 seconds.    Wait until 
the UPS has turned off before plugging the UPS back into the outlet. 
Once the test has been completed, plug the UPS back into the AC outlet and turn it back on.    You may then restart your 
computer.    Please allow 4 hours for the UPS to recharge before attempting another self-test. 

If you are not using PowerPanel Plus™: 

1.  Have your computer and UPS turned on. 
2.  Unplug the UPS from the wall to simulate a power failure. 
3.  The UPS will begin beeping, indicating a power failure. 
4.  Save and close any open files. 
5.  Shut down the operating system. 
6.  Once the computer system is shutdown, turn the UPS off. 
As the battery discharges, the unit will beep more rapidly, indicating that the battery is nearing discharge.    Once the test 
is complete, plug the UPS back in to the AC outlet and start your computer. Please allow 4 hours for the UPS to recharge 
before attempting another self-test. 
 

 

REPLACING THE BATTERY 

 
Contact your dealer or call the number in this manual for information on battery replacement.    The order numbers for the 
battery are as follows:   

BA-CPS1100AVR

 for CPS1100AVR 

 

CAUTION!

   

Read and follow the 

IMPORTANT SAFETY INSTRUCTIONS

 before servicing the battery.   

Service the 

battery under the supervision of personnel knowledgeable of batteries and their precautions. 

CAUTION

!    Use only the specified type of battery.    See your dealer for replacement batteries. 

CAUTION

!    The battery may present risk of electrical shock.    Do not dispose of battery in a fire, as it may explode.   

Follow all local ordinances regarding proper disposal of batteries. 

CAUTION!

    Do not open or mutilate the batteries.    Released electrolyte is harmful to skin and eyes and may be 

toxic. 

CAUTION! 

 

A battery can present a high risk of short circuit current and electrical shock.     

 
Take the following precautions before replacing the battery: 

1. 

Remove all watches, rings or other metal objects. 

2. 

Only use tools with insulated handles. 

3. 

Do not lay tools or metal parts on top of battery or any terminals. 

4. Wear 

rubber 

gloves 

and 

boots. 

5. 

Determine if the battery is inadvertently grounded.    If inadvertently grounded, remove source of ground.   

CONTACT WITH GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK!   

The likelihood of 

such shock will be reduced if such grounds are removed during installation and maintenance (applicable to 
a UPS and a remote battery supply not having a grounded circuit). 

 

7

Summary of Contents for CPS1100AVR

Page 1: ...User Manual for CPS1100AVR with USB Serial Interface and PowerPanel Plus Software ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT www cyberpowersystems com faqs htm ...

Page 2: ...ot remove the cover secured by star shaped screws No user serviceable parts are inside except for the battery Refer servicing to qualified personnel CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION UPS must be connected to an AC power outlet with fuse or circuit breaker protection Do not plug into an outlet that is not grounded If yo...

Page 3: ...trical equipment from the outlet and have an electrician check the outlet to insure proper wiring 8 AVR Indicator This LED indicates that the UPS is operating in automatic voltage regulation mode 9 Using Battery Indicator This illuminates during a utility failure indicating that the battery is supplying power to the battery power supplied outlets 10 Check Battery This illuminates indicating a weak...

Page 4: ...cords If used the extension cord must be rated for 15 amps DO NOT plug an extension cord surge suppressor or other multiple outlet device into the battery supplied outlets of the product This will cause an overload and will also VOID the warranty 6 Depress the power switch to turn the unit on The power on indicator light will illuminate 7 If an overload is detected an audible alarm will sound and ...

Page 5: ... instructions 6 When the installation is completed remove the floppy disk For Windows NT 1 Click on Start point to Settings and then click Control Panel 2 Double click on the UPS Icon 3 Remove the check mark from the box labeled UPS is installed on and Click OK 4 Acknowledge the message that the UPS is in an unknown state 5 Exit to the desktop then shutdown your computer 6 Turn the UPS off and unp...

Page 6: ...erating normally the final countdown will begin When the countdown reaches zero PowerPanel Plus will save and close any open files and then shut down the operating system in an intelligent and orderly manner 6 Approximate Backup Time This indicator shows the approximate amount of backup time that is available based upon the battery capacity and the load on the system This indicator can appear in r...

Page 7: ...ups and shutdowns 3 Turn On Select the day date and time that you want the computer system to restart Can only be used in conjunction with a scheduled shutdown 4 Delete Delete the selected item from the schedule 5 Add Adds an item to the schedule 6 Cancel This button is used to exit the log window without saving any changes 7 OK This button is used to exit the shutdown window and save any changes ...

Page 8: ...he operating system 6 Once the computer system is shutdown turn the UPS off As the battery discharges the unit will beep more rapidly indicating that the battery is nearing discharge Once the test is complete plug the UPS back in to the AC outlet and start your computer Please allow 4 hours for the UPS to recharge before attempting another self test REPLACING THE BATTERY Contact your dealer or cal...

Page 9: ...tery wires from the battery 8 Install the replacement battery by connecting the red wire to the positive terminal of the battery and connecting the black wire to the negative terminal of the battery 9 Slide the battery back into the compartment 10 Replace the outlet cover and the 6 retaining screws 11 Recharge the unit for 4 8 hours to ensure the UPS performs expected runtime REMINDER Batteries ar...

Page 10: ... On Off Up Long Beep Overload OccursintheBattery power SuppliedOutlets TurntheUPSoffand unplugatleastonepieceofequipmentfrom theUPS Wait5seconds resetthecircuit breakerandturntheUPSon On On Off On Fla sh Off Off On Set None WeakBattery Rechargethebatteryforat least8hours IfCheckBatteryisilluminated contactCyberPowerSystemsforbattery replacementinformation Off Off Off Off Off Set Off SurgeProtectio...

Page 11: ...tional serial port Move the cable to this port The unit is not providing battery power Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the unit PowerPanel Plus is inactive all icons are gray The serial cable is not the cable that was provided with the unit You must use the cable that was included with the unit for the software and the unit to ...

Page 12: ...and therefore entitled coverage under the Limited Warranty and the Power Control Guarantee Registration is not required for Limited Warranty coverage but note if you do not complete a registration card you will be required to provide proof of purchase as described below to have the benefits of this Limited Warranty LIMITED WARRANTY CyberPower warrants to you the Initial Purchaser that the Product ...

Page 13: ... tech cyberpowersystems com within ten 10 days of the event for which you want to make a claim for warranty service 3 When you call write or E Mail identify the Product the Purchase Date and the item s of Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer for the Connected Equipment and the name of the ...

Page 14: ... transmission 3 Damage from any circumstance described as excluded above with respect to the Product 4 Damages from fire flood wind rain rising water or leakage or breakage of plumbing from abuse misuse or alteration of either the Product or the Connected Equipment Exclusion of Consequential and Other Damages The sole and exclusive remedies of the Initial Customer are those provided by the Limited...

Page 15: ...to an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Any special accessories needed for compliance must be specified in the instruction CAUTION A shielded type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception It is ...

Reviews: