background image

   
 

Copyright © 2013 CyberPower Systems, Inc. 

Introduction 

Overview 

The  CyberPower  external  battery  pack  (BP48V45ART2U)  supports  60A  polarized 
plugs, and is designed for variety of CyberPower UPS systems. When combining with 
the  UPS,  the  battery  pack

 

provides  extended  runtime  with  a  48V  DC  external 

connection. Additional parallel-connected battery packs provides the UPS for a longer 
extended runtime operation.

 

Unpacking 

(1)  Battery  Pack,  (2)  Mounting  Brackets,  (12)  (M5x10)  Bracket  Mounting  Screws 
(Includes four spares), (5) (M5x12) Screws/ (5) Washers (Includes one spare for each, 
(2) Rack-mount Handles, (5) (M4x8) Rack-mount Handle Screws (Include one spare), 
(1)  Expansion  Piece  for  Metal  Plate,  (4)  Rubber  Buffer,  (4)  (M4x8)  Rubber  Buffer 
Screws, (7) Screw Hole Dust Covers (Include two spares), (1) Registration Card, (1) 
User’s Manual 

Product Features 

 

1.

  On-board User-replaceable Fuse Cover- User replaceable fuse is easily accessed 

from the rear panel.

 

2.

  Additional Battery Pack Connecter Sockets

 

3.

  Connector Plug for Additional Battery Packs

 

4.

  AC Circuit Protection- Resettable circuit breaker that provides AC input overload 

protection.

 

5.

  AC Output Outlet- This outlet connects to the AC input inlet of additional battery 

packs.

 

6.

  AC Input Inlet- AC power connectivity to wall receptacle.

 

 

 

 

 

 

 

Summary of Contents for BP48V45ART2U

Page 1: ...User s Manual BATTERY PACK BP48V45ART2U CyberPower Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 Phone 952 403 9500 Toll free 877 297 6937 www CPSww com K01 0000284 00...

Page 2: ...OVERVIEW 2 UNPACKING 2 BASIC OPERATION 2 HORIZONTAL INSTALLATION GUIDE 3 VERTICAL INSTALLATION GUIDE 5 BATTERY CONNECTION TO UPS 6 TROUBLE SHOOTING 6 TECHNICAL SPECIFICATIONS 7 CUSTOMER SERVICE 7 PROD...

Page 3: ...5 Washers Includes one spare for each 2 Rack mount Handles 5 M4x8 Rack mount Handle Screws Include one spare 1 Expansion Piece for Metal Plate 4 Rubber Buffer 4 M4x8 Rubber Buffer Screws 7 Screw Hole...

Page 4: ...ounting brackets and all the hardware Follow below steps to complete the installation Step1 Place the Battery Pack in the Racks 1 Use the provided Mounting Bracket Screws 8 to attach the Mounting Brac...

Page 5: ...th numerous battery packs to extend the battery runtime link the output plugs of all except the one that connects to the UPS CAUTION Single AC inlet could only support ten battery packs on limited If...

Page 6: ...the provided Bracket Mounting Screws 2 to connect the Metal Plate with Expansion Piece Then use another four Bracket Screws to attach the Mounting Brackets 2 to the Expansion Metal Plate Secure the R...

Page 7: ...ution The UPS LCD does not perform expected runtime Do not set the UPS to recognize the battery pack s By pressing the display toggle to select functions Then set up the correct battery pack numbers T...

Page 8: ...rPower provides to you Show the Claim Number on the shipping label or include it with the product You must prepay all shipping costs you are responsible for packaging and shipment and you must pay the...

Page 9: ...h the Product 2 Product or Connected Equipment must be properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code without the use of...

Page 10: ...ct If the Product is defective in material or workmanship CyberPower will repair or replace it at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if...

Page 11: ...l interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at...

Reviews: