background image

 

 

Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at 

www.cpsww.com/registration

Registration certifies your product's warranty, confirms your ownership in the event of a product loss or theft and entitles you to free technical 

support. Register your product now to receive the benefits of CyberPower ownership. 

 
 

(SAVE THESE INSTRUCTIONS) 

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. 

Read this manual thoroughly before attempting to unpack, install, or operate your UPS. 

CAUTION!   

To  prevent  the  risk  of  fire  or  electric  shock,  install  in  a  temperature  and  humidity  controlled  indoor  area  free  of  conductive 

contaminants.    (Please see specifications for acceptable temperature and humidity range). 

CAUTION!   

To  reduce  the  risk  of  electric  shock,  do  not  remove  the  cover  except  to  service  the  battery.  Turn  off  and  unplug  the  unit  before 

servicing the batteries. There are no user serviceable parts inside except for the battery. 

CAUTION!   

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. 

CAUTION!   

The

 

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do not plug into an outlet that is not 

grounded.    If you need to de-energize this equipment, turn off and unplug the unit. 

CAUTION!   

To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a computer component. 

CAUTION!

    Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment, 

ANSI/NFPA 75.

 

CAUTION!

    To  reduce  the  risk  of fire,  connect  only  to  a  circuit  provided  with  20  amperes  maximum  branch  circuit  over  current  protection  in 

accordance with the National Electric Code, ANSI/NFPA 70. 

DO  NOT  USE  FOR  MEDICAL  OR  LIFE  SUPPORT  EQUIPMENT!   

CyberPower  Systems  does  not  sell  products  for  life  support  or  medical 

applications.   

DO NOT

 use in any circumstance that would affect operation and safety of life support equipment, any medical applications or 

patient care. 

DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or near an aquarium.

   

Condensation 

from the aquarium can cause the unit to short out. 

DO NOT USE THE UPS ON ANY TRANSPORTATION!   

To reduce the risk of fire or electric shock, do not use the unit on any transportation 

such as airplanes or ships.

 

The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out. 

 

 

 

INTRODUCTION 

Thank you for selecting a CyberPower Systems UPS product. This UPS is designed to provide unsurpassed power protection, operation and 

performance during the lifetime of the product. 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following: 

(a) UPS unit (b) User’s manual (c) USB device cable 

 

*PowerPanel® Personal Edition software is available on our website. Please visit www.cpsww.com and go to the Software Section 
for a free download. 

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

 

1.

  Ensure that the equipment plugged into the UPS does not exceed the UPS unit’s rated capacity. If the rated capacities of the unit are 

exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.     

2.

  There are many factors that can affect the amount of power that your electronic equipment will require.    For optimal system performance 

keep the load below 80% of the unit’s rated capacity. 

HARDWARE INSTALLATION GUIDE 

1.  Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to   

ensure the battery’s maximum charge capacity, it is recommended that you charge the battery   

for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is   

plugged into an AC outlet, the battery will automatically charge whether the UPS is turned on or   

turned off. 

2.  With the UPS unit turned off and unplugged, connect your computer, monitor, and any other peripherals 

requiring battery backup into the battery power supplied outlets. Plug the other peripheral equipment (eg. 

printer, scanner, speakers, etc.) into the full-time surge protection outlets.   

DO NOT plug a laser printer, 

paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large electrical 

device into the “Battery and Surge Protected Outlets”. The power demands of these devices will 

overload and possibly damage the unit. 

3.  To protect a fax, phone, or modem line, connect a telephone cable from the wall jack outlet to the IN jack 

of the UPS. Connect a telephone cable from one of the UPS OUT jacks to the modem port on the 

computer. The other UPS OUT jack can be used to protect a telephone or fax machine. 

4.  Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is   

protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air   

conditioner, refrigerator, copier, etc.). The warranty prohibits the use of extension cords, outlet strips,   

and surge strips in conjunction with the UPS unit. 

5.  Press the power switch to turn the unit on. The Power On indicator light will illuminate green and the unit will “beep” once.   

6.  If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at 

least one piece of equipment from the battery power supplied outlets.    Make sure the circuit breaker is depressed and then turn the UPS on. 

7.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

8.  To store the UPS for an extended period of time, cover it and store with the battery fully charged. While in storage, recharge the battery every 

three months to ensure optimal battery life. 

9.  Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility. 

 

 

 

DESCRIPTION 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. 

Battery and Surge Protected Outlets 

The unit has six battery powered and surge protected outlets to ensure temporary uninterrupted operation of your equipment during a power 

failure. 

(DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large electrical 

device into the “Battery and Surge Protected Outlets.” The power demands of these devices will overload and possibly damage 

the unit.) 

2. 

Full-Time Surge Protection Outlets 

The unit has six surge suppression outlets.   

3. 

Power Switch 

Used as the master on/off switch for equipment connected to the battery power supplied outlets.   

To turn the UPS ON, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - and release after a 

short beep. 

To turn the UPS OFF, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - and release after two 

short beeps. 

4. 

Power On Indicator 

This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes. 

5. 

Mute Button 

Press the button for 2 seconds to enable the audible alarm (beeps once) or disable (beeps twice) the audible alarm.   

6. 

Fault Indicator 

This LED is illuminated if there is a problem with the UPS. 

7.  USB Port   

The USB port allows connection and communication between the USB port on the computer and the UPS unit. 

8. 

Communication Protection Ports 

Communication protection ports will protect any standard modem, fax, or telephone line. (RJ11) 

9. 

Circuit Breaker 

Located on the side of the UPS, the circuit breaker provides overload and fault protection.   

10.  Ground Screw 

     

  The ground screw is used for any equipment that needs a chassis ground connection.

 

11.  Outlets Designed for AC Adapters 

The UPS unit has four widely-spaced outlets. AC power adapters can be plugged into the UPS without overlapping or blocking adjacent 

outlets. 

 

REPLACING THE BATTERY 

 

Replacement of batteries located in an 

OPERATOR ACCESS AREA

1. 

When replacing batteries, replace with the same number of the following battery: CyberPower / RB1270B for AVRG750U; CyberPower / 

RB1290A for AVRG900U. 

2. 

CAUTION! Risk of Energy Hazard, 12V, maximum 9 Ampere-hour battery. Before replacing batteries, remove conductive jewelry such as 

chains, wrist watches, and rings.

 

High energy through conductive materials could cause severe burns. 

3. 

CAUTION! 

  Do not dispose of batteries in a fire. The batteries may explode. 

4. 

CAUTION! 

  Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic. 

CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING 

TO LOCAL REGULATIONS. 

 

TO REPLACE THE BATTERY 

1.  Turn off and unplug all connected equipment. 

2.  Unplug it from the AC power source. 

3.  Turn the UPS upside down. 

4.  Remove the 1 retaining screw. 

5.  Slide the battery compartment cover completely off of the unit. 

6.  Remove the battery from the compartment. 

7.  Disconnect the battery wires from the battery. 

8.  Install the replacement battery by connecting the red wire and black wire to the positive (+) and negative (-) terminal of the battery. 

9.  Put the battery back into the compartment. 

10.  Slide back the battery compartment cover and tighten the retaining screw. 

11.  Charge the unit for 8 hours to fully charge the battery. 

REMINDER:   

Batteries are considered 

HAZARDOUS WASTE

 and must be disposed of properly.    Most retailers that sell lead-acid batteries 

collects used batteries for recycling, as required by local regulations. 

 

 

 

 

 

Problem

 

Possible Cause 

Solution

 

Full-time surge protection outlets 
stop providing power to 
equipment. Circuit breaker 
button is projecting from the side 
of the unit.

 

Circuit breaker has been tripped due 
to an overload. 

Turn the UPS off and unplug at least one piece of 
equipment.    Wait 10 seconds, reset the circuit breaker by 
pressing the button, and then turn the UPS on.

 

The UPS does not perform 
expected runtime. 

Battery not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

Battery is worn out. 

Contact CyberPower Systems about replacement batteries 
at 

[email protected].

   

The UPS will not turn on. 

The on/off switch is designed to 
prevent damage from rapidly turning 
it off and on. 

Turn the UPS off. Wait 10 seconds and then turn the UPS 
on. 

The unit is not connected to an AC 
outlet. 

The unit must be connected to a 120V 60Hz outlet. 

The battery is worn out. 

Contact CyberPower Systems about replacement batteries 
at 

[email protected].

 

Mechanical problem. 

Contact CyberPower Systems at 

[email protected]

The frequency is outside of the 
operating range of 57-63Hz. 

Turn the UPS off. Make sure the frequency range is within 
57-63Hz. Or you can turn the UPS on in battery mode. 

PowerPanel

®

 Personal Edition is 

inactive (all icons are gray). 
 

The USB cable is not connected. 

Connect the USB cable to the UPS unit and an open USB 
port on the back of the computer. 

The USB cable is connected to a 
bad USB port. 

Check for a different USB port and plug the cable in. 

The unit is not providing battery 
power. 

Shutdown your computer and turn the UPS off.    Wait 10 
seconds and turn the UPS back on.    This should reset the 
unit. 

Additional troubleshooting information can be found at “Support” at 

www.CPSww.com

 

 

DEFINITIONS FOR LED INDICATORS & AUDIBLE ALARMS

 

 

 

Power 

 

Fault 

 

Alarm 

CONDITION 

On 

Off 

Off 

Normal 

On* 

Off 

Beep twice   

every 30 seconds 

Utility  Failure- 

The  UPS  is  providing  power  to  battery 

power-supplied outlets from its battery. 

 
 
 
 
 

 

 

 

 

 

AVRG750U / AVRG900U 

User’s Manual 

K01-0000312-00 

BASIC OPERATION 

INSTALLING YOUR UPS SYSTEM 

TROUBLESHOOTING 

IMPORTANT SAFETY INSTRUCTIONS 

 

 

 

PRODUCT REGISTRATION 

 

 

Reviews: