CyberOptics Corporation
155
Other Components
Other Components
This section contains procedures for replacing the following SE505 system components:
●
Leveling Feet
●
Safety Interlock Switch
Replacing the Safety Interlock Switch
This procedure can be performed with access to the front of the machine in production line.
This section shows the procedure performed when the machine is not in production line.
Parts
Safety Interlock Switch
Safety Interlock Key
➢
To replace the safety interlock switch
1. Turn off all electrical power to the system. For more information, refer to the section
2. Open the SE505 hood.
3. Make sure all motion has stopped.
4. Remove the screws to take off the cover to the safety interlock switch.
Figure 113.
Safety Interlock Switch Access
5. Disconnect the six wires in the box.
Caution:
Turn the AC main circuit breaker to OFF to shut down all electrical power to the
SE505 unit before starting any replacement operations. See “
page 59 for this procedure.
i
Note:
For Parts Replacement, contact CyberOptics for part numbers.
Safety interlock switch
detail. Disconnect wires
(steps 4 through 7 on
155) before removing
the switch.