© 2019, CyberData Corporation, ALL RIGHTS RESERVED
931332C
Quick Reference
Quick Reference
931332C
© 2019, CyberData Corporation, ALL RIGHTS RESERVED
Terminal Block Connections
RTFM Button
5.118 [130.00]
2.252 [57.21]
5.118 [130.00]
5.198 [132.03] w/HOLE PL
UG
DIMENSIONS ARE IN INCHES [MILLIMETER]
Call Button
Features
Dimensions (Front and Side View)
Microphone
Hole
Camera
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
*Contacts 1 and 2 on the terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
3
4
1
8
Wire (IN)
Tin Leads
Approx. 1/4” or
6mm
Terminal Block
can accept 16 AWG wire
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws
When the device is operational and linked to a network,
you can use the Reset Test Function Management
(RTFM) button (SW1 [see picture]) to announce the
device’s IP address or restore the device to the factory
default settings.
To announce the device’s current IP address:
•
Press and release the RTFM button within a five
second window.
Note
The device will use DHCP to obtain the new IP
address (DHCP-assigned address or default to
10.10.10.10 if a DHCP server is not present).
To restore the device to factory default settings:
•
Press and hold the RTFM button for longer than five
seconds until you hear the device announce that it is
restoring the factory default settings.
RTFM button (SW1)
Dimensions (Rear View and Mounting Holes)
Side Conduit Mounting Restrictions
1.690
[85.85]
0.869 [22.07]
0.869 [22.07]
3.380 [85.85]
1.690
[42.93]
[42.93]
3.380
Dimensions are in Inches [Millimeter]
ø0.280 [ø7.11]
ø0.854 [ø21.69]
(4 Places)
Sealing Locknut
Compression
1/2" EMT
Connector
on This Side
Rubber Seal
Conduit
1/2" EMT
(Part of the
Locknut
Compression
Connector)
3
1
0.4 I
nch [10mm]
Th
read Depth Not to Ex
ceed
Thread Depth
(Optional, 1 Provided)
Assembly
Hole Plug
Installation Steps:
1) Remove the hole plug assembly from the side of Backbox
then use it to cover the rear conduit hole.
2) Remove the locknut from the EMT compression connector, and
install the provided sealing locknut if the compression connector's
3) Insert the compression connector with the sealing locknut through
the side conduit hole, and then fasten the locknut inside the backbox.
thread depth exceeds 0.4 inch or 10 millimeters.
Make sure the threads do not protrude out more than 0.4 inch or 10 millimeters.
Backbox
2
4
1
4) Insert the EMT conduit into the EMT compression connector and then tighten.
*