background image

© 2019, CyberData Corporation, ALL RIGHTS RESERVED

931332C

Quick Reference 

Quick  Reference 

931332C

© 2019, CyberData Corporation, ALL RIGHTS RESERVED

Terminal Block Connections

RTFM Button

5.118 [130.00]

2.252 [57.21]

5.118 [130.00]

5.198 [132.03] w/HOLE PL

UG

DIMENSIONS ARE IN INCHES [MILLIMETER]

Call Button

Features

Dimensions (Front and Side View)

Microphone 
Hole

Camera

Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*

Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"

*Contacts 1 and 2 on the terminal block are only for 
powering the device from a non-PoE 12VDC power 
source as an alternative to Network PoE power. Use of 
these contacts for any other purpose will damage the 
device and void the product warranty.

3

4

1

8

Wire (IN)

Tin Leads

Approx. 1/4” or

6mm

Terminal Block

can accept 16 AWG wire

Use a 3.17 mm (1/8-inch) flat blade 

screwdriver for the terminal block screws 

When the device is operational and linked to a network, 
you can use the Reset Test Function Management 
(RTFM) button (SW1 [see picture]) to announce the 
device’s IP address or restore the device to the factory
default settings.

To announce the device’s current IP address:

Press and release the RTFM button within a five 

second window.

Note

The device will use DHCP to obtain the new IP 
address (DHCP-assigned address or default to 
10.10.10.10 if a DHCP server is not present).

To restore the device to factory default settings: 

Press and hold the RTFM button for longer than five 

seconds until you hear the device announce that it is 
restoring the factory default settings.

RTFM button (SW1)

Dimensions (Rear View and Mounting Holes)

Side Conduit Mounting Restrictions

1.690

[85.85]

0.869 [22.07]

0.869 [22.07]

3.380 [85.85]

1.690

[42.93]

[42.93]

3.380

Dimensions are in Inches [Millimeter]

ø0.280 [ø7.11]

ø0.854 [ø21.69]

(4 Places)

Sealing Locknut

Compression

1/2" EMT

Connector

on This Side

Rubber Seal

Conduit

1/2" EMT

(Part of the

Locknut

Compression

Connector)

3

1

0.4 I

nch [10mm]

Th

read Depth Not to Ex

ceed

Thread Depth

(Optional, 1 Provided)

Assembly

Hole Plug

Installation Steps:

1) Remove the hole plug assembly from the side of  Backbox

then use it to cover the rear conduit hole.

2) Remove the locknut from the EMT compression connector, and

install the provided sealing locknut if the compression connector's

3) Insert the compression connector with the sealing locknut through

the side conduit hole, and then fasten the locknut inside the backbox.

thread depth exceeds 0.4 inch or 10 millimeters.

Make sure the threads do not protrude out more than 0.4 inch or 10 millimeters.

Backbox

2

4

1

4) Insert the EMT conduit into the EMT compression connector and then tighten.

*

More installation and mounting information 

 is available in the 

Operations Guide