16/38
1
2
3
4
5
6
7
8
½S
S
S
S
S
S
½
S
α
a
α
b
α
c
α
c
α
c
α
c
α
b
α
a
CybTouch 8 P User Manual
S
ep
.
2019
V2.1
Opening (TDC)
When activated, this parameter allows defining the duration during which the beam
moves back up from BDC. This value must be set to allow the operator enough room to
extract its bent part from between the tools.
When this field is deactivated (grayed), the beam moves back all the way up to
its maximum limit switch.
Step bending
Activating this field allows programming a
large radius bend, by entering the value of
the radius and in how many steps we want
to make it.
For the result to be coherent, the
number of bends to realize the angle
must be such that the length of each
segment is greater than half the length
of the V opening of the die.
Dwell time
Allows defining the duration of the dwell time, meaning the time during which the punch
remains at BDC before coming back up.
When this field is deactivated (grayed), the default Dwell Time value defined in
the machine parameters is applied.
Number of parts
The operator can enter here the total amount of parts to be produced. Every time all
the sequences of the program are executed, hence a part is completed, this counter is
updated of one unit (increased or decreased, see
When the amount of parts is reached, a yellow pop-up window signals it to the operator.