8/38
CybTouch 8 P User Manual
S
ep
.
2019
V2.1
Program counter
mode
This parameter allows defining the counting mode of the part counter. When set to
up
,
the counter will count up to the desired number. When set to
down
, the counter will
count from the desired number down to 0.
Materials
Touching
Materials
opens the Materials page, where the default characteristics for each
material can be changed, or a new material can be configured.
The Materials page displays:
•
Material
: Selected material (here
Steel
).
•
Default thickness
for the material.
•
Default sigma
: Default sigma for the material (here
45
).
•
Displayed
: If the material will be available to be selected for use (here
yes
).
•
Predefined thickn.
: Allows defining up to 7 different predefined thicknesses for the
selected material.
•
Thickness min/max
: determines the maximum and minimum accepted thickness for
the selected material.
This page may not be available, depending on the machine parameters’
configuration. To be allowed to access the Materials page, a level 2 password is
required.
Three predefined default materials are available (steel, stainless steel, aluminum), but
others can be added.
To add a material:
1. Touch
Material
and select a non-configured material (Mater X) from the list.
2. Enter the new material’s characteristics.
3. Touch the name (Mater X) to display the keyboard and enter the name of the new
material.