Instruction Manual
FO SERIAL
Page 4
Convention, range of product and options
Several versions of the unit differ from the following characteristics:
The type of Terminal interface: V28, V11, V35.
The type of power supply: 110 / 230 Vac internal, 24-48 Vdc
The type of packaging: stand alone enclosure or rack mountable card
The type of optical Fibre: Multimode 820 (1300 nm option), Single mode 1310 and 1550 nm connector ST, SC, SFP ( FC in option )
These different versions are summarized on the following table. The same designations will be used throughout this manual to identify the
differences between versions when applicable.
Version
Interface
FO SE11-mmcz
X21-V11
FO SE35-mmcz
V35
FO SE28-mmcz
V28 / RS232
The variants mmcz are:
Variant
MM
C
Z
Multimode 820 nm
Multimode 1300 nm (option)
Single mode Led 1310 nm
Single mode Laser 1310 nm
Single mode Laser 1550 nm
SFP connector
M8
M3
SL
Z3
Z5
SFP
Connector SC
Connector ST
®
Connector FC (option)
SFP connector
C
T
F
Internal power supply 90 – 240 Vac
Internal 24-48 Vdc converter
Rack mount card AMS16
I
C
R
ST® is a registered trademark of AT&T
Example: The FO 8011 SLCI is a desktop version with internal 110 / 230 Vac power supply that provides an X21-V11 DTE interface DTE, fibre
optic is Singlemode at 1310 nm with SC connector.
X21-V11 and V35 cables are available as an option:
•
V35: CXR reference CA.601.460
•
X21-V11 (DB15): CXR reference CA.601.461
Important Information
Conformity Statement EC
Manufacturer name:
CXR Anderson Jacobson
Manufacturer address:
rue de l'Ornette - 28410 ABONDANT – France
Product name:
FO-SERIAL
The
CE mark
attests the conformity of this equipment to the main requirements of the R&TTE 1999/05/CEE European community (until June 12
th
2016), and LVD 2014/35/UE – CEM 2014/30/UE (from June 13
th
2016):
-
For the user’s safety: in compliance with the Directive 2006/95/EC (until April 19
th
2016) and Directive 2014/35/UE (from April 20
th
2016)
as per EN.60950 standard
-
For electromagnetic compatibility: in compliance with the Directive 2004/108/EC (until April 19
th
2016) and Directive 2014/30/UE (from
April 20
th
2016) as per EN.55022 and EN.55024 standards.
Optical Fiber:
caution on use with LASER or LED: EN 60825-2
Safety Instructions
The following accesses are referenced as SELV (Safety Low Voltage] in conformity with EN.41003 standards:
•
24-48 VDC Input of the SERIAL desktop unit
•
Control: V24 - RS232 configuration port
•
DTE - V11: V11-X21 interface of the FO 8011, FO SE11
•
DTE - V28 : V28 interface of the FO8028, FO SE28
•
DTE - V35 : V35 interface of the FO8035, FO SE35
Desktop FO SExx I :
The power cord is the main switching element. Thus the mains outlet must be installed close to the equipment and provided easy access. In order
to comply with the safety regulations, it is imperative to use the accessories (power supply and cables) provided with the equipment. When access