CWSI WRA-3 Operating And Installation Instruction Manual Download Page 6

 

P/N IM-WRA-3 Rev. A 

 2012 Commercial Wireless Systems International, LLC. 

Section 2 - Compatibility 

2.1 Compatible Equipment and Accessories 

The following UL Listed RF products are compatible with the WRA-3 annunciator: 

Commercial Wireless Systems International, LLC 
CP-3000A(DA) – Control Panel 
AR-3A - Repeater 
Smoke Detector Model 300 – Photo Electric Smoke Detector with Integral Sounder 
Tandem Smoke Detector Model 301- Photo Electric Tandem Smoke Detector with Integral Sounder 
Smoke Detector Model 302 – Photo Electric Smoke Detector without Sounder 
Pull Station Model 310 – Manual Pull Station 
Fire Transmitter Models - 340(TS) – N.O. EOL Supervised Transmitter 
CO Detector Model 350 – Carbon Monoxide Detector with Integral Sounder 
 

The following antennas are for use with the WRA-3 annunciator: 

Commercial Wireless Systems International, LLC 
Model OM-1 Omni – Isotropic gain 2.5 dBi 
 

 

 
 

 

Section 3 - Installation 

 

3.1 Preparing the Installation Site 

A signal survey must be performed by a factory trained technician or authorized dealer prior to the 
installation of the WRA-3 annunciator. The signal survey determines an acceptable location to mount 

Summary of Contents for WRA-3

Page 1: ...IM WRA 3 Rev A 2012 Commercial Wireless Systems International LLC WRA 3 R LG WIRELESS REMOTE ANNUNCIATOR OPERATING and INSTALLATION INSTRUCTION MANUAL CWSI LLC 10978 N W 53 Street Sunrise Florida 333...

Page 2: ...or a specific application Local testing for suitability of both the proposed site and application is required Unless prohibited by law the liability of CWSI is limited to the cost of the equipment sup...

Page 3: ...n Site 6 3 2 Receiving and Unpacking the Equipment 7 3 3 Installing the WRA 3 Annunciator 7 3 4 The Backup Battery 8 SECTION 4 USER INTERFACES 9 4 1 LEDS 9 4 2 LCD 10 4 3 Sounder 10 4 4 Buttons 10 SEC...

Page 4: ...l Fire Alarm Code and NFPA 70 National Electrical Code The model WRA 3 is a wireless remote annunciator manufactured by CWSI The annunciator was designed and tested to comply with NFPA 72 National Fir...

Page 5: ...MHz Frequency Hopping Spread Spectrum format CRC data validation Rechargeable Lithium battery supplies 24 hour backup time Built in alert sounder Powered by Class 2 transformer 4 line 20 character bac...

Page 6: ...l Sounder Smoke Detector Model 302 Photo Electric Smoke Detector without Sounder Pull Station Model 310 Manual Pull Station Fire Transmitter Models 340 TS N O EOL Supervised Transmitter CO Detector Mo...

Page 7: ...uipment Always attach an OM 1 antenna to the sma connector prior to applying power enrolling or conducting a signal survey with the WRA 3 The WRA 3 annunciator must be enrolled into a CP 3000A DA cont...

Page 8: ...the enclosure The annunciator leds will light sounder will beep and the lcd display will indicate initialization Within one minute the annunciator should enroll and exit initialization If the annunci...

Page 9: ...wrap 5 Connect the battery to the BT1 connector and reset the control panel The battery and charger voltage can be viewed in the voltage information screen These voltages are readings under load Refer...

Page 10: ...ory trouble menus etc needed for the operator to properly respond and interface with the annunciator The backlight will be on continuous during any off normal condition when A C is present During batt...

Page 11: ...annunciator is programmed by inserting a standard sd card which has been programmed with the panel information via the WRA 3 programmer software 5 2 Normal standby When the installation has no off no...

Page 12: ...urs after a trouble is acknowledged if the system has not been reset 5 Press RESET to reset the system back to normal standby Typical trouble screens Pressing ACK STEP will first acknowledge all unack...

Page 13: ...ot received within 200 seconds Possible causes are a missing antenna break in annunciator network communications or component failure in the annunciator Check the annunciator for proper communication...

Page 14: ...eprogramming of the annunciator s 1 A change to any of the editable parameters of any device or repeater on the device edit screen of the CP 3000A DA The checksum will occur after saving the change s...

Page 15: ...ernatively save the file on the computer then copy the file to a formatted sd card The file will automatically be named as annunciator bin Exporting the file Successful file save Insert the sd card wi...

Page 16: ...ce 7 1 Menus The info and maintenance menu provides general annunciator information such as software revision level serial number base code as well as battery and charger voltage It also has options f...

Page 17: ...the SIGNAL SILENCE when on this screen to erase the base code Warning Do not press the SIGNAL SILENCE button unless you are sure you want to erase the base code as no additional confirmation will be...

Page 18: ...ater or CP 3000A DA the annunciator is linked to The next line shows if the survey is good or bad based on a percentage of signal strength read during the survey signal communication A number of 68 or...

Page 19: ...Enrollment 7 F FCC 4 Features 5 Fire Transmitter 6 H Hardware Fault 13 I Installation 7 Introduction 4 L LED 10 Low Battery 13 N NFPA 4 7 O Omni 6 Operating Frequency 5 Operating Humidity 5 Operating...

Reviews: