background image

C.A.R.E 2000

Maintaining Your C.A.R.E. 2000

CLEANING AND CHANGING FILTERS

HOW TO CHANGE THE POST FILTER

NOTE:

 

WHEN CHANGING THE UV BULBS IT IS RECOMMENDED TO REPLACE THE

         POST FILTER UNDER THE OUT FLOW VENTS WHEN THE ACCESS PANEL
         IS OPEN.

HOW TO CHANGE THE ULTRAVIOLET LAMPS

TOOLS REQUIRED:
A phillips screw driver
A cloth or glove (for New Ultraviolet Bulbs)

SAFETY WARNINGS

 

UNPLUG UNIT BEFORE SERVICING.

 

NEVER LOOK DIRECTLY INTO THE ULTRAVIOLET LAMPS WHEN LIT.

1. Open top access panel, 

FIG.7

Remove the 4 corner screws,
carefully lift access panel and gently hang
off side. 

BE CAREFUL NOT TO DISCON

NECT WIRES.

2. Lift shield plate slightly 

FIG 8

.  vertically and

slide forward from middle support bar.

3. Carefully cut the black nylon shipping tie

from around the base of each Ultraviolet
lamp. 

BE CAREFUL NOT TO CUT THE

WHITE LAMP WIRE

FIG.9

 While holding

the lamp socket with one hand, gently pull
the lamp straight out from its socket.

4. Discard the old lamps, place them in a trash

bag and throw them away.

5.

DO NOT TOUCH

 the glass of the New

Ultraviolet lamps with your hands, as the oil
on your skin may alter the performance of
the lamps. Use a cloth or gloves.

6. Reinstall the HEPA + carbon drum with

the pre-filter around it. Push all the way
back  into the inner chamber. The seam of
the pre-filter should face you.

7. Replace rear access panel and only

replace the (2) screws at the bottom of
access panel.

8. Line up top access panel with 4 holes and

replace screws with phillips screwdriver.

STAND UNIT UPRIGHT

AND PLUG INTO WALL OUTLET,

TURN UNIT TO DESIRED SPEED.

1. Peal off Post Filter
2. Place new post filter onto existing

velcro strips

6

FIG.7

FIG.8

FIG.9

Summary of Contents for C.A.R.E. 2000

Page 1: ...n the market Cleans up to 1 500 sq ft area CSA Approved Certi fied for North America Europe Patented Top Flow Design air discharge 5 stages of filtration Operations Manual C A R E Instructions Now I can breathe the air of the new millennium the air my body needs and deserves Thank you T E Grissom Solana Beach CA ...

Page 2: ...eria yeasts and mold are trapped in the HEPA filter and tend to grow Continuous running of the filter is necessary to dry out these organisms and keep growth to a minimum The Ultraviolet system will also keep any microbiologically contaminated air from passing through but the lamps must be replaced once a year to keep the germicidal level effective If for any reason the C A R E 2000 is not run for...

Page 3: ...ts The following chart will help you determine how many air changes your unit will provide in a given space AIR FLOW PATTERN The C A R E 2000 has an adjustable speed setting We recommend that the unit re mains in the low to medium setting speed For maximum number of air changes ACH set the unit to high e z i s m o o R e g a r e v A x h t d i W x h t g n e L t h g i e H t e e F c i b u C r i A f o ...

Page 4: ...ewoneachsideandonthe back of the unit 3 screws total FIG 2 The back screw on top of rear access panel is a shipping screw and does not need to be replaced 2 Gently rest unit label face down DO NOT REST ON WHEELS Remove the 2 shipping screws on the bottom of the unit These screws are for shipping and do not need to be replaced FIG 3 3 Remove 2 screws on the bottom of the rear access panel FIG 4 Pul...

Page 5: ...r changes may be shorter IF THE RED INDICATOR LIGHT REMAINS ON If cleaning or changing the pre filter does not shut off the red indicator light this signal means that the inner HEPA filter needs to be changed Call your distributor and order a HEPA replacement filter HOW TO CHANGE THE HEPA CARBON FILTER 1 UNPLUGTHEUNITBEFORE SERVICING 2 Follow steps 1 to 4 in the HOW TO CLEAN YOUR PRE FILTER sectio...

Page 6: ... shipping tie fromaround the base of each Ultraviolet lamp BE CAREFUL NOT TO CUT THE WHITE LAMP WIRE FIG 9 While holding the lamp socket with one hand gently pull the lamp straight out from its socket 4 Discard the old lamps place them in a trash bag and throw them away 5 DO NOT TOUCH the glass of the New Ultraviolet lamps with your hands as the oil on your skin may alter the performance of the la...

Page 7: ... ELECTRICAL WATTAGE 130 WATTS HERTZ 60 CYCLE AMP 1 AMP FAN MOTOR ASSEMBLY 350 CFM 2500 RPM CENTRIFUGAL BACKWARD INCLINED FAN OF REIN FORCED POLYAMIDE IS STRONGER THAN STEEL WITH MINIMAL VIBRA TION CREATING HIGH AIR FLOW WITH LOWER ELECTRICAL USAGE MOTOR IS A HIGH EFFICIENCY SPLIT CAPACITOR FOR CONTINOUS LONG LIFE DUTY ADJUSTABLE SPEEDS TO GIVE FINELY TUNED AIR CHANGE LOW NOISE AND VIBRATION DURING...

Page 8: ...OR LIABILITIES EXPRESSED OR IMPLIED THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTSAND YOU MAYALSO HAVE OTHER RIGHTS WHICH MAY VARY FROM STATE TO STATE PLEASEFAXTHISWARRANTYORMAILTHEENCLOSEDWARRANTYCARD OR REGISTER ONLINE www cwrenviro com warranty htm CWR ENVIRONMENTAL PRODUCTS 100 CARNEY STREET GLEN COVE NY 11542 TELEPHONE 516 674 2441 FAX 516 674 3788 8 S T R A P Y T N A R R A W R E D N U S L E E...

Page 9: ..._____ _____ Cardholders Name ________________________________________ Signature __________________________________________________ Please allow 2 3 weeks for delivery QTY ITEM PRICE TOTAL CARE 2000 PRE FILTER POST FILTER SET A Check Enclosed Money Order Enclosed Mastercard Visa Discover AmEx CARBON HEPA DRUM COMPLETE REPLACEMENT PK A B C ULTRAVIOLET LAMPS B 2 PK Subtotal Shp Hdl NYS Residents 8 5 ...

Reviews: