background image

4

5

7

6

Parts Identification

Preparation

 

for

 

Use     

How

 

to

 

Operate

 

the

 

thermometer

2. The last memory is displayed

.

3. You will hear 2 beeps with the 

measuring scale

 

shown as

 

Figure 4.

Last

 

memory

Waiting

Waiting

Ready for next

measurement

How

 

to

 

Operate

 

the

 

thermometer

3. Install 2 new "AAA" batteries into

 

the 

battery compartment matching

 

correct polarities. 

4. Replace the battery cover

 

securely.

Preparation

 

for

 

Use     

LCD  Display

POWER

Button

Battery  Cover

Probe

1

3

2

What are normal temperature values?

Human body temperature varies from

person to person. Also, a person’s 

body temperature can fluctuate 

throughout the day. Therfore, it is very 

important to know your normal body 

temperature range. Therefore, we 

recommend you measure yourself 

when healthy to establish referenced 

temperatures which will make you feel 

more confident of the measured

temperature readings when ill.

1. Pull the battery cover off in the 

direction shown.

2.Prior to installing new batteries you 

must clean the metal contact ends of 

the batteries and the metal springs 

and contacts for the batteries in the 

battery compartment.

Installing/Replacing the Battery:

CAUTION:

WARNING:

1. Replace both batteries at the same

    time. Do not mix old and new ones.

2. Never mix alkaline, standard (carbon-

    zinc) or rechargeable (nickel-cadmium)

    batteries.

1. Do not dispose of batteries in regular

    household trash, refer to your local

    disposal laws and manage as 

    hazardous waste.

2. Do not recharge, put in backwards, 

    disassemble or dispose of batteries

    in fire.  Doing so may result in 

    explosion, leakage and injury.

1. Press the 

 button to 

turn on 

the unit. A beep sound follows.

POWER

Ready  to  measure

6. If the temperature reading is over 

99.5°F(37.5°C), eight consecutive

 

beeps will be heard to indicate fever

 

alarm. 

  3

  7

  .

  1

37.2  -  37.4 

37.5  

AND UP

98.9  -  99.4

99.5  

AND UP

Green

Yellow

Red

98.8

UP  TO

UP  TO

   Measurement

Temperature in °F

   Measurement

Temperature in °C

Back Light Color

4. Put the thermometer on the temple.

  It will beep one time to present

  measurement completion.

5. The display will light according to the

     reading.  Please refer to table below.

7. Once the measurement is done, you will 

    hear 2 beeps indicating the reading has 

    been recorded and it is ready to take the 

    next measurement.  However, we do not 

    recommend consecutive measurements.

8. Turn off the unit by pressing the

POWER button, or the unit will

automatically turn off (and beep)  

after 1 minute of inactivity.

Switching between Fahrenheit and

Centigrade Scale:

You can switch between °F 

and

 °C scales.

Within 3 seconds after turning on the 

device, again press and hold the 

POWER button.  The display will show 

“CH” with “°F” or “°C”.  

°

F  Mode

°

C  Mode

Summary of Contents for KD-2220

Page 1: ...INSTRUCTION MANUAL 0197 Digital Temple Thermometer Model KD 2220 IMPORTANT Read instruction manual before using themometer ...

Page 2: ...I 1 Install batteries into the thermometer making sure the polarity is correct 2 Press and release the POWER button Unit will beep once Wait until it beeps again twice and only F shows in the display Do not place the probe to the temple before the 2 beeps or while the hour glass is still displayed 3 Place and hold the thermometer probe firmly to the skin at the temple wait several seconds for the ...

Page 3: ...ut adult supervision 6 Do not drop or expose thermometer to electric shock as this may adversely affect its performance 7 The thermometer is not waterproof Do not immerse it in water or liquid of any kind 8 To ensure correct readings wait at least 2 minutes between continuous measurements for the thermometer to return to room temperature 9 Do not use the thermometer around flammable materials 10 S...

Page 4: ...ressure varies from person to person During the day it can range from 95 9 F to 100 0 F 35 5 to 37 8 C For some people there can be a difference be tween their temple and body temp We recommend learning what your normal temple temperature is while healthy so you can detect an elevated one when you become ill For accuracy be sure to measure the same area of the temple each time 16 Avoid taking a me...

Page 5: ...know your normal body temperature range Therefore we recommend you measure yourself when healthy to establish referenced temperatures which will make you feel more confident of the measured temperature readings when ill 1 Pull the battery cover off in the direction shown 2 Prior to installing new batteries you must clean the metal contact ends of the batteries and the metal springs and contacts fo...

Page 6: ...tteries at the same time Do not mix old and new ones 2 Never mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries 1 Do not dispose of batteries in regular household trash refer to your local disposal laws and manage as hazardous waste 2 Do not recharge put in backwards disassemble or dispose of batteries in fire Doing so may result in explosion leakage and injury ...

Page 7: ... If the temperature reading is over 99 5 F 37 5 C eight consecutive beeps will be heard to indicate fever alarm 37 1 37 2 37 4 37 5 AND UP 98 9 99 4 99 5 AND UP Green Yellow Red 98 8 UPTO UPTO Measurement Temperature in F Measurement Temperature in C Back Light Color 4 Put the thermometer on the temple It will beep one time to present measurement completion 5 The display will light according to th...

Page 8: ...ent However we do not recommend consecutive measurements 8 Turn off the unit by pressing the POWER button or the unit will automatically turn off and beep after 1 minute of inactivity Switching between Fahrenheit and Centigrade Scale You can switch between F and C scales Within 3 seconds after turning on the device again press and hold the POWER button The display will show CH with F or C F Mode C...

Page 9: ...e most recent memory is shown then release 3 Press and release the button again and again to scroll through the remaining previous memories Etc 4 When you are finished viewing stored memories discontinue pressing the button After a short pause you will hear 2 beeps indicating the unit is ready to take a new measurement Ready to measure ...

Page 10: ...ies it is simply an option Oldest memories will automatically be deleted as you take new measurements Removing the batteries will also delete all memories from the unit NOTE ALL memories will be deleted in this process you cannot delete just one single memory 2 While dEL is still displayed press and release the POWER button once more to finish the delete process OFF will show on the display and al...

Page 11: ...unit to readjust to room temperature before taking another measurement If necessary use only a soft cloth to clean the body of the thermometer Avoid using thinner benzene or other harsh cleaners Do not use an abrasive cleanser and NEVER submerge the thermometer in water or any other liquid Remove the batteries if the thermometer will not be used for a long period of time Do not expose the unit to ...

Page 12: ...mometer will power off automatically Please measure again 60 104 F stop measuring The The thermometer has malfunctioned Please contact distributor Indicates a low battery condition Replace with 2 new AAA batteries as soon as possible Message Instruction Replace with 2 new AAA batteries immediately The temperature measured was higher than the specified mea suring range Wait 2 minutes and try again ...

Page 13: ......